bb680dfdc7
This re-runs the autodoc tool to generate new flagmappings for cinder from the recent trunk. It starts to separate out the 'storage' category into various driver components. Change-Id: Iaa8770001fcb182403ce9f1b756d4732d06bc3f6
72 lines
3.3 KiB
XML
72 lines
3.3 KiB
XML
<?xml version="1.0" encoding="UTF-8"?>
|
|
<!-- Warning: Do not edit this file. It is automatically
|
|
generated and your changes will be overwritten.
|
|
The tool to do so lives in the tools directory of this
|
|
repository -->
|
|
<para xmlns="http://docbook.org/ns/docbook" version="5.0">
|
|
<table rules="all">
|
|
<caption>Description of configuration options for storwize</caption>
|
|
<col width="50%"/>
|
|
<col width="50%"/>
|
|
<thead>
|
|
<tr>
|
|
<td>Configuration option=Default value</td>
|
|
<td>Description</td>
|
|
</tr>
|
|
</thead>
|
|
<tbody>
|
|
<tr>
|
|
<td>storwize_svc_connection_protocol=iSCSI</td>
|
|
<td>(StrOpt) Connection protocol (iSCSI/FC)</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_flashcopy_timeout=120</td>
|
|
<td>(IntOpt) Maximum number of seconds to wait for FlashCopy to be prepared. Maximum value is 600 seconds (10 minutes)</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_iscsi_chap_enabled=True</td>
|
|
<td>(BoolOpt) Configure CHAP authentication for iSCSI connections (Default: Enabled)</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_multihostmap_enabled=True</td>
|
|
<td>(BoolOpt) Allows vdisk to multi host mapping</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_multipath_enabled=False</td>
|
|
<td>(BoolOpt) Connect with multipath (FC only; iSCSI multipath is controlled by Nova)</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_vol_autoexpand=True</td>
|
|
<td>(BoolOpt) Storage system autoexpand parameter for volumes (True/False)</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_vol_compression=False</td>
|
|
<td>(BoolOpt) Storage system compression option for volumes</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_vol_easytier=True</td>
|
|
<td>(BoolOpt) Enable Easy Tier for volumes</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_vol_grainsize=256</td>
|
|
<td>(IntOpt) Storage system grain size parameter for volumes (32/64/128/256)</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_vol_iogrp=0</td>
|
|
<td>(IntOpt) The I/O group in which to allocate volumes</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_volpool_name=volpool</td>
|
|
<td>(StrOpt) Storage system storage pool for volumes</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_vol_rsize=2</td>
|
|
<td>(IntOpt) Storage system space-efficiency parameter for volumes (percentage)</td>
|
|
</tr>
|
|
<tr>
|
|
<td>storwize_svc_vol_warning=0</td>
|
|
<td>(IntOpt) Storage system threshold for volume capacity warnings (percentage)</td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|
</para> |