<section xml:id="hp-3par-driver" xmlns="http://docbook.org/ns/docbook"
xmlns:xi="http://www.w3.org/2001/XInclude"
xmlns:xlink="http://www.w3.org/1999/xlink" version="5.0">
<title>HP 3PAR Fibre Channel and iSCSI drivers</title>
<para>The <filename>HP3PARFCDriver</filename> and
<filename>HP3PARISCSIDriver</filename> drivers, which are
based on the Block Storage Service (Cinder) plug-in
architecture, run volume operations by communicating with the
HP 3PAR storage system over HTTP, HTTPS, and SSH connections.
The HTTP and HTTPS communications use
<package>hp3parclient</package>, which is part of the
Python standard library.</para>
<para>For information about how to manage HP 3PAR storage systems,
see the HP 3PAR user documentation.</para>
<section xml:id="hp-3par-sys-reqs">
<title>System requirements</title>
<para>To use the HP 3PAR drivers, install the following
software and components on the HP 3PAR storage
system:</para>
<itemizedlist>
<listitem>
<para>HP 3PAR Operating System software version 3.1.2
(MU3) or higher</para>
</listitem>
<listitem>
<para>HP 3PAR Web Services API Server must be enabled
and running</para>
</listitem>
<listitem>
<para>One Common Provisioning Group (CPG)</para>
</listitem>
<listitem>
<para>Additionally, you must install the
<package>hp3parclient</package> version 2.0 or
newer from the Python standard library on the
system with the enabled Block Storage Service
volume drivers.</para>
</listitem>
</itemizedlist>
</section>
<section xml:id="hp-3par-supported-ops">
<title>Supported operations</title>
<itemizedlist>
<listitem>
<para>Create volumes.</para>
</listitem>
<listitem>
<para>Delete volumes.</para>
</listitem>
<listitem>
<para>Extend volumes.</para>
</listitem>
<listitem>
<para>Attach volumes.</para>
</listitem>
<listitem>
<para>Detach volumes.</para>
</listitem>
<listitem>
<para>Create snapshots.</para>
</listitem>
<listitem>
<para>Delete snapshots.</para>
</listitem>
<listitem>
<para>Create volumes from snapshots.</para>
</listitem>
<listitem>
<para>Create cloned volumes.</para>
</listitem>
<listitem>
<para>Copy images to volumes.</para>
</listitem>
<listitem>
<para>Copy volumes to images.</para>
</listitem>
</itemizedlist>
<para>Volume type support for both HP 3PAR drivers includes
the ability to set the following capabilities in the
OpenStack Cinder API
<filename>cinder.api.contrib.types_extra_specs</filename>
volume type extra specs extension module:</para>
<itemizedlist>
<listitem>
<para><literal>hp3par:cpg</literal></para>
</listitem>
<listitem>
<para><literal>hp3par:snap_cpg</literal></para>
</listitem>
<listitem>
<para><literal>hp3par:provisioning</literal></para>
</listitem>
<listitem>
<para><literal>hp3par:persona</literal></para>
</listitem>
<listitem>
<para><literal>hp3par:vvs</literal></para>
</listitem>
<listitem>
<para><literal>qos:maxBWS</literal></para>
</listitem>
<listitem>
<para><literal>qos:maxIOPS</literal></para>
</listitem>
</itemizedlist>
<para>To work with the default filter scheduler, the key
values are case sensitive and scoped with
<literal>hp3par:</literal> or <literal>qos:</literal>.
For information about how to set the key-value pairs and
associate them with a volume type, run the following
command:
<screen><prompt>$</prompt> <userinput>
cinder help type-key</userinput></screen>
</para>
<note>
<para>Volumes that are cloned only support extra specs
keys cpg, snap_cpg, provisioning and vvs. The others
are ignored. In addition the comments section of the
cloned volume in the HP 3PAR StoreServ storage array
is not populated.</para>
</note>
<para>The following keys require that the HP 3PAR StoreServ
storage array has a Priority Optimization license
installed.</para>
<itemizedlist>
<listitem>
<para><literal>hp3par:vvs</literal> - The virtual
volume set name that has been predefined by the
Administrator with Quality of Service (QoS) rules
associated to it. If you specify
<literal>hp3par:vvs</literal>, the
<literal>qos:maxIOPS</literal> and
<literal>qos:maxBWS</literal> settings are
ignored.</para>
</listitem>
<listitem>
<para><literal>qos:maxBWS</literal> - The QoS I/O
issue count rate limit in MBs. If not set, the I/O
issue bandwidth rate has no limit.</para>
</listitem>
<listitem>
<para><literal>qos:maxIOPS</literal> - The QoS I/O
issue count rate limit. If not set, the I/O issue
count rate has no limit.</para>
</listitem>
</itemizedlist>
<para>If volume types are not used or a particular key is not
set for a volume type, the following defaults are
used.</para>
<itemizedlist>
<listitem>
<para><literal>hp3par:cpg</literal> - Defaults to the
<literal>hp3par_cpg</literal> setting in the
<filename>cinder.conf</filename> file.</para>
</listitem>
<listitem>
<para><literal>hp3par:snap_cpg</literal> - Defaults to
the <literal>hp3par_snap</literal> setting in the
<filename>cinder.conf</filename> file. If
<literal>hp3par_snap</literal> is not set, it
defaults to the <literal>hp3par_cpg</literal>
setting.</para>
</listitem>
<listitem>
<para><literal>hp3par:provisioning</literal> -
Defaults to thin provisioning, the valid values
are <literal>thin</literal> and
<literal>full</literal>.</para>
</listitem>
<listitem>
<para><literal>hp3par:persona</literal> - Defaults to
the <literal>1 Generic</literal> persona. The
valid values are, <literal>1 Generic</literal>,
<literal>2 - Generic-ALUA</literal>,
<literal>6 - Generic-legacy</literal>,
<literal>7 - HPUX-legacy</literal>, <literal>8
- AIX-legacy</literal>, <literal>9
EGENERA</literal>, <literal>10 -
ONTAP-legacy</literal>, <literal>11
VMware</literal>, and <literal>12 -
OpenVMS</literal>.</para>
</listitem>
</itemizedlist>
</section>
<section xml:id="enable-hp-3par-fibre-channel">
<title>Enable the HP 3PAR Fibre Channel and iSCSI
drivers</title>
<para>The <filename>HP3PARFCDriver</filename> and
<filename>HP3PARISCSIDriver</filename> are installed
with the OpenStack software.</para>
<procedure>
<step>
<para>Install the <filename>hp3parclient</filename>
Python package on the OpenStack Block Storage
system.
