openstack-manuals/doc/common/tables/cinder-netapp_7mode_iscsi.xml
Bob Callaway d2a3713fe7 Update help text for netapp_server_port option
https://review.openstack.org/#/c/128700/ merged upstream in Kilo last
night; this change is a result of running the autohelp-wrapper from
openstack-doc-tools on the master branch of cinder.

Change-Id: I1eb4ebb7e819e62d0d956f853f0f77265d07016e
2014-10-16 20:31:01 -04:00

63 lines
3.2 KiB
XML

<?xml version='1.0' encoding='UTF-8'?>
<para xmlns="http://docbook.org/ns/docbook" version="5.0">
<!-- Warning: Do not edit this file. It is automatically
generated and your changes will be overwritten.
The tool to do so lives in openstack-doc-tools repository. -->
<table rules="all" xml:id="config_table_cinder_netapp_7mode_iscsi">
<caption>Description of NetApp 7-Mode iSCSI driver configuration options</caption>
<col width="50%"/>
<col width="50%"/>
<thead>
<tr>
<th>Configuration option = Default value</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<th colspan="2">[DEFAULT]</th>
</tr>
<tr>
<td>netapp_login = None</td>
<td>(StrOpt) Administrative user account name used to access the storage system or proxy server.</td>
</tr>
<tr>
<td>netapp_password = None</td>
<td>(StrOpt) Password for the administrative user account specified in the netapp_login option.</td>
</tr>
<tr>
<td>netapp_server_hostname = None</td>
<td>(StrOpt) The hostname (or IP address) for the storage system or proxy server.</td>
</tr>
<tr>
<td>netapp_server_port = None</td>
<td>(IntOpt) The TCP port to use for communication with the storage system or proxy server. If not specified, Data ONTAP drivers will use 80 for HTTP and 443 for HTTPS; E-Series will use 8080 for HTTP and 8443 for HTTPS.</td>
</tr>
<tr>
<td>netapp_size_multiplier = 1.2</td>
<td>(FloatOpt) The quantity to be multiplied by the requested volume size to ensure enough space is available on the virtual storage server (Vserver) to fulfill the volume creation request.</td>
</tr>
<tr>
<td>netapp_storage_family = ontap_cluster</td>
<td>(StrOpt) The storage family type used on the storage system; valid values are ontap_7mode for using Data ONTAP operating in 7-Mode, ontap_cluster for using clustered Data ONTAP, or eseries for using E-Series.</td>
</tr>
<tr>
<td>netapp_storage_protocol = None</td>
<td>(StrOpt) The storage protocol to be used on the data path with the storage system; valid values are iscsi or nfs.</td>
</tr>
<tr>
<td>netapp_transport_type = http</td>
<td>(StrOpt) The transport protocol used when communicating with the storage system or proxy server. Valid values are http or https.</td>
</tr>
<tr>
<td>netapp_vfiler = None</td>
<td>(StrOpt) The vFiler unit on which provisioning of block storage volumes will be done. This option is only used by the driver when connecting to an instance with a storage family of Data ONTAP operating in 7-Mode and the storage protocol selected is iSCSI. Only use this option when utilizing the MultiStore feature on the NetApp storage system.</td>
</tr>
<tr>
<td>netapp_volume_list = None</td>
<td>(StrOpt) This option is only utilized when the storage protocol is configured to use iSCSI. This option is used to restrict provisioning to the specified controller volumes. Specify the value of this option to be a comma separated list of NetApp controller volume names to be used for provisioning.</td>
</tr>
</tbody>
</table>