<section xml:id="netapp-volume-driver"
|
|
xmlns="http://docbook.org/ns/docbook"
|
|
xmlns:xi="http://www.w3.org/2001/XInclude"
|
|
xmlns:xlink="http://www.w3.org/1999/xlink" version="5.0">
|
|
<title>NetApp unified driver</title>
|
|
<para>The NetApp unified driver is a block storage driver that
|
|
supports multiple storage families and protocols. A storage
|
|
family corresponds to storage systems built on different
|
|
NetApp technologies such as clustered Data ONTAP, Data ONTAP
|
|
operating in 7-Mode, and E-Series. The storage protocol refers
|
|
to the protocol used to initiate data storage and access
|
|
operations on those storage systems like iSCSI and NFS. The
|
|
NetApp unified driver can be configured to provision and manage
|
|
OpenStack volumes on a given storage family using a specified
|
|
storage protocol. The OpenStack volumes can then be used for
|
|
accessing and storing data using the storage protocol on the
|
|
storage family system. The NetApp unified driver is an
|
|
extensible interface that can support new storage families and
|
|
protocols.</para>
|
|
<section xml:id="ontap-cluster-family">
|
|
<title>NetApp clustered Data ONTAP storage family</title>
|
|
<para>The NetApp clustered Data ONTAP storage family
|
|
represents a configuration group which provides OpenStack
|
|
compute instances access to clustered Data ONTAP storage
|
|
systems. At present it can be configured in OpenStack Block Storage to work
|
|
with iSCSI and NFS storage protocols.</para>
|
|
<section xml:id="ontap-cluster-iscsi">
|
|
<title>NetApp iSCSI configuration for clustered Data
|
|
ONTAP</title>
|
|
<para>The NetApp iSCSI configuration for clustered Data
|
|
ONTAP is an interface from OpenStack to clustered Data
|
|
ONTAP storage systems for provisioning and managing
|
|
the SAN block storage entity; that is, a NetApp LUN
|
|
which can be accessed using the iSCSI protocol.</para>
|
|
<para>The iSCSI configuration for clustered Data ONTAP is
|
|
a direct interface from OpenStack Block Storage to the clustered Data
|
|
ONTAP instance and as such does not require additional
|
|
management software to achieve the desired
|
|
functionality. It uses NetApp APIs to interact with
|
|
the clustered Data ONTAP instance.</para>
|
|
<simplesect>
|
|
<title>Configuration options for clustered Data ONTAP
|
|
family with iSCSI protocol</title>
|
|
<para>Configure the volume driver, storage family and
|
|
storage protocol to the NetApp unified driver,
|
|
clustered Data ONTAP, and iSCSI respectively by
|
|
setting the <option>volume_driver</option>,
|
|
<option>netapp_storage_family</option> and
|
|
<option>netapp_storage_protocol</option>
|
|
options in <filename>cinder.conf</filename> as
|
|
follows:</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_cluster
|
|
netapp_storage_protocol = iscsi
|
|
netapp_vserver = <replaceable>openstack-vserver</replaceable>
|
|
netapp_server_hostname = <replaceable>myhostname</replaceable>
|
|
netapp_server_port = <replaceable>port</replaceable>
|
|
netapp_login = <replaceable>username</replaceable>
|
|
netapp_password = <replaceable>password</replaceable></programlisting>
|
|
<note>
|
|
<para>
|
|
To use the iSCSI protocol, you must override the
|
|
default value of
|
|
<option>netapp_storage_protocol</option> with
|
|
<literal>iscsi</literal>.
