Description of configuration options for [object-auditor] in object-server.conf-sample
Configuration option=Default value Description
log_name=object-auditorLabel used when logging
log_facility=LOG_LOCAL0Syslog log facility
log_level=INFOLogging level
log_address=/dev/logLocation where syslog sends the logs to
files_per_second=20Maximum files audited per second. Should be tuned according to individual system specs. 0 is unlimited.
bytes_per_second=10000000Maximum bytes audited per second. Should be tuned according to individual system specs. 0 is unlimited. mounted to prevent accidentally writing to the root device process simultaneously (it will actually accept(2) N + 1). Setting this to one (1) will only handle one request at a time, without accepting another request concurrently. By increasing the number of workers to a much higher value, one can reduce the impact of slow file system operations in one request from negatively impacting other requests. underlying filesystem does not support it. to setup custom log handlers. bytes you'd like fallocate to reserve, whether there is space for the given file size or not. This is useful for systems that behave badly when they completely run out of space; you can make the services pretend they're out of space early. container server. For most cases, this should be `egg:swift#container`.
log_time=3600Frequency of status logs in seconds.
zero_byte_files_per_second=50Maximum zero byte files audited per second.
recon_cache_path=/var/cache/swiftDirectory where stats for a few items will be stored
object_size_stats=No help text available for this option