<section xml:id="emc-vnx-direct-driver"
|
|
xmlns="http://docbook.org/ns/docbook"
|
|
xmlns:xi="http://www.w3.org/2001/XInclude"
|
|
xmlns:xlink="http://www.w3.org/1999/xlink" version="5.0">
|
|
<?dbhtml stop-chunking?>
|
|
<title>EMC VNX direct driver</title>
|
|
<para>Use the EMC VNX direct driver to create, attach, detach, and
|
|
delete volumes, create and delete snapshots, and so on. This driver
|
|
is based on the Cinder-defined <literal>ISCSIDriver</literal> driver.
|
|
</para>
|
|
<para>To complete volume operations, the driver uses the NaviSec
|
|
command-line interface (CLI) to communicate with back-end EMC VNX
|
|
storage.
|
|
</para>
|
|
<section xml:id="emc-vnx-direct-reqs">
|
|
<title>System requirements</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Flare version 5.32 or later.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>You must activate VNX Snapshot and Thin Provisioning license
|
|
for the array. Ensure that all the iSCSI ports from the
|
|
VNX are accessible through OpenStack hosts.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Navisphere CLI v7.32 or later.</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>EMC storage VNX Series are supported.</para>
|
|
</section>
|
|
<section xml:id="emc-vnx-direct-supported-ops">
|
|
<title>Supported operations</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Create volume</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Delete volume</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Attach volume</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Detach volume</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Create snapshot</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Delete snapshot</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Create volume from snapshot</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Create cloned volume</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Copy image to volume</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Copy volume to image</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Extend volume</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
<section xml:id="emc-vnx-direct-prep">
|
|
<title>Set up the VNX direct driver</title>
|
|
<para>Complete these high-level tasks to set up the VNX direct driver:
|
|
</para>
|
|
<orderedlist>
|
|
<listitem>
|
|
<para>Install NaviSecCLI. You must install the NaviSecCLI
|
|
tool on the controller node and all the Cinder nodes in
|
|
an OpenStack deployment. See <xref
|
|
linkend="install-naviseccli"/>.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Register with VNX. See <xref
|
|
linkend="register-vnx-direct-iscsi"/>
|
|
</para>
|
|
</listitem>
|
|
</orderedlist>
|
|
<section xml:id="install-naviseccli">
|
|
<title>Install NaviSecCLI</title>
|
|
<para>On Ubuntu x64, download the NaviSecCLI deb package from <link xlink:href="https://github.com/emc-openstack/naviseccli">EMC's OpenStack GitHub</link> web site.
|
|
</para>
|
|
<para>For all the other variants of Linux, download the NaviSecCLI rpm package from EMC's support web site for <link xlink:href="https://support.emc.com/downloads/36656_VNX2-Series">VNX2 series</link> or <link xlink:href="https://support.emc.com/downloads/12781_VNX1-Series">VNX1 series</link>. Login is required.
|
|
</para>
|
|
</section>
|
|
<section xml:id="register-vnx-direct-iscsi">
|
|
<title>Register with VNX</title>
|
|
<para>To export a VNX volume to a compute node or a volume node,
|
|
you must register the node with VNX.</para>
|
|
<procedure>
|
|
<title>To register the node</title>
|
|
<step><para>On the compute node or volume node <literal>1.1.1.1</literal>, do
|
|
the following (assume <literal>10.10.61.35</literal>
|
|
is the iSCSI target):</para>
|
|
<screen><prompt>#</prompt> <userinput>/etc/init.d/open-iscsi start</userinput>
|
|
<prompt>#</prompt> <userinput>iscsiadm -m discovery -t st -p 10.10.61.35</userinput>
|
|
<prompt>#</prompt> <userinput>cd /etc/iscsi</userinput>
|
|
<prompt>#</prompt> <userinput>more initiatorname.iscsi</userinput>
|
|
<prompt>#</prompt> <userinput>iscsiadm -m node</userinput></screen></step>
|
|
<step><para>Log in to VNX from the node using the target
|
|
corresponding to the SPA port:</para>
|
|
<screen><prompt>#</prompt> <userinput>iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.a0 -p 10.10.61.35 -l</userinput></screen>
|
|
<para>Where
|
|
<literal>iqn.1992-04.com.emc:cx.apm01234567890.a0</literal>
|
|
is the initiator name of the node. Login to
|
|
Unisphere, go to
|
|
<literal>VNX00000</literal>->Hosts->Initiators,
|
|
Refresh and wait until initiator
|
|
<literal>iqn.1992-04.com.emc:cx.apm01234567890.a0</literal>
|
|
with SP Port <literal>A-8v0</literal> appears.</para></step>
|
|
<step><para>Click <guibutton>Register</guibutton>,
|
|
select <guilabel>CLARiiON/VNX</guilabel>,
|
|
and enter the host name <literal>myhost1</literal> and
|
|
IP address <literal>myhost1</literal>. Click <guibutton>Register</guibutton>.