|
|
</para>
|
|
</note>
|
|
<xi:include
|
|
href="../../../common/tables/cinder-netapp_cdot_iscsi.xml"/>
|
|
<note>
|
|
<para>If you specify an account in the
|
|
<option>netapp_login</option> that only
|
|
has virtual storage server (Vserver)
|
|
administration privileges (rather than
|
|
cluster-wide administration privileges), some
|
|
advanced features of the NetApp unified driver
|
|
will not work and you may see warnings in the
|
|
OpenStack Block Storage logs.</para>
|
|
</note>
|
|
<tip>
|
|
<para>For more information on these options and
|
|
other deployment and operational scenarios,
|
|
visit the <link
|
|
xlink:href="https://communities.netapp.com/groups/openstack"
|
|
> OpenStack NetApp
|
|
community</link>.</para>
|
|
</tip>
|
|
</simplesect>
|
|
</section>
|
|
<section xml:id="ontap-cluster-nfs">
|
|
<title>NetApp NFS configuration for clustered Data
|
|
ONTAP</title>
|
|
<para>The NetApp NFS configuration for clustered Data
|
|
ONTAP is an interface from OpenStack to a clustered
|
|
Data ONTAP system for provisioning and managing
|
|
OpenStack volumes on NFS exports provided by the
|
|
clustered Data ONTAP system that are accessed using
|
|
the NFS protocol.</para>
|
|
<para>The NFS configuration for clustered Data ONTAP is a
|
|
direct interface from OpenStack Block Storage to the clustered Data
|
|
ONTAP instance and as such does not require any
|
|
additional management software to achieve the desired
|
|
functionality. It uses NetApp APIs to interact with
|
|
the clustered Data ONTAP instance.</para>
|
|
<simplesect>
|
|
<title>Configuration options for the clustered Data
|
|
ONTAP family with NFS protocol</title>
|
|
<para>Configure the volume driver, storage family, and
|
|
storage protocol to NetApp unified driver,
|
|
clustered Data ONTAP, and NFS respectively by
|
|
setting the <option>volume_driver</option>,
|
|
<option>netapp_storage_family</option> and
|
|
<option>netapp_storage_protocol</option>
|
|
options in <filename>cinder.conf</filename> as
|
|
follows:</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_cluster
|
|
netapp_storage_protocol = nfs
|
|
netapp_vserver = <replaceable>openstack-vserver</replaceable>
|
|
netapp_server_hostname = <replaceable>myhostname</replaceable>
|
|
netapp_server_port = <replaceable>port</replaceable>
|
|
netapp_login = <replaceable>username</replaceable>
|
|
netapp_password = <replaceable>password</replaceable>
|
|
nfs_shares_config = <replaceable>/etc/cinder/nfs_shares</replaceable></programlisting>
|
|
<xi:include
|
|
href="../../../common/tables/cinder-netapp_cdot_nfs.xml"/>
|
|
<note>
|
|
<para>Additional NetApp NFS configuration options are
|
|
shared with the generic NFS driver. These options
|
|
can be found here:
|
|
<xref linkend="config_table_cinder_storage_nfs"/>.
|
|
</para>
|
|
</note>
|
|
<note>
|
|
<para>If you specify an account in the
|
|
<option>netapp_login</option> that only
|
|
has virtual storage server (Vserver)
|
|
administration privileges (rather than
|
|
cluster-wide administration privileges), some
|
|
advanced features of the NetApp unified driver
|
|
will not work and you may see warnings in the
|
|
OpenStack Block Storage logs.</para>
|
|
</note>
|
|
</simplesect>
|
|
<simplesect>
|
|
<title>NetApp NFS Copy Offload client</title>
|
|
<para>A feature was added in the Icehouse release of the NetApp unified
|
|
driver that enables Image Service images to be efficiently copied to a
|
|
destination Block Storage volume. When the Block Storage and Image Service are
|
|
configured to use the NetApp NFS Copy Offload client, a controller-side copy
|
|
will be attempted before reverting to downloading the image from the
|
|
Image Service. This improves image provisioning times while reducing the
|
|
consumption of bandwidth and CPU cycles on the host(s) running the Image
|
|
and Block Storage services. This is due to the copy operation being performed
|
|
completely within the storage cluster.</para>
|
|
<para>The NetApp NFS Copy Offload client can be used in either of the following
|
|
scenarios:</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>The Image Service is configured to store images in an NFS share that
|
|
is exported from a NetApp FlexVol volume <emphasis>and</emphasis>
|
|
the destination for the new Block Storage volume will be on an NFS share
|
|
exported from a different FlexVol volume than the one used by
|
|
