Merge "[OVN] Off-path SmartNIC DPU Documentation"
This commit is contained in:
commit
24f863273c
@ -304,6 +304,12 @@ Configuring allow list for PCI devices nova-compute (Compute)
|
||||
Configure neutron-server (Controller)
|
||||
-------------------------------------
|
||||
|
||||
.. note::
|
||||
|
||||
This section does not apply to remote-managed ports of SmartNIC DPU
|
||||
devices which also use SR-IOV at the host side but do not rely on the
|
||||
``sriovnicswitch`` mechanism driver.
|
||||
|
||||
#. Add ``sriovnicswitch`` as mechanism driver. Edit the ``ml2_conf.ini`` file
|
||||
on each controller:
|
||||
|
||||
|
@ -16,3 +16,4 @@ OVN Driver Administration Guide
|
||||
sriov
|
||||
availability_zones
|
||||
routed_provider_networks
|
||||
smartnic_dpu
|
||||
|
205
doc/source/admin/ovn/smartnic_dpu.rst
Normal file
205
doc/source/admin/ovn/smartnic_dpu.rst
Normal file
@ -0,0 +1,205 @@
|
||||
.. _smartnic_dpu:
|
||||
|
||||
===============================
|
||||
Off-path SmartNIC DPUs with OVN
|
||||
===============================
|
||||
|
||||
The purpose of this page is to describe how off-path SmartNIC DPU hardware
|
||||
can be integrated with Neutron when OVN mechanism driver is used. For an
|
||||
in-depth discussion of underlying mechanisms it is recommended to get
|
||||
familiar with the following specifications
|
||||
|
||||
* Neutron `Off-path SmartNIC DPU Port Binding with OVN specification`_;
|
||||
|
||||
* `Nova Integration With Off-path Network Backends specification`_.
|
||||
|
||||
Overview
|
||||
--------
|
||||
|
||||
A class of devices collectively referred to as off-path SmartNIC DPUs introduces
|
||||
an important change to earlier architectures where compute and networking agents
|
||||
used to coexist at the hypervisor host: networking control plane components
|
||||
are now moved to the SmartNIC DPU's CPU side which includes ``ovs-vswitchd``
|
||||
and ``ovn-controller``. The following diagram provides an overview of the
|
||||
components involved::
|
||||
|
||||
┌────────────────────────────────────┐
|
||||
│ Hypervisor │ LoM Ports
|
||||
│ ┌───────────┐ ┌───────────┐ │ (on-board,
|
||||
│ │ Instance │ │ Nova │ ├──┐ optional)
|
||||
│ │(e.g. QEMU)│ │ Compute │ │ ├─────────┐
|
||||
│ │ │ │ │ ├──┘ │
|
||||
│ └───────────┘ └───────────┘ │ │
|
||||
│ │ │
|
||||
└────────────────┬─┬───────┬─┬──┬────┘ │
|
||||
│ │ │ │ │ │
|
||||
│ │ │ │ │ Control Traffic │
|
||||
Instance VF │ │ │ │ │ PF associated │
|
||||
│ │ │ │ │ with an uplink │
|
||||
│ │ │ │ │ port or a VF. │
|
||||
│ │ │ │ │ (used to replace│
|
||||
│ │ │ │ │ LoM) │
|
||||
┌────────────────────────────────────┼─┼───────┼─┼──┼─┐ │
|
||||
│ SmartNIC DPU Board │ │ │ │ │ │ │
|
||||
│ │ │ │ │ │ │ │
|
||||
│ ┌──────────────┐ Control traffic │ │ │ │ │ │ │
|
||||
│ │ App. CPU │ via PFs or VFs ┌┴─┴───────┴─┴┐ │ │ │
|
||||
│ ├──────────────┤ (DC Fabric) │ │ │ │ │
|
||||
│ │ovn-controller├─────────────────┼─┐ │ │ │ │
|
||||
│ ├──────────────┤ │ │ │ │ │ │
|
||||
│ │ovs-vswitchd │ │ │NIC Switch │ │ │ │
|
||||
│ ├──────────────┤ │ │ASIC/FPGA │ │ │ │
|
||||
│ │ Neutron OVN │ │ │ │ │ │ │
|
||||
│ │metadata agent│ │ │ │ │ │ │
|
||||
│ ├──────────────┤Port representors│ │ │ │ │ │
|
||||
│ │ br-int ├═════════════════┤ │ │ │ │ │
|
||||
│ └──────────────┘ └─┼───┬─┬─────┘ │ │ │
|
||||
┌ ┴─ ─ ─ ┐Optional port for │ │ │ │ │ │
|
||||
─┤OOB Port initial NIC switch config │ │ │uplink │ │ │
|
||||
└ ┬─ ─ ─ ┘ │ │ │ │ │ │
|
||||
│ │ │ │ │ │ │
|
||||
└─────────────────────────────────────┼───┼─┼───────┼─┘ │
|
||||
│ │ │ │ │
|
||||
┌──┼───┴─┴───────┼────────┐ │
|
||||
│ │ │ │ │
|
||||
│ │ DC Fabric ├────────┼────────┘
|
||||
│ │ │ │
|
||||
└──┼─────────────┼────────┘
|
||||
│ │
|
||||
│ ┌───┴──────┐
|
||||
│ │ │
|
||||
┌───▼──┐ ┌───▼───┐ ┌────▼────┐
|
||||
│OVN SB│ │Neutron│ │Placement│
|
||||
└──────┘ │Server │ │ │
|
||||
└───────┘ └─────────┘
|
||||
|
||||
Prerequisites
|
||||
-------------
|
||||
|
||||
* OpenStack Yoga or newer;
|
||||
|
||||
* `Open vSwitch`_ >= 2.17;
|
||||
|
||||
* `Open Virtual Network`_ >= 21.12.0;
|
||||
|
||||
* `OVN VIF`_ >= 21.12.0;
|
||||
|
||||
* A SmartNIC DPU with the following characteristics:
|
||||
|
||||
* A NIC that exposes a card serial number via a PCIe VPD capability on its
|
||||
physical or virtual function PCIe endpoints to both the hypervisor host
|
||||
and the DPU host;
|
||||
|
||||
* Exposes the information about representor ports to applications running on
|
||||
the SmartNIC DPU's CPU in a manner supported by one of the `OVN VIF Plug
|
||||
Providers`_.
