Merge "Dell PowerMax: Fix SnapVx unlink failure"
This commit is contained in:
commit
00e59c7d1d
@ -171,7 +171,7 @@ class PowerMaxProvisionTest(test.TestCase):
|
||||
mock_unlink.assert_called_once_with(
|
||||
array, source_device_id, target_device_id,
|
||||
snap_name, extra_specs, snap_id=self.data.snap_id,
|
||||
list_volume_pairs=None, loop=True)
|
||||
list_volume_pairs=None, loop=True, symforce=False)
|
||||
|
||||
@mock.patch('oslo_service.loopingcall.FixedIntervalLoopingCall',
|
||||
new=test_utils.ZeroIntervalLoopingCall)
|
||||
@ -184,7 +184,8 @@ class PowerMaxProvisionTest(test.TestCase):
|
||||
mock_mod.assert_called_once_with(
|
||||
self.data.array, self.data.device_id, self.data.device_id2,
|
||||
self.data.snap_location['snap_name'], self.data.extra_specs,
|
||||
snap_id=self.data.snap_id, list_volume_pairs=None, unlink=True)
|
||||
snap_id=self.data.snap_id, list_volume_pairs=None, unlink=True,
|
||||
symforce=False)
|
||||
|
||||
mock_mod.reset_mock()
|
||||
self.provision._unlink_volume(
|
||||
@ -194,7 +195,8 @@ class PowerMaxProvisionTest(test.TestCase):
|
||||
mock_mod.assert_called_once_with(
|
||||
self.data.array, self.data.device_id, self.data.device_id2,
|
||||
self.data.snap_location['snap_name'], self.data.extra_specs,
|
||||
snap_id=self.data.snap_id, list_volume_pairs=None, unlink=True)
|
||||
snap_id=self.data.snap_id, list_volume_pairs=None, unlink=True,
|
||||
symforce=False)
|
||||
|
||||
@mock.patch('oslo_service.loopingcall.FixedIntervalLoopingCall',
|
||||
new=test_utils.ZeroIntervalLoopingCall)
|
||||
@ -556,9 +558,12 @@ class PowerMaxProvisionTest(test.TestCase):
|
||||
|
||||
@mock.patch.object(
|
||||
rest.PowerMaxRest, 'get_snap_linked_device_list',
|
||||
side_effect=[[{'targetDevice': tpd.PowerMaxData.device_id2}],
|
||||
[{'targetDevice': tpd.PowerMaxData.device_id2},
|
||||
{'targetDevice': tpd.PowerMaxData.device_id3}]])
|
||||
side_effect=[[{'targetDevice': tpd.PowerMaxData.device_id2,
|
||||
'defined': False}],
|
||||
[{'targetDevice': tpd.PowerMaxData.device_id2,
|
||||
'defined': False},
|
||||
{'targetDevice': tpd.PowerMaxData.device_id3,
|
||||
'defined': False}]])
|
||||
@mock.patch.object(provision.PowerMaxProvision, '_unlink_volume')
|
||||
def test_delete_volume_snap_check_for_links(self, mock_unlink, mock_tgts):
|
||||
self.provision.delete_volume_snap_check_for_links(
|
||||
@ -568,7 +573,8 @@ class PowerMaxProvisionTest(test.TestCase):
|
||||
self.data.array, "", "", self.data.test_snapshot_snap_name,
|
||||
self.data.extra_specs, snap_id=self.data.snap_id,
|
||||
list_volume_pairs=[
|
||||
(self.data.device_id, tpd.PowerMaxData.device_id2)])
|
||||
(self.data.device_id, tpd.PowerMaxData.device_id2)],
|
||||
symforce=False)
|
||||
mock_unlink.reset_mock()
|
||||
self.provision.delete_volume_snap_check_for_links(
|
||||
self.data.array, self.data.test_snapshot_snap_name,
|
||||
|
@ -154,7 +154,12 @@ powermax_opts = [
|
||||
cfg.IntOpt(utils.REST_API_READ_TIMEOUT,
|
||||
default=30, min=1,
|
||||
help='Use this value to specify read '
|
||||
'timeout value (in seconds) for rest call.')]