the Image Service. Both FlexVols must be located within the same cluster.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>The source image from the Image Service has already been cached in an NFS
|
|
image cache within a Block Storage backend. The cached image resides on a
|
|
different FlexVol volume than the destination for the new Block Storage
|
|
volume. Both FlexVols must be located within the same cluster.</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>To use this feature, you must configure the
|
|
Image Service, as follows:</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Set the <option>default_store</option>
|
|
configuration option to
|
|
<literal>file</literal>.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Set the <option>filesystem_store_datadir</option>
|
|
configuration option to the
|
|
path to the Image Service NFS export.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Set the <option>show_image_direct_url</option>
|
|
configuration option to
|
|
<literal>True</literal>.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Set the <option>show_multiple_locations</option>
|
|
configuration option to
|
|
<literal>True</literal>.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Set the <option>filesystem_store_metadata_file</option>
|
|
configuration option to a
|
|
metadata file. The metadata file should
|
|
contain a JSON object that contains the
|
|
correct information about the NFS export
|
|
used by the Image Service, similar
|
|
to:</para>
|
|
<programlisting language="ini">{
|
|
"share_location": "<replaceable>nfs://192.168.0.1/myGlanceExport</replaceable>",
|
|
"mount_point": "<replaceable>/var/lib/glance/images</replaceable>",
|
|
"type": "nfs"
|
|
}</programlisting>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>To use this feature, you must configure the
|
|
Block Storage service, as follows:</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Set the <option>netapp_copyoffload_tool_path</option>
|
|
configuration option to
|
|
the path to the NetApp Copy Offload binary.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Set the <option>glance_api_version</option>
|
|
configuration option to
|
|
<literal>2</literal>.</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<important>
|
|
<para>This feature requires that:</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>The storage system must have Data
|
|
ONTAP v8.2 or greater installed.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>The vStorage feature must be enabled
|
|
on each storage virtual machine (SVM, also
|
|
known as a Vserver) that is permitted to
|
|
interact with the copy offload
|
|
client.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>To configure the copy offload workflow,
|
|
enable NFS v4.0 or greater
|
|
and export it from the SVM.</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</important>
|
|
<tip>
|
|
<para>To download the NetApp copy offload binary to be utilized
|
|
in conjunction with the <option>netapp_copyoffload_tool_path</option>
|
|
configuration option, please visit the Utility Toolchest page at
|
|
the <link xlink:href="http://mysupport.netapp.com/NOW/download/tools/ntap_openstack_nfs/">
|
|
NetApp Support portal</link> (login is required).</para>
|
|
</tip>
|
|
<tip>
|
|
<para>For more information on these options and other deployment
|
|
and operational scenarios, visit the <link
|
|
xlink:href="https://communities.netapp.com/groups/openstack">
|
|
OpenStack NetApp community</link>.</para>
|
|
</tip>
|
|
</simplesect>
|
|
</section>
|
|
<section xml:id="ontap-cluster-extraspecs">
|
|
<title>NetApp-supported extra specs for clustered Data
|
|
ONTAP</title>
|
|
<para>Extra specs enable vendors to specify extra filter
|
|
criteria that the Block Storage scheduler uses when it
|
|
determines which volume node should fulfill a volume
|
|
provisioning request. When you use the NetApp unified
|
|
driver with a clustered Data ONTAP storage system, you
|
|
can leverage extra specs with OpenStack Block Storage volume types to
|
|
ensure that OpenStack Block Storage volumes are created on storage back
|
|
ends that have certain properties. For example, when
|
|
you configure QoS, mirroring, or compression for a
|
|
storage back end.</para>
|
|
<para>Extra specs are associated with OpenStack Block Storage volume types,
|
|
so that when users request volumes of a particular
|
|
volume type, the volumes are created on storage back
|
|
ends that meet the list of requirements. For example,
|
|
the back ends have the available space or extra specs.
