<?xml version="1.0" encoding="UTF-8"?>
|
|
<!-- Warning: Do not edit this file. It is automatically
|
|
generated and your changes will be overwritten.
|
|
The tool to do so lives in the tools directory of this
|
|
repository -->
|
|
<para xmlns="http://docbook.org/ns/docbook" version="5.0">
|
|
<table rules="all">
|
|
<caption>Description of configuration options for agent</caption>
|
|
<col width="50%"/>
|
|
<col width="50%"/>
|
|
<thead>
|
|
<tr>
|
|
<th>Configuration option = Default value</th>
|
|
<th>Description</th>
|
|
</tr>
|
|
</thead>
|
|
<tbody>
|
|
<tr>
|
|
<td>agent_down_time = 9</td>
|
|
<td>(IntOpt) Seconds to regard the agent is down; should be at least twice report_interval, to be sure the agent is down for good.</td>
|
|
</tr>
|
|
<tr>
|
|
<td>external_pids = $state_path/external/pids</td>
|
|
<td>(StrOpt) Location to store child pid files</td>
|
|
</tr>
|
|
<tr>
|
|
<td>interface_driver = None</td>
|
|
<td>(StrOpt) The driver used to manage the virtual interface.</td>
|
|
</tr>
|
|
<tr>
|
|
<td>report_interval = 4</td>
|
|
<td>(FloatOpt) Seconds between nodes reporting state to server; should be less than agent_down_time, best if it is half or less than agent_down_time.</td>
|
|
</tr>
|
|
<tr>
|
|
<td>use_namespaces = True</td>
|
|
<td>(BoolOpt) Allow overlapping IP.</td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|