Merge "Document requirements for BIOS and RAID configuration"
This commit is contained in:
commit
a30cf063d1
@ -295,6 +295,11 @@ BIOS and RAID Configuration
|
||||
BIOS and RAID configuration may require one or more power cycles of the
|
||||
hardware to complete the operation. These will be performed automatically.
|
||||
|
||||
.. note::
|
||||
|
||||
Currently, BIOS and RAID configuration of overcloud hosts is supported for
|
||||
Dell servers only.
|
||||
|
||||
Configuration of BIOS settings and RAID volumes is currently performed out of
|
||||
band as a separate task from hardware provisioning. To configure the BIOS and
|
||||
RAID::
|
||||
@ -307,6 +312,14 @@ properties and root device hints. To perform manual hardware inspection::
|
||||
|
||||
(kayobe) $ kayobe overcloud hardware inspect
|
||||
|
||||
There are currently a few limitations to configuring BIOS and RAID:
|
||||
|
||||
* The Ansible control host must be able to access the BMCs of the servers being
|
||||
configured.
|
||||
* The Ansible control host must have the ``python-dracclient`` Python module
|
||||
available to the Python interpreter used by Ansible. The path to the Python
|
||||
interpreter is configured via ``ansible_python_interpreter``.
|
||||
|
||||
Provisioning
|
||||
------------
|
||||
|
||||
|