|
|
You can use the specs in the following table when you
|
|
define OpenStack Block Storage volume types by using the
|
|
<command>cinder type-key</command> command.</para>
|
|
<xi:include
|
|
href="../../../common/tables/cinder-netapp_cdot_extraspecs.xml"/>
|
|
<note>
|
|
<para>It is recommended to only set the value of extra
|
|
specs to <literal>True</literal> when combining
|
|
multiple specs to enforce a certain logic set. If
|
|
you desire to remove volumes with a certain
|
|
feature enabled from consideration from the OpenStack Block Storage
|
|
volume scheduler, be sure to use the negated spec
|
|
name with a value of <literal>True</literal>
|
|
rather than setting the positive spec to a value
|
|
of <literal>False</literal>.</para>
|
|
</note>
|
|
</section>
|
|
</section>
|
|
<section xml:id="ontap-7mode-family">
|
|
<title>NetApp Data ONTAP operating in 7-Mode storage
|
|
family</title>
|
|
<para>The NetApp Data ONTAP operating in 7-Mode storage family
|
|
represents a configuration group which provides OpenStack
|
|
compute instances access to 7-Mode storage systems. At
|
|
present it can be configured in OpenStack Block Storage to work with iSCSI
|
|
and NFS storage protocols.</para>
|
|
<section xml:id="ontap-7mode-iscsi">
|
|
<title>NetApp iSCSI configuration for Data ONTAP operating
|
|
in 7-Mode</title>
|
|
<para>The NetApp iSCSI configuration for Data ONTAP
|
|
operating in 7-Mode is an interface from OpenStack to
|
|
Data ONTAP operating in 7-Mode storage systems for
|
|
provisioning and managing the SAN block storage
|
|
entity, that is, a LUN which can be accessed using
|
|
iSCSI protocol.</para>
|
|
<para>The iSCSI configuration for Data ONTAP operating in
|
|
7-Mode is a direct interface from OpenStack to Data
|
|
ONTAP operating in 7-Mode storage system and it does
|
|
not require additional management software to achieve
|
|
the desired functionality. It uses NetApp ONTAPI to
|
|
interact with the Data ONTAP operating in 7-Mode
|
|
storage system.</para>
|
|
<simplesect>
|
|
<title>Configuration options for the Data ONTAP
|
|
operating in 7-Mode storage family with iSCSI
|
|
protocol</title>
|
|
<para>Configure the volume driver, storage family and
|
|
storage protocol to the NetApp unified driver,
|
|
Data ONTAP operating in 7-Mode, and iSCSI
|
|
respectively by setting the
|
|
<option>volume_driver</option>,
|
|
<option>netapp_storage_family</option> and
|
|
<option>netapp_storage_protocol</option>
|
|
options in <filename>cinder.conf</filename> as
|
|
follows:</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_7mode
|
|
netapp_storage_protocol = iscsi
|
|
netapp_server_hostname = <replaceable>myhostname</replaceable>
|
|
netapp_server_port = <replaceable>80</replaceable>
|
|
netapp_login = <replaceable>username</replaceable>
|
|
netapp_password = <replaceable>password</replaceable></programlisting>
|
|
<note>
|
|
<para>
|
|
To use the iSCSI protocol, you must override the
|
|
default value of
|
|
<option>netapp_storage_protocol</option> with
|
|
<literal>iscsi</literal>.
|
|
</para>
|
|
</note>
|
|
<xi:include
|
|
href="../../../common/tables/cinder-netapp_7mode_iscsi.xml"/>
|
|
<tip>
|
|
<para>For more information on these options and
|
|
other deployment and operational scenarios,
|
|
visit the <link
|
|
xlink:href="https://communities.netapp.com/groups/openstack"
|
|
>OpenStack NetApp community</link>.</para>
|
|
</tip>
|
|
</simplesect>
|
|
</section>
|
|
<section xml:id="ontap-7mode-nfs">
|
|
<title>NetApp NFS configuration for Data ONTAP operating
|
|
in 7-Mode</title>
|
|
<para>The NetApp NFS configuration for Data ONTAP
|
|
operating in 7-Mode is an interface from OpenStack to
|
|
Data ONTAP operating in 7-Mode storage system for
|
|
provisioning and managing OpenStack volumes on NFS
|
|
exports provided by the Data ONTAP operating in 7-Mode
|
|
storage system which can then be accessed using NFS
|
|
protocol.</para>
|
|
<para>The NFS configuration for Data ONTAP operating in
|
|
7-Mode is a direct interface from OpenStack Block Storage to the Data
|
|
ONTAP operating in 7-Mode instance and as such does
|
|
not require any additional management software to
|
|
achieve the desired functionality. It uses NetApp
|
|
ONTAPI to interact with the Data ONTAP operating in
|
|
7-Mode storage system.</para>
|
|
<simplesect>
|
|
<title>Configuration options for the Data ONTAP
|
|
operating in 7-Mode family with NFS
|
|
protocol</title>
|
|
<para>Configure the volume driver, storage family, and
|
|
storage protocol to the NetApp unified driver,
|
|
Data ONTAP operating in 7-Mode, and NFS
|
|
respectively by setting the
|
|
<option>volume_driver</option>,
|
|
<option>netapp_storage_family</option> and
|
|
<option>netapp_storage_protocol</option>
|
|
options in <filename>cinder.conf</filename> as
|
|
follows:</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_7mode
|
|
netapp_storage_protocol = nfs
|
|
netapp_server_hostname = <replaceable>myhostname</replaceable>
|
|
netapp_server_port = <replaceable>80</replaceable>
|
|
netapp_login = <replaceable>username</replaceable>
|
|
netapp_password = <replaceable>password</replaceable>
|
|
nfs_shares_config = <replaceable>/etc/cinder/nfs_shares</replaceable></programlisting>
|
|
<xi:include
|
|
href="../../../common/tables/cinder-netapp_7mode_nfs.xml"/>
|
|
<note>
|
|
<para>Additional NetApp NFS configuration options
|
|
are shared with the generic NFS driver. For a
|
|
description of these, see
|
|
<xref linkend="config_table_cinder_storage_nfs"/>.
