Add doc for ceilometer IPMI agent
Closes-Bug: #1369334 Change-Id: I87bb8c44bf80f2bfc1ed214c7c42e4415689e755 Signed-off-by: Zhai Edwin <edwin.zhai@intel.com>
This commit is contained in:
parent
de267faac9
commit
0ae2f9af57
@ -322,6 +322,33 @@
|
||||
compute section</link> in the <filename>ceilometer.conf</filename> configuration
|
||||
file.</para>
|
||||
</section>
|
||||
<section xml:id="section_telemetry-IPMI-agent">
|
||||
<title>IPMI agent</title>
|
||||
<para>This agent is responsible for collecting IPMI sensor data and Intel Node Manager
|
||||
data on individual compute nodes within an OpenStack deployment. This
|
||||
agent requires IPMI capable node with <application>ipmitool</application> installed, which
|
||||
is a common utility for IPMI control on various Linux distributions.</para>
|
||||
<para>An IPMI agent instance could be installed on each and every compute node
|
||||
with IPMI support, except that the node is managed by Bare metal module for OpenStack
|
||||
and the <option>conductor.send_sensor_data</option> option is set to <literal>true</literal>
|
||||
in the Bare metal module for OpenStack.
|
||||
It is no harm to install this agent on compute node without IPMI or Intel Node
|
||||
Manager support, as the agent checks for the hardware and if none is available, returns empty data.
|
||||
But it is suggested that you install IPMI agent only on IPMI capable node for performance reason.
|
||||
</para>
|
||||
<para>Just like the central agent, this component also does not need a direct database
|
||||
access. The samples are sent via AMQP to the collector.
|
||||
</para>
|
||||
<para>The list of collected meters can be found in the <link xlink:href=
|
||||
"http://docs.openstack.org/developer/ceilometer/measurements.html#ironic-hardware-ipmi-sensor-data">
|
||||
Ironic Hardware IPMI Sensor Data section</link> in the <citetitle>Telemetery Measurements Reference</citetitle>.</para>
|
||||
<note>
|
||||
<para>Do not deploy both IPMI agent and Bare metal module for OpenStack on
|
||||
one compute node. If <option>conductor.send_sensor_data</option> set, this
|
||||
misconfiguration causes duplicated IPMI sensor samples.
|
||||
</para>
|
||||
</note>
|
||||
</section>
|
||||
</section>
|
||||
<section xml:id="section_telemetry-post-api">
|
||||
<title>Send samples to Telemetry</title>
|
||||
@ -776,4 +803,4 @@ sinks:
|
||||
</tbody>
|
||||
</table>
|
||||
</section>
|
||||
</section>
|
||||
</section>
|
||||
|
@ -42,6 +42,13 @@
|
||||
<para>Consumes AMQP messages from other OpenStack services.</para>
|
||||
</listitem>
|
||||
</varlistentry>
|
||||
<varlistentry>
|
||||
<term><systemitem class="service">ceilometer-agent-ipmi</systemitem></term>
|
||||
<listitem>
|
||||
<para>Polls compute node with IPMI support, in order to
|
||||
acquire IPMI sensor data and Intel Node Manager data.</para>
|
||||
</listitem>
|
||||
</varlistentry>
|
||||
<varlistentry>
|
||||
<term><systemitem class="service">ceilometer-collector</systemitem></term>
|
||||
<listitem>
|
||||
@ -213,4 +220,4 @@
|
||||
initiated the action. Further details about alarm handling can be found in
|
||||
<xref linkend="section_telemetry-alarms"/> in this guide.</para>
|
||||
</section>
|
||||