Update SR-IOV configuration admin docs
Mellanox ConnectX-3 network adapter family requires additional configuration in Neutron sriov agent when using a dual port adapter. Updated the relevant document to reflect the needed change to allow Neutron sriov agent to properly utilize the generated VFs. Change-Id: I427a497940efe6ff60338390a262d178f834dc8f
This commit is contained in:
parent
d0c322b9e2
commit
f36a3b35f6
@ -63,13 +63,14 @@ The following manufacturers are known to work:
|
|||||||
- Mellanox
|
- Mellanox
|
||||||
- QLogic
|
- QLogic
|
||||||
|
|
||||||
For information on **Mellanox SR-IOV Ethernet ConnectX-3/ConnectX-3 Pro cards**, see
|
For information on **Mellanox SR-IOV Ethernet ConnectX cards**, see:
|
||||||
`Mellanox: How To Configure SR-IOV VFs
|
|
||||||
<https://community.mellanox.com/docs/DOC-1484>`_.
|
|
||||||
|
|
||||||
For information on **QLogic SR-IOV Ethernet cards**, see
|
- `Mellanox: How To Configure SR-IOV VFs on ConnectX-4 or newer <https://community.mellanox.com/s/article/howto-configure-sr-iov-for-connectx-4-connectx-5-with-kvm--ethernet-x>`_.
|
||||||
`User's Guide OpenStack Deployment with SR-IOV Configuration
|
- `Mellanox: How To Configure SR-IOV VFs on ConnectX-3/ConnectX-3 Pro <https://community.mellanox.com/docs/DOC-1484>`_.
|
||||||
<http://www.qlogic.com/solutions/Documents/UsersGuide_OpenStack_SR-IOV.pdf>`_.
|
|
||||||
|
For information on **QLogic SR-IOV Ethernet cards**, see:
|
||||||
|
|
||||||
|
- `User's Guide OpenStack Deployment with SR-IOV Configuration <http://www.qlogic.com/solutions/Documents/UsersGuide_OpenStack_SR-IOV.pdf>`_.
|
||||||
|
|
||||||
Using SR-IOV interfaces
|
Using SR-IOV interfaces
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
@ -482,6 +483,101 @@ Once configuration is complete, you can launch instances with SR-IOV ports.
|
|||||||
|
|
||||||
__ https://docs.openstack.org/nova/latest/admin/pci-passthrough.html#configure-nova-api-controller
|
__ https://docs.openstack.org/nova/latest/admin/pci-passthrough.html#configure-nova-api-controller
|
||||||
|
|
||||||
|
SR-IOV with ConnectX-3/ConnectX-3 Pro Dual Port Ethernet
|
||||||
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
In contrast to Mellanox newer generation NICs, ConnectX-3 family network adapters expose a single
|
||||||
|
PCI device (PF) in the system regardless of the number of physical ports.
|
||||||
|
When the device is **dual port** and SR-IOV is enabled and configured we can observe some inconsistencies
|
||||||
|
in linux networking subsystem.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
In the example below ``enp4s0`` represents PF net device associated with physical port 1 and
|
||||||
|
``enp4s0d1`` represents PF net device associated with physical port 2.
|
||||||
|
|
||||||
|
**Example:** A system with ConnectX-3 dual port device and a total of four VFs configured,
|
||||||
|
two VFs assigned to port one and two VFs assigned to port two.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
$ lspci | grep Mellanox
|
||||||
|
04:00.0 Network controller: Mellanox Technologies MT27520 Family [ConnectX-3 Pro]
|
||||||
|
04:00.1 Network controller: Mellanox Technologies MT27500/MT27520 Family [ConnectX-3/ConnectX-3 Pro Virtual Function]
|
||||||
|
04:00.2 Network controller: Mellanox Technologies MT27500/MT27520 Family [ConnectX-3/ConnectX-3 Pro Virtual Function]
|
||||||
|
04:00.3 Network controller: Mellanox Technologies MT27500/MT27520 Family [ConnectX-3/ConnectX-3 Pro Virtual Function]
|
||||||
|
04:00.4 Network controller: Mellanox Technologies MT27500/MT27520 Family [ConnectX-3/ConnectX-3 Pro Virtual Function]
|
||||||
|
|
||||||
|
Four VFs are available in the system, however,
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
$ ip link show
|
||||||
|
31: enp4s0: <BROADCAST,MULTICAST> mtu 1500 qdisc noop master ovs-system state DOWN mode DEFAULT group default qlen 1000
|
||||||
|
link/ether f4:52:14:01:d9:e1 brd ff:ff:ff:ff:ff:ff
|
||||||
|
vf 0 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
vf 1 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
vf 2 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
vf 3 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
32: enp4s0d1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
|
||||||
|
link/ether f4:52:14:01:d9:e2 brd ff:ff:ff:ff:ff:ff
|
||||||
|
vf 0 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
vf 1 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
vf 2 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
vf 3 MAC 00:00:00:00:00:00, vlan 4095, spoof checking off, link-state auto
|
||||||
|
|
||||||
|
**ip** command identifies each PF associated net device as having four VFs *each*.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
Mellanox ``mlx4`` driver allows *ip* commands to perform configuration of *all*
|
||||||
|
VFs from either PF associated network devices.