|
|
Now host <literal>1.1.1.1</literal> also appears under
|
|
Hosts->Host List.</para></step>
|
|
<step><para>Log out of VNX on the node:</para>
|
|
<screen><prompt>#</prompt> <userinput>iscsiadm -m node -u</userinput></screen></step>
|
|
<step>
|
|
<para>Log in to VNX from the node using the target
|
|
corresponding to the SPB port:</para>
|
|
<screen><prompt>#</prompt> <userinput>iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.b8 -p 10.10.10.11 -l</userinput></screen>
|
|
</step>
|
|
<step> <para>In Unisphere register the initiator with the SPB
|
|
port.</para></step>
|
|
<step><para>Log out:</para>
|
|
<screen><prompt>#</prompt> <userinput>iscsiadm -m node -u</userinput></screen></step>
|
|
</procedure>
|
|
</section>
|
|
<section xml:id="emc-vnx-direct-config-file">
|
|
<title><filename>cinder.conf</filename> configuration
|
|
file</title>
|
|
<para>Make the following changes in
|
|
<filename>/etc/cinder/cinder.conf</filename>.</para>
|
|
<para>For the VNX iSCSI driver, add the following entries, where
|
|
<literal>10.10.61.35</literal> is the IP address
|
|
of the VNX iSCSI target, <literal>10.10.72.41</literal>
|
|
is the IP address of the VNX array (SPA or SPB),
|
|
<systemitem>default_timeout</systemitem> is the default
|
|
time out for CLI operations in minutes, and
|
|
<systemitem>max_luns_per_storage_group</systemitem> is
|
|
the default max number of LUNs in a storage group:</para>
|
|
<programlisting language="ini">
|
|
iscsi_ip_address = 10.10.61.35
|
|
san_ip = 10.10.72.41
|
|
san_login = global_username
|
|
san_password = password
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
storage_vnx_pool_name = poolname
|
|
default_timeout = 10
|
|
max_luns_per_storage_group=256
|
|
volume_driver=cinder.volume.drivers.emc.emc_cli_iscsi.EMCCLIISCSIDriver
|
|
</programlisting>
|
|
<note>
|
|
<para>To find out <literal>max_luns_per_storage_group
|
|
</literal> for each VNX model, refer to the
|
|
<link xlink:href="https://support.emc.com/search/?text=White%20Paper%20Introduction%20to%20the%20VNX%20Series">EMC's support</link> web site (login is required).
|
|
</para>
|
|
</note>
|
|
<para>Restart the <systemitem class="service"
|
|
>cinder-volume</systemitem> service.</para>
|
|
</section>
|
|
<section xml:id="emc-vnx-direct-volume-type">
|
|
<title>Volume type support</title>
|
|
<para>Volume type support allows user to choose thick/thin
|
|
provisioning capabilities.</para>
|
|
<para>Here is an example of how to setup volume type.
|
|
First create volume types. Then define extra specs for
|
|
each volume type.</para>
|
|
<procedure>
|
|
<title>To set up volume types</title>
|
|
<step>
|
|
<para>Setup volume types:</para>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "TypeA"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-create "TypeB"</userinput></screen>
|
|
</step>
|
|
<step>
|
|
<para>Setup volume type extra specs:</para>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-key "TypeA" set storagetype:provisioning=thick</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "TypeB" set storagetype:provisioning=thin</userinput></screen>
|
|
</step>
|
|
</procedure>
|
|
<para>The previous example creates two volume types:
|
|
<literal>TypeA</literal> and <literal>TypeB</literal>.
|
|
For <literal>TypeA</literal>, <literal>storagetype:provisioning
|
|
</literal> is set to <literal>thick</literal>. Similarly
|
|
for <literal>TypeB</literal>, <literal>storagetype:provisioning
|
|
</literal> is set to <literal>thin</literal>. If <literal>
|
|
storagetype:provisioning</literal> is not specified, it will be
|
|
default to <literal>thick</literal>.</para>
|
|
</section>
|
|
</section>
|
|
</section>
|