<screen>$sudo pip install hp3parclient</screen>
</para>
</step>
<step>
<para>Verify that the HP 3PAR Web Services API server
is enabled and running on the HP 3PAR storage
system.</para>
<substeps>
<step>
<para>Log onto the HP 3PAR storage system with
administrator
access.<screen>#ssh 3paradm@&lt;HP 3PAR IP Address></screen></para>
</step>
<step>
<para>View the current state of the Web
Services API Server.
<screen>#showwsapi</screen><screen><computeroutput>-Service- -State- -HTTP_State-
HTTP_Port -HTTPS_State- HTTPS_Port -Version-</computeroutput></screen><screen><computeroutput>Enabled Active Enabled 8008
Enabled 8080 1.1</computeroutput></screen></para>
</step>
<step>
<para>If the Web Services API Server is
disabled, start
it.<screen>#startwsapi</screen></para>
</step>
</substeps>
</step>
<step>
<para>If the HTTP or HTTPS state is disabled, enable
one of
them.<screen>#setwsapi -http enable </screen> or <screen>#setwsapi -https enable </screen><note>
<para>To stop the Web Services API Server, use
the stopwsapi command. For other options
run the <command>setwsapi h</command>
command.</para>
</note></para>
</step>
<step>
<para>If you are not using an existing CPG, create a
CPG on the HP 3PAR storage system to be used as
the default location for creating volumes.</para>
</step>
<step>
<para>Make the following changes in the
<filename>/etc/cinder/cinder.conf</filename>
file.</para>
<programlisting>
<emphasis role="bold">## REQUIRED SETTINGS</emphasis>
# 3PAR WS API Server URL
hp3par_api_url=https://10.10.0.141:8080/api/v1
# 3PAR Super user username
hp3par_username=3paradm
# 3PAR Super user password
hp3par_password=3parpass
# 3PAR CPG to use for volume creation
hp3par_cpg=OpenStackCPG_RAID5_NL
# IP address of SAN controller for SSH access to the array
san_ip=10.10.22.241
# Username for SAN controller for SSH access to the array
san_login=3paradm
# Password for SAN controller for SSH access to the array
san_password=3parpass
# FIBRE CHANNEL(uncomment the next line to enable the FC driver)
# volume_driver=cinder.volume.drivers.san.hp.hp_3par_fc.HP3PARFCDriver
# iSCSI (uncomment the next line to enable the iSCSI driver and
# hp3par_iscsi_ips or iscsi_ip_address)
#volume_driver=cinder.volume.drivers.san.hp.hp_3par_iscsi.HP3PARISCSIDriver
# iSCSI multiple port configuration
# hp3par_iscsi_ips=10.10.220.253:3261,10.10.222.234
# Still available for single port iSCSI configuration
#iscsi_ip_address=10.10.220.253
<emphasis role="bold">## OPTIONAL SETTINGS</emphasis>
# Enable HTTP debugging to 3PAR
hp3par_debug=False
# The CPG to use for Snapshots for volumes. If empty hp3par_cpg will be used.
hp3par_snap_cpg=OpenStackSNAP_CPG
# Time in hours to retain a snapshot. You can't delete it before this expires.
hp3par_snapshot_retention=48
# Time in hours when a snapshot expires and is deleted. This must be larger than retention.
hp3par_snapshot_expiration=72
</programlisting>
<note>
<para>You can enable only one driver on each
cinder instance unless you enable multiple
back-end support. See the Cinder multiple
back-end support instructions to enable this
feature.</para>
</note>
<note>
<para>You can configure one or more iSCSI
addresses by using the
<option>hp3par_iscsi_ips</option> option.
When you configure multiple addresses, the
driver selects the iSCSI port with the fewest
active volumes at attach time. The IP address
might include an IP port by using a colon
(<literal>:</literal>) to separate the
address from port. If you do not define an IP
port, the default port 3260 is used. Separate
IP addresses with a comma
(<literal>,</literal>). The
<option>iscsi_ip_address</option>/<option>iscsi_port</option>
options might be used as an alternative to
<option>hp3par_iscsi_ips</option> for
single port iSCSI configuration.</para>
</note>
</step>
<step>
<para>Save the changes to the
<filename>cinder.conf</filename> file and
restart the <systemitem class="service"
>cinder-volume</systemitem> service.</para>
</step>
</procedure>
<para>The HP 3PAR Fibre Channel and iSCSI drivers are now
enabled on your OpenStack system. If you experience
problems, review the Block Storage Service log files for
errors.</para>
</section>
</section>