|
||||||
|
|
||||||
|
To allow neutron SR-IOV agent to properly identify the VFs that belong to the correct PF network device
|
||||||
|
(thus to the correct network port) Admin is required to provide the ``exclude_devices`` configuration option
|
||||||
|
in ``sriov_agent.ini``
|
||||||
|
|
||||||
|
**Step 1**: derive the VF to Port mapping from mlx4 driver configuration file: ``/etc/modprobe.d/mlnx.conf`` or ``/etc/modprobe.d/mlx4.conf``
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
$ cat /etc/modprobe.d/mlnx.conf | grep "options mlx4_core"
|
||||||
|
options mlx4_core port_type_array=2,2 num_vfs=2,2,0 probe_vf=2,2,0 log_num_mgm_entry_size=-1
|
||||||
|
|
||||||
|
Where:
|
||||||
|
|
||||||
|
``num_vfs=n1,n2,n3`` - The driver will enable ``n1`` VFs on physical port 1,
|
||||||
|
``n2`` VFs on physical port 2 and
|
||||||
|
``n3`` dual port VFs (applies only to dual port HCA when all ports are Ethernet ports).
|
||||||
|
|
||||||
|
|
||||||
|
``probe_vfs=m1,m2,m3`` - the driver probes ``m1`` single port VFs on physical port 1,
|
||||||
|
``m2`` single port VFs on physical port 2 (applies only if such a port exist)
|
||||||
|
``m3`` dual port VFs. Those VFs are attached to the hypervisor. (applies only if all ports are configured as Ethernet).
|
||||||
|
|
||||||
|
The VFs will be enumerated in the following order:
|
||||||
|
|
||||||
|
1. port 1 VFs
|
||||||
|
2. port 2 VFs
|
||||||
|
3. dual port VFs
|
||||||
|
|
||||||
|
In our example:
|
||||||
|
|
||||||
|
| 04:00.0 : PF associated to **both** ports.
|
||||||
|
| 04:00.1 : VF associated to port **1**
|
||||||
|
| 04:00.2 : VF associated to port **1**
|
||||||
|
| 04:00.3 : VF associated to port **2**
|
||||||
|
| 04:00.4 : VF associated to port **2**
|
||||||
|
|
||||||
|
**Step 2:** Update ``exclude_devices`` configuration option in ``sriov_agent.ini`` with the correct mapping
|
||||||
|
|
||||||
|
Each PF associated net device shall exclude the **other** port's VFs
|
||||||
|
|
||||||
|
.. code-block:: ini
|
||||||
|
|
||||||
|
[sriov_nic]
|
||||||
|
physical_device_mappings = physnet1:enp4s0,physnet2:enp4s0d
|
||||||
|
exclude_devices = enp4s0:0000:04:00.3;0000:04:00.4,enp4s0d1:0000:04:00.1;0000:04:00.2
|
||||||
|
|
||||||
SR-IOV with InfiniBand
|
SR-IOV with InfiniBand
|
||||||
~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
@ -513,7 +609,7 @@ you must:
|
|||||||
If ``ebrctl`` does not appear in any of the rootwrap files, add this to the
|
If ``ebrctl`` does not appear in any of the rootwrap files, add this to the
|
||||||
``/etc/nova/rootwrap.d/compute.filters`` file in the ``[Filters]`` section.
|
``/etc/nova/rootwrap.d/compute.filters`` file in the ``[Filters]`` section.
|
||||||
|
|
||||||
.. code-block:: none
|
.. code-block:: ini
|
||||||
|
|
||||||
[Filters]
|
[Filters]
|
||||||
ebrctl: CommandFilter, ebrctl, root
|
ebrctl: CommandFilter, ebrctl, root
|
||||||
|
Loading…