|
|
</para>
|
|
</note>
|
|
<tip>
|
|
<para>For more information on these options and
|
|
other deployment and operational scenarios,
|
|
visit the <link
|
|
xlink:href="https://communities.netapp.com/groups/openstack"
|
|
>OpenStack NetApp community</link>.</para>
|
|
</tip>
|
|
</simplesect>
|
|
</section>
|
|
</section>
|
|
<section xml:id="eseries-family">
|
|
<title>NetApp E-Series storage family</title>
|
|
<para>The NetApp E-Series storage family represents a
|
|
configuration group which provides OpenStack
|
|
compute instances access to E-Series storage systems.
|
|
At present it can be configured in OpenStack Block Storage to work
|
|
with the iSCSI storage protocol.</para>
|
|
<section xml:id="eseries-iscsi">
|
|
<title>NetApp iSCSI configuration for E-Series</title>
|
|
<para>The NetApp iSCSI configuration for E-Series
|
|
is an interface from OpenStack to E-Series storage
|
|
systems for provisioning and managing the SAN block
|
|
storage entity; that is, a NetApp LUN which can be
|
|
accessed using the iSCSI protocol.</para>
|
|
<para>The iSCSI configuration for E-Series is an interface
|
|
from OpenStack Block Storage to the E-Series proxy instance and as such
|
|
requires the deployment of the proxy instance in order to
|
|
achieve the desired functionality. The driver uses REST
|
|
APIs to interact with the E-Series proxy instance, which in
|
|
turn interacts directly with the E-Series controllers.</para>
|
|
<simplesect>
|
|
<title>Configuration options for E-Series storage
|
|
family with iSCSI protocol</title>
|
|
<para>Configure the volume driver, storage family, and
|
|
storage protocol to the NetApp unified driver,
|
|
E-Series, and iSCSI respectively by setting the
|
|
<option>volume_driver</option>,
|
|
<option>netapp_storage_family</option> and
|
|
<option>netapp_storage_protocol</option>
|
|
options in <filename>cinder.conf</filename> as
|
|
follows:</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = eseries
|
|
netapp_storage_protocol = iscsi
|
|
netapp_server_hostname = <replaceable>myhostname</replaceable>
|
|
netapp_server_port = <replaceable>80</replaceable>
|
|
netapp_login = <replaceable>username</replaceable>
|
|
netapp_password = <replaceable>password</replaceable>
|
|
netapp_controller_ips = <replaceable>1.2.3.4,5.6.7.8</replaceable>
|
|
netapp_sa_password = <replaceable>arrayPassword</replaceable>
|
|
netapp_storage_pools = <replaceable>pool1,pool2</replaceable></programlisting>
|
|
<note>
|
|
<para>
|
|
To use the E-Series driver, you must override
|
|
the default value of
|
|
<option>netapp_storage_family</option> with
|
|
<literal>eseries</literal>.
|
|
</para>
|
|
</note>
|
|
<note>
|
|
<para>
|
|
To use the iSCSI protocol, you must override the
|
|
default value of
|
|
<option>netapp_storage_protocol</option> with
|
|
<literal>iscsi</literal>.