|
||||
'timeout value (in seconds) for rest call.'),
|
||||
cfg.BoolOpt(utils.SNAPVX_UNLINK_SYMFORCE,
|
||||
default=False,
|
||||
help='Enable SnapVx unlink symforce, which forces '
|
||||
'the operation to execute when normally it is rejected.'),
|
||||
]
|
||||
|
||||
|
||||
CONF.register_opts(powermax_opts, group=configuration.SHARED_CONF_GROUP)
|
||||
@ -195,11 +200,8 @@ class PowerMaxCommon(object):
|
||||
|
||||
self.rest = rest.PowerMaxRest()
|
||||
self.utils = utils.PowerMaxUtils()
|
||||
self.masking = masking.PowerMaxMasking(prtcl, self.rest)
|
||||
self.provision = provision.PowerMaxProvision(self.rest)
|
||||
self.volume_metadata = volume_metadata.PowerMaxVolumeMetadata(
|
||||
self.rest, version, LOG.isEnabledFor(logging.DEBUG))
|
||||
self.migrate = migrate.PowerMaxMigrate(prtcl, self.rest)
|
||||
|
||||
# Configuration/Attributes
|
||||
self.protocol = prtcl
|
||||
@ -220,6 +222,14 @@ class PowerMaxCommon(object):
|
||||
if active_backend_id == utils.PMAX_FAILOVER_START_ARRAY_PROMOTION:
|
||||
self.promotion = True
|
||||
|
||||
# Init provision, masking and migrate instances
|
||||
self.provision = provision.PowerMaxProvision(
|
||||
self.rest, self.configuration)
|
||||
self.masking = masking.PowerMaxMasking(
|
||||
prtcl, self.rest, self.configuration)
|
||||
self.migrate = migrate.PowerMaxMigrate(
|
||||
prtcl, self.rest, self.configuration)
|
||||
|
||||
# Gather environment info
|
||||
self._get_replication_info()
|
||||
self._get_u4p_failover_info()
|
||||
|
@ -39,11 +39,12 @@ class PowerMaxMasking(object):
|
||||
Masking code to dynamically create a masking view.
|
||||
It supports VMAX 3, All Flash and PowerMax arrays.
|
||||
"""
|
||||
def __init__(self, prtcl, rest):
|
||||
def __init__(self, prtcl, rest, configuration):
|
||||
self.protocol = prtcl
|
||||
self.utils = utils.PowerMaxUtils()
|
||||
self.rest = rest
|
||||
self.provision = provision.PowerMaxProvision(self.rest)
|
||||
self.provision = provision.PowerMaxProvision(self.rest,
|
||||
configuration)
|
||||
|
||||
def setup_masking_view(
|
||||
self, serial_number, volume, masking_view_dict, extra_specs):
|
||||
|
@ -34,11 +34,11 @@ class PowerMaxMigrate(object):
|
||||
It supports VMAX 3 and VMAX All Flash and PowerMax arrays.
|
||||
|
||||
"""
|
||||
def __init__(self, prtcl, rest):
|
||||
def __init__(self, prtcl, rest, configuration):
|
||||
self.rest = rest
|
||||
self.utils = utils.PowerMaxUtils()
|
||||
self.masking = masking.PowerMaxMasking(prtcl, self.rest)
|
||||
self.provision = provision.PowerMaxProvision(self.rest)
|
||||
self.masking = masking.PowerMaxMasking(prtcl, self.rest, configuration)
|
||||
self.provision = provision.PowerMaxProvision(self.rest, configuration)
|
||||
|
||||
def do_migrate_if_candidate(
|
||||
self, array, srp, device_id, volume, connector):
|
||||
|
@ -36,9 +36,11 @@ class PowerMaxProvision(object):
|
||||
|
||||
It supports VMAX 3, All Flash and PowerMax arrays.
|
||||
"""
|
||||
def __init__(self, rest):
|
||||
def __init__(self, rest, configuration):
|
||||
self.utils = utils.PowerMaxUtils()
|
||||
self.rest = rest
|
||||
self.snapvx_unlink_symforce = configuration.safe_get(
|
||||
utils.SNAPVX_UNLINK_SYMFORCE) or False
|
||||
|
||||
def create_storage_group(
|
||||
self, array, storagegroup_name, srp, slo, workload,
|
||||
@ -183,6 +185,9 @@ class PowerMaxProvision(object):
|
||||
{'delta': self.utils.get_time_delta(start_time,
|
||||
time.time())})
|
||||
|
||||
def _is_symforce_enabled(self, defined):
|
||||
return self.snapvx_unlink_symforce and (not defined)
|
||||
|
||||
def unlink_snapvx_tgt_volume(
|
||||
self, array, target_device_id, source_device_id, snap_name,
|
||||
extra_specs, snap_id, loop=True):
|
||||
@ -197,20 +202,33 @@ class PowerMaxProvision(object):
|
||||
:param loop: if looping call is required for handling retries
|
||||
"""
|
||||
@coordination.synchronized("emc-snapvx-{src_device_id}")
|
||||
def do_unlink_volume(src_device_id):
|
||||
def do_unlink_volume(src_device_id, symforce=False):
|
||||
LOG.debug("Break snap vx link relationship between: %(src)s "
|
||||
"and: %(tgt)s.",
|
||||
{'src': src_device_id, 'tgt': target_device_id})
|
||||
|
||||
self._unlink_volume(array, src_device_id, target_device_id,
|
||||
snap_name, extra_specs, snap_id=snap_id,
|
||||
list_volume_pairs=None, loop=loop)
|
||||
list_volume_pairs=None, loop=loop,
|
||||
symforce=symforce)
|
||||
|
||||
do_unlink_volume(source_device_id)
|
||||
# Get the link defined status
|
||||
defined = True
|
||||
linked_list = self.rest.get_snap_linked_device_list(
|
||||
array, source_device_id, snap_name, snap_id)
|
||||
for link in linked_list:
|
||||
if target_device_id == link['targetDevice']:
|
||||
if not link['defined']:
|
||||
defined = False
|
||||
break
|
||||
LOG.debug("The link defined status: %s", defined)
|
||||
do_unlink_volume(
|
||||
source_device_id, symforce=self._is_symforce_enabled(defined))
|
||||
|
||||
def _unlink_volume(
|
||||
self, array, source_device_id, target_device_id, snap_name,
|
||||
extra_specs, snap_id=None, list_volume_pairs=None, loop=True):
|
||||
extra_specs, snap_id=None, list_volume_pairs=None, loop=True,
|
||||
symforce=False):
|
||||
"""Unlink a target volume from its source volume.
