Description of ML2 Cisco mechanism driver configuration options
Configuration option = Default value Description
[DEFAULT]
= openstack (StrOpt) Prefix for APIC domain/names/profiles created
[ml2_cisco]
= False (BoolOpt) Enable strict host key checks when connecting to Nexus switches
= None (StrOpt) The physical network managed by the switches.
= False (BoolOpt) Prevent caching ssh connections to Nexus device
= False (BoolOpt) To make Nexus configuration persistent
= True (BoolOpt) Provider VLANs are automatically created as needed on the Nexus switch
= True (BoolOpt) Provider VLANs are automatically trunked as needed on the ports of the Nexus switch
= p- (StrOpt) VLAN Name prefix for provider vlans
= False (BoolOpt) Distribute SVI interfaces over all switches
= 0 (IntOpt) Periodic time to check switch connection. (0=disabled)
= q- (StrOpt) VLAN Name prefix
= False (BoolOpt) Create and delete Nexus switch VXLAN global settings; feature nv overlay, feature vn-segment-vlan-based, interface nve + source-interface loopback
[ml2_cisco_apic]
= 2 (FloatOpt) Interval between agent poll for topology (in sec)
= 30 (FloatOpt) Interval between agent status updates (in sec)
= ${apic_system_id}_app (StrOpt) Name for the app profile used for Openstack
= ${apic_system_id} (StrOpt) Name for the domain created on APIC
= ${apic_system_id}_entity_profile (StrOpt) Name of the entity profile to be created
= ${apic_system_id}_function_profile (StrOpt) Name of the function profile to be created
= (ListOpt) The uplink ports to check for ACI connectivity
= (ListOpt) An ordered list of host names or IP addresses of the APIC controller(s).
= ${apic_system_id}_lacp_profile (StrOpt) Name of the LACP profile to be created
= use_name (StrOpt) Name mapping strategy to use: use_uuid | use_name
= ${apic_system_id}_node_profile (StrOpt) Name of the node profile to be created
= None (StrOpt) Password for the APIC controller
= 0 (IntOpt) Synchronization interval in seconds
= True (BoolOpt) Use SSL to connect to the APIC controller
= None (StrOpt) Username for the APIC controller
= ${apic_system_id}_vlan_ns (StrOpt) Name for the vlan namespace to be used for Openstack
= 2:4093 (StrOpt) Range of VLAN's to be used for Openstack
= (ListOpt) The switch pairs for VPC connectivity
[ml2_cisco_n1kv]
= default-pp (StrOpt) Cisco Nexus1000V default policy profile.
= 4 (IntOpt) Number of threads to use to make HTTP requests.
= 15 (IntOpt) HTTP timeout, in seconds, for connections to the Cisco Nexus1000V VSMs.
= None (ListOpt) Comma Separated IP Addresses of the Cisco Nexus1000V VSMs.
= None (StrOpt) Password for all configured Cisco Nexus1000V VSMs.
= 60 (IntOpt) Cisco Nexus1000V policy profile polling duration in seconds.
= False (BoolOpt) Restrict the visibility of network profiles to the tenants.
= False (BoolOpt) Restrict the visibility of policy profiles to the tenants.
= 300 (IntOpt) Time interval between consecutive neutron-VSM syncs.
= None (StrOpt) Username for all configured Cisco Nexus1000V VSMs.
[ml2_cisco_ucsm]
= 1137:0071, 8086:10c9 (ListOpt) List of comma separated vendor_id:product_id of SR_IOV capable devices supported by this MD. This MD supports both VM-FEX and SR-IOV devices.
= None (ListOpt) List of comma separated Host:Service Profile tuples providing the Service Profile associated with each Host to be supported by this MD.
= None (StrOpt) Cisco UCS Manager IP address. This is a required field to communicate with a Cisco UCS Manager.
= None (StrOpt) Password for UCS Manager. This is a required field to communicate with a Cisco UCS Manager.
= None (StrOpt) Username for UCS Manager. This is a required field to communicate with a Cisco UCS Manager.
[ml2_type_nexus_vxlan]
= (ListOpt) List of multicast groups to be used for global VNIDsin the format - a:b,c,e:f.
= (ListOpt) List of global VNID ranges in the format - a:b, c:d.Multiple ranges can be separated by a comma