|
|
</para>
|
|
</note>
|
|
<xi:include
|
|
href="../../../common/tables/cinder-netapp_eseries_iscsi.xml"/>
|
|
<tip>
|
|
<para>For more information on these options and
|
|
other deployment and operational scenarios,
|
|
visit the <link
|
|
xlink:href="https://communities.netapp.com/groups/openstack"
|
|
> OpenStack NetApp
|
|
community.</link></para>
|
|
</tip>
|
|
</simplesect>
|
|
</section>
|
|
</section>
|
|
<section xml:id="ontap-unified-upgrade-deprecated">
|
|
<title>Upgrading prior NetApp drivers to the NetApp unified
|
|
driver</title>
|
|
<para>NetApp introduced a new unified block storage driver in
|
|
Havana for configuring different storage families and
|
|
storage protocols. This requires defining upgrade path for
|
|
NetApp drivers which existed in releases prior to Havana.
|
|
This section covers the upgrade configuration for NetApp
|
|
drivers to the new unified configuration and a list of
|
|
deprecated NetApp drivers.</para>
|
|
<section xml:id="ontap-unified-upgrade">
|
|
<title>Upgraded NetApp drivers</title>
|
|
<para>This section describes how to update OpenStack Block Storage
|
|
configuration from a pre-Havana release to the
|
|
unified driver format.</para>
|
|
<simplesect>
|
|
<title>Driver upgrade configuration</title>
|
|
<orderedlist>
|
|
<listitem>
|
|
<para>NetApp iSCSI direct driver for Clustered
|
|
Data ONTAP in Grizzly (or earlier).</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppDirectCmodeISCSIDriver</programlisting>
|
|
<para>NetApp unified driver
|
|
configuration.</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_cluster
|
|
netapp_storage_protocol = iscsi</programlisting>
|
|
</listitem>
|
|
<listitem>
|
|
<para>NetApp NFS direct driver for Clustered
|
|
Data ONTAP in Grizzly (or earlier).</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.nfs.NetAppDirectCmodeNfsDriver</programlisting>
|
|
<para>NetApp unified driver
|
|
configuration.</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_cluster
|
|
netapp_storage_protocol = nfs</programlisting>
|
|
</listitem>
|
|
<listitem>
|
|
<para>NetApp iSCSI direct driver for Data
|
|
ONTAP operating in 7-Mode storage
|
|
controller in Grizzly (or earlier)</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppDirect7modeISCSIDriver</programlisting>
|
|
<para>NetApp unified driver
|
|
configuration</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_7mode
|
|
netapp_storage_protocol = iscsi</programlisting>
|
|
</listitem>
|
|
<listitem>
|
|
<para>NetApp NFS direct driver for Data ONTAP
|
|
operating in 7-Mode storage controller in
|
|
Grizzly (or earlier)</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.nfs.NetAppDirect7modeNfsDriver</programlisting>
|
|
<para>NetApp unified driver
|
|
configuration</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
|
netapp_storage_family = ontap_7mode
|
|
netapp_storage_protocol = nfs</programlisting>
|
|
</listitem>
|
|
</orderedlist>
|
|
|
|
</simplesect>
|
|
</section>
|
|
<section xml:id="ontap-driver-deprecate">
|
|
<title>Deprecated NetApp drivers</title>
|
|
<para>This section lists the NetApp drivers in earlier
|
|
releases that are deprecated in Havana.</para>
|
|
<orderedlist>
|
|
<listitem>
|
|
<para>NetApp iSCSI driver for clustered Data
|
|
ONTAP.</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppCmodeISCSIDriver</programlisting>
|
|
</listitem>
|
|
<listitem>
|
|
<para>NetApp NFS driver for clustered Data
|
|
ONTAP.</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.nfs.NetAppCmodeNfsDriver</programlisting>
|
|
</listitem>
|
|
<listitem>
|
|
<para>NetApp iSCSI driver for Data ONTAP operating
|
|
in 7-Mode storage controller.</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppISCSIDriver</programlisting>
|
|
</listitem>
|
|
<listitem>
|
|
<para>NetApp NFS driver for Data ONTAP operating
|
|
in 7-Mode storage controller.</para>
|
|
<programlisting language="ini">volume_driver = cinder.volume.drivers.netapp.nfs.NetAppNFSDriver</programlisting>
|
|
</listitem>
|
|
</orderedlist>
|
|
<note>
|
|
<para>See the <link
|
|
xlink:href="https://communities.netapp.com/groups/openstack"
|
|
>OpenStack NetApp community</link> for support
|
|
information on deprecated NetApp drivers in the
|
|
Havana release.</para>
|
|
</note>
|
|
</section>
|
|
</section>
|
|
</section>
|