fix idrac9 version handling in redfish vmedia boot interface
Fixes the redfish-virtual-media boot interface logic to provide more clarity to a user when an error occurs as Dell iDRAC10s do not work with the present virtual media code, and users should instead use the idrac interface variant. Change-Id: I96642a5e9b65eb08c3c42da3e35f376d5e264fbc Signed-off-by: Julia Kreger <juliaashleykreger@gmail.com>
This commit is contained in:
@@ -683,13 +683,19 @@ class RedfishVirtualMediaBoot(base.BootInterface):
|
|||||||
if m.manager_type == sushy.MANAGER_TYPE_BMC]
|
if m.manager_type == sushy.MANAGER_TYPE_BMC]
|
||||||
if bmc_manager:
|
if bmc_manager:
|
||||||
fwv = bmc_manager[0].firmware_version.split('.')
|
fwv = bmc_manager[0].firmware_version.split('.')
|
||||||
if int(fwv[0]) >= 6:
|
if int(fwv[0]) in [6, 7]:
|
||||||
return
|
return
|
||||||
|
# NOTE(TheJulia) Dell iDRAC10 reverted to 2.x.x.x for versioning
|
||||||
|
# and is also incompatible with the stock virtual media code.
|
||||||
|
# This may be fixed one day, but in the mean time, but the error
|
||||||
|
# provides specific guidance now.
|
||||||
raise exception.InvalidParameterValue(
|
raise exception.InvalidParameterValue(
|
||||||
_("The %(iface)s boot interface is not suitable for node "
|
_("The %(iface)s boot interface is not suitable for node "
|
||||||
"%(node)s with vendor %(vendor)s and BMC version %(fwv)s, "
|
"%(node)s with vendor %(vendor)s and BMC version %(fwv)s, "
|
||||||
"upgrade to 6.00.00.00 or newer or use "
|
"the interface only supports iDRAC9 versions between "
|
||||||
"idrac-redfish-virtual-media instead")
|
"6.0.0.0 and 7.x.x.x. Other versions are incompatible by "
|
||||||
|
"default and you should use the idrac-redfish-virtual"
|
||||||
|
"-media boot interface instead")
|
||||||
% {'iface': task.node.get_interface('boot'),
|
% {'iface': task.node.get_interface('boot'),
|
||||||
'node': task.node.uuid, 'vendor': vendor,
|
'node': task.node.uuid, 'vendor': vendor,
|
||||||
'fwv': bmc_manager[0].firmware_version})
|
'fwv': bmc_manager[0].firmware_version})
|
||||||
|
@@ -481,10 +481,10 @@ class RedfishVirtualMediaBootTestCase(db_base.DbTestCase):
|
|||||||
task.node.properties['vendor'] = "Dell Inc."
|
task.node.properties['vendor'] = "Dell Inc."
|
||||||
|
|
||||||
self.assertRaisesRegex(
|
self.assertRaisesRegex(
|
||||||
exception.InvalidParameterValue, "with vendor Dell Inc.",
|
exception.InvalidParameterValue, "iDRAC9",
|
||||||
task.driver.boot._validate_vendor, task, managers)
|
task.driver.boot._validate_vendor, task, managers)
|
||||||
|
|
||||||
def test__validate_vendor_compatible_with_idrac(self):
|
def test__validate_vendor_compatible_with_idrac9_v6(self):
|
||||||
managers = [mock.Mock(firmware_version='6.00.00.00',
|
managers = [mock.Mock(firmware_version='6.00.00.00',
|
||||||
manager_type=sushy.MANAGER_TYPE_BMC)]
|
manager_type=sushy.MANAGER_TYPE_BMC)]
|
||||||
with task_manager.acquire(self.context, self.node.uuid,
|
with task_manager.acquire(self.context, self.node.uuid,
|
||||||
@@ -505,6 +505,27 @@ class RedfishVirtualMediaBootTestCase(db_base.DbTestCase):
|
|||||||
|
|
||||||
task.driver.boot._validate_vendor(task, managers)
|
task.driver.boot._validate_vendor(task, managers)
|
||||||
|
|
||||||
|
def test__validate_vendor_compatible_with_idrac9_v7(self):
|
||||||
|
managers = [mock.Mock(firmware_version='7.00.00.00',
|
||||||
|
manager_type=sushy.MANAGER_TYPE_BMC)]
|
||||||
|
with task_manager.acquire(self.context, self.node.uuid,
|
||||||
|
shared=True) as task:
|
||||||
|
task.node.instance_info.update(
|
||||||
|
{'kernel': 'kernel',
|
||||||
|
'ramdisk': 'ramdisk',
|
||||||
|
'image_source': 'http://image/source'}
|
||||||
|
)
|
||||||
|
|
||||||
|
task.node.driver_info.update(
|
||||||
|
{'deploy_kernel': 'kernel',
|
||||||
|
'deploy_ramdisk': 'ramdisk',
|
||||||
|
'bootloader': 'bootloader'}
|
||||||
|
)
|
||||||
|
|
||||||
|
task.node.properties['vendor'] = "Dell Inc."
|
||||||
|
|
||||||
|
task.driver.boot._validate_vendor(task, managers)
|
||||||
|
|
||||||
@mock.patch.object(redfish_utils, 'parse_driver_info', autospec=True)
|
@mock.patch.object(redfish_utils, 'parse_driver_info', autospec=True)
|
||||||
@mock.patch.object(deploy_utils, 'validate_image_properties',
|
@mock.patch.object(deploy_utils, 'validate_image_properties',
|
||||||
autospec=True)
|
autospec=True)
|
||||||
|
@@ -0,0 +1,10 @@
|
|||||||
|
---
|
||||||
|
fixes:
|
||||||
|
- |
|
||||||
|
Fixes an issue where the ``redfish-virtual-media`` interface is using version
|
||||||
|
ranges with Dell iDRAC BMCs to report compatibility. Dell has changed the
|
||||||
|
versioning structure for iDRAC10s which triggered the error. That being said,
|
||||||
|
it appears the iDRAC10s are also incompatible as well. The error message
|
||||||
|
now clearly indicates what versions are known to work with the stock
|
||||||
|
redfish virtual media support. Users should instead use the idrac variant
|
||||||
|
boot interface.
|