|
||||
|
||||
Nova configuration
|
||||
------------------
|
||||
|
||||
Hypervisor hosts need to be configured to enable:
|
||||
|
||||
* `Nova PCI passthrough`_ for Nova Compute;
|
||||
|
||||
.. important::
|
||||
|
||||
For more information on other version requirements and limitations check
|
||||
the `SR-IOV section of the Nova networking guide`_.
|
||||
|
||||
* SR-IOV virtual functions on selected physical functions provided by DPUs
|
||||
to the hypervisor hosts.
|
||||
|
||||
In addition to the regular PCI device allow list configuration, the PCI device
|
||||
specification must include the ``remote_managed`` tag as in the following
|
||||
examples:
|
||||
|
||||
* Virtual networks without physical segments;
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[pci]
|
||||
passthrough_whitelist = {"vendor_id": "15b3", "product_id": "101e", "physical_network": null, "remote_managed": "true"}
|
||||
|
||||
* Physical networks (flat, VLAN) with a label:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[pci]
|
||||
passthrough_whitelist = {"vendor_id": "15b3", "product_id": "101e", "physical_network": "dcfabric", "remote_managed": "true"}
|
||||
|
||||
.. note::
|
||||
|
||||
"dcfabric" is an arbitrary physnet name. In order for this to work it must
|
||||
be specified consistenly in Nova config, during OVN configuraton when
|
||||
specifying ``external_ids:ovn-bridge-mappings`` and during Neutron provider
|
||||
network segment creation.
|
||||
|
||||
Auto-Discovery
|
||||
--------------
|
||||
|
||||
When an instance with a ``remote-managed`` port is scheduled to a compute host
|
||||
with a free remote-managed device, it claims it and supplies additional
|
||||
information from that device about the NIC to Neutron so that it knows which
|
||||
OVN chassis needs to handle an representor interface plugging and flow
|
||||
programming. For PCI VFs this additional information includes:
|
||||
|
||||
* A card serial number from the NIC's VPD;
|
||||
|
||||
* PF mac address;
|
||||
|
||||
* VF logical number.
|
||||
|
||||
Neutron uses the card serial number to look up a chassis host name which is
|
||||
needed for port binding to succeed and the rest is used by ``ovn-vif`` to set
|
||||
up the matching representor port.
|
||||
|
||||
As a result, no direct communication or configuration is required between the
|
||||
SmartNIC DPU host and the compute host in order to handle matching of compute
|
||||
hosts to SmartNIC DPUs.
|
||||
|
||||
.. note::
|
||||
|
||||
Multiple DPUs per hypervisor host are possible to use, however, at the time
|
||||
of writing, there is no way to indicate to Nova which VFs to choose via
|
||||
Neutron port object attributes.
|
||||
|
||||
Having the OVN controller expose the SmartNIC DPU serial number is accomplished
|
||||
by providing the serial number via the ``ovn-cms-options`` entry in
|
||||
*external_ids* column of the SmartNIC DPU local *Open_vSwitch* table:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
$ ovs-vsctl set Open_vSwitch . external-ids:ovn-cms-options="card-serial-number=AB0123XX0042"
|
||||
|
||||
Launch an instance with remote managed port
|
||||
-------------------------------------------
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
$ openstack port create \
|
||||
--network network \
|
||||
--vnic-type remote-managed \
|
||||
port1
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
$ openstack server create \
|
||||
--flavor 1 \
|
||||
--nic port-id=port1
|
||||
|
||||
|
||||
.. LINKS
|
||||
.. _Off-path SmartNIC DPU Port Binding with OVN specification:
|
||||
https://specs.openstack.org/openstack/neutron-specs/specs/yoga/off-path-smartnic-dpu-port-binding-with-ovn.html
|
||||
.. _Nova Integration With Off-path Network Backends specification:
|
||||
https://specs.openstack.org/openstack/nova-specs/specs/yoga/approved/integration-with-off-path-network-backends.html
|
||||
.. _Nova PCI passthrough:
|
||||
https://docs.openstack.org/nova/latest/admin/pci-passthrough.html
|
||||
.. _SR-IOV section of the Nova networking guide:
|
||||
https://docs.openstack.org/nova/latest/admin/networking.html#sr-iov
|
||||
.. _Open vSwitch: https://www.openvswitch.org/
|
||||
.. _Open Virtual Network: https://www.ovn.org/
|
||||
.. _OVN VIF: https://github.com/ovn-org/ovn-vif
|
||||
.. _OVN VIF Plug Providers:
|
||||
https://github.com/ovn-org/ovn-vif/tree/main/Documentation/topics/
|
||||
vif-plug-providers
|