|
||||
|
||||
:param array: the array serial number
|
||||
@ -221,6 +239,7 @@ class PowerMaxProvision(object):
|
||||
:param snap_id: the unique snap id of the SnapVX
|
||||
:param list_volume_pairs: list of volume pairs, optional
|
||||
:param loop: if looping call is required for handling retries
|
||||
:param symforce: if symforce is enabled
|
||||
:returns: return code
|
||||
"""
|
||||
def _unlink_vol():
|
||||
@ -234,7 +253,8 @@ class PowerMaxProvision(object):
|
||||
if not kwargs['modify_vol_success']:
|
||||
self.rest.modify_volume_snap(
|
||||
array, source_device_id, target_device_id, snap_name,
|
||||
extra_specs, snap_id=snap_id, unlink=True,
|
||||
extra_specs, snap_id=snap_id,
|
||||
unlink=True, symforce=symforce,
|
||||
list_volume_pairs=list_volume_pairs)
|
||||
kwargs['modify_vol_success'] = True
|
||||
except exception.VolumeBackendAPIException:
|
||||
@ -250,7 +270,8 @@ class PowerMaxProvision(object):
|
||||
if not loop:
|
||||
self.rest.modify_volume_snap(
|
||||
array, source_device_id, target_device_id, snap_name,
|
||||
extra_specs, snap_id=snap_id, unlink=True,
|
||||
extra_specs, snap_id=snap_id,
|
||||
unlink=True, symforce=symforce,
|
||||
list_volume_pairs=list_volume_pairs)
|
||||
else:
|
||||
kwargs = {'retries': 0,
|
||||
@ -387,6 +408,7 @@ class PowerMaxProvision(object):
|
||||
:param snap_id: the unique snap id of the SnapVX
|
||||
"""
|
||||
list_device_pairs = []
|
||||
list_device_pairs_defined = True
|
||||
if not isinstance(source_devices, list):
|
||||
source_devices = [source_devices]
|
||||
for source_device in source_devices:
|
||||
@ -398,6 +420,8 @@ class PowerMaxProvision(object):
|
||||
if len(linked_list) == 1:
|
||||
target_device = linked_list[0]['targetDevice']
|
||||
list_device_pairs.append((source_device, target_device))
|
||||
if not linked_list[0]['defined']:
|
||||
list_device_pairs_defined = False
|
||||
else:
|
||||
for link in linked_list:
|
||||
# If a single source volume has multiple targets,
|
||||
@ -405,11 +429,13 @@ class PowerMaxProvision(object):
|
||||
target_device = link['targetDevice']
|
||||
self._unlink_volume(
|
||||
array, source_device, target_device, snap_name,
|
||||
extra_specs, snap_id=snap_id)
|
||||
extra_specs, snap_id=snap_id,
|
||||
symforce=self._is_symforce_enabled(link['defined']))
|
||||
if list_device_pairs:
|
||||
self._unlink_volume(
|
||||
array, "", "", snap_name, extra_specs, snap_id=snap_id,
|
||||
list_volume_pairs=list_device_pairs)
|
||||
list_volume_pairs=list_device_pairs,
|
||||
symforce=self._is_symforce_enabled(list_device_pairs_defined))
|
||||
if source_devices:
|
||||
self.delete_volume_snap(
|
||||
array, snap_name, source_devices, snap_id, restored=False)
|
||||
@ -703,6 +729,14 @@ class PowerMaxProvision(object):
|
||||
self.rest.modify_volume_snap(
|
||||
array, None, None, snap_name, extra_specs, snap_id=snap_id,
|
||||
link=True, list_volume_pairs=list_volume_pairs)
|
||||
# Get the link defined status
|
||||
defined = True
|
||||
for src, dst in list_volume_pairs:
|
||||
linked_list = self.rest.get_snap_linked_device_list(
|
||||
array, src, snap_name, snap_id)
|
||||
if not linked_list[0]['defined']:
|
||||
defined = False
|
||||
break
|
||||
# Unlink the snapshot
|
||||
LOG.debug("Unlinking Snap Vx snapshot: source group: %(srcGroup)s "
|
||||
"targetGroup: %(tgtGroup)s.",
|
||||
@ -710,7 +744,8 @@ class PowerMaxProvision(object):
|
||||
'tgtGroup': target_group_name})
|
||||
self._unlink_volume(
|
||||
array, None, None, snap_name, extra_specs, snap_id=snap_id,
|
||||
list_volume_pairs=list_volume_pairs)
|
||||
list_volume_pairs=list_volume_pairs,
|
||||
symforce=self._is_symforce_enabled(defined))
|
||||
# Delete the snapshot if necessary
|
||||
if delete_snapshot:
|
||||
LOG.debug("Deleting Snap Vx snapshot: source group: %(srcGroup)s "
|
||||
|
@ -2197,7 +2197,7 @@ class PowerMaxRest(object):
|
||||
def modify_volume_snap(self, array, source_id, target_id, snap_name,
|
||||
extra_specs, snap_id=None, link=False, unlink=False,
|
||||
rename=False, new_snap_name=None, restore=False,
|
||||
list_volume_pairs=None, copy=False):
|
||||
list_volume_pairs=None, copy=False, symforce=False):
|
||||
"""Modify a snapvx snapshot
|
||||
|
||||
:param array: the array serial number
|
||||
@ -2248,7 +2248,7 @@ class PowerMaxRest(object):
|
||||
"copy": copy, "action": action,
|
||||
"star": 'false', "force": force,
|
||||
"exact": 'false', "remote": 'false',
|
||||
"symforce": 'false'}
|
||||
"symforce": str(symforce).lower()}
|
||||
elif action == "Rename":
|
||||
operation = 'Rename snapVx snapshot'
|
||||
payload = {"deviceNameListSource": [{"name": source_id}],
|
||||
|
@ -180,6 +180,7 @@ LOAD_LOOKBACK = 'load_look_back'
|
||||
LOAD_LOOKBACK_RT = 'load_look_back_real_time'
|
||||
PORT_GROUP_LOAD_METRIC = 'port_group_load_metric'
|
||||
PORT_LOAD_METRIC = 'port_load_metric'
|
||||
SNAPVX_UNLINK_SYMFORCE = 'snapvx_unlink_symforce'
|
||||
|
||||
# One minute in milliseconds
|
||||
ONE_MINUTE = 60000
|
||||
|
@ -3243,6 +3243,9 @@ options are detailed in the table below.
|
||||
| | | | | load calculation, minimum of 1 |
|
||||
| | | | | maximum of 60 (24 hours). |
|
||||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||
| ``snapvx_unlink_symforce`` | ``True/False`` | ``False`` | | Enable/disable symforce |
|
||||
| | | | | for SnapVx unlink. |
|
||||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||
| ``port_group_load_metric`` | See below | ``PercentBusy`` | | Metric used for port group load |
|
||||
| | | | | calculation. |
|
||||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||
|
@ -0,0 +1,32 @@
|
||||
---
|
||||
fixes:
|
||||
- |
|
||||
Dell PowerMax Driver `Bug #2045230
|
||||
<https://bugs.launchpad.net/cinder/+bug/2045230>`_: Fixed
|
||||
the issue that Dell PowerMax SnapVx link fails as the linked device is not
|
||||
yet fully defined.
|
||||
|
||||
Previously, the below operations could fail if the linked device was not
|
||||
yet fully defined at the time of the call.
|
||||
Now, when ``snapvx_unlink_symforce`` is enabled, those operations are not
|
||||
interrupted by not fully defined devices.
|
||||
|
||||
By default, ``snapvx_unlink_symforce`` is ``False``. Use extreme caution
|
||||
with this option. If used when a link is copy in progress or when a restore
|
||||
is restore in progress, this will cause an incomplete copy and data on the
|
||||
copy target would not be usable.
|
||||
|
||||
Impacted operations:
|
||||
|
||||
* Clone a volume
|
||||
* Create a volume from a snapshot
|
||||
* Create volume snapshots
|
||||
* Delete volume snapshots
|
||||
* Revert volume to snapshot
|
||||
* Create generic volume group from source
|
||||
* Unmanage volumes
|
||||
upgrade:
|
||||
- |
|
||||
Dell PowerMax Driver: introduced a new configuration option,
|
||||
``snapvx_unlink_symforce``, to address Bug #2045230. See the Bug Fixes
|
||||
section for details.
|
Loading…
Reference in New Issue
Block a user