The Dell EMC PowerMax Cinder driver supports the VMAX-3 hybrid series, VMAX
|
||||
All-Flash series and the PowerMax arrays.
|
||||
|
||||
The array operating system software, Solutions Enabler 9.2.x series, and
|
||||
Unisphere for PowerMax 9.2.x series are required to run Dell EMC PowerMax
|
||||
Cinder driver.
|
||||
The array operating system software, Solutions Enabler 9.2.1 series, and
|
||||
Unisphere for PowerMax 9.2.1 series are required to run Dell EMC PowerMax
|
||||
Cinder driver for the Wallaby release. Please refer to support-matrix-table_
|
||||
for the support matrix of previous OpenStack versions.
|
||||
|
||||
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
|
||||
(login is required). See the ``Dell EMC Solutions Enabler 9.2.x Installation
|
||||
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
|
||||
Guide`` at the `Dell EMC Support`_ site.
|
||||
(login is required). See the `Dell EMC Solutions Enabler 9.2.1 Installation
|
||||
and Configuration Guide` and `Dell EMC Unisphere for PowerMax Installation
|
||||
Guide` at the `Dell EMC Support`_ site.
|
||||
|
||||
.. note::
|
||||
|
||||
While it is not explicitly documented which OS versions should be
|
||||
installed on a particular array, it is recommended to install the latest
|
||||
PowerMax OS as supported by Unisphere for PowerMax, that the PowerMax
|
||||
driver supports for a given OpenStack release.
|
||||
At the time each OpenStack release, support-matrix-table_ was the
|
||||
recommended PowerMax management software and OS combinations. Please
|
||||
reach out your local PowerMax representative to see if these versions
|
||||
are still valid.
|
||||
|
||||
|
||||
.. _support-matrix-table:
|
||||
|
||||
.. table:: PowerMax Management software and OS for OpenStack release
|
||||
|
||||
+-----------+------------------------+-------------+
|
||||
| OpenStack | Unisphere for PowerMax | PowerMax OS |
|
||||
+===========+========================+=============+
|
||||
| Wallaby | 9.2.1 | 5978.711 |
|
||||
+-----------+------------------------+-------------+
|
||||
| Victoria | 9.2.x | 5978.669 |
|
||||
+-----------+------------------------+-------------+
|
||||
| Ussuri | 9.1.x | 5978.479 |
|
||||
@ -56,11 +64,21 @@ Guide`` at the `Dell EMC Support`_ site.
|
||||
| Stein | 9.0.x | 5978.221 |
|
||||
+-----------+------------------------+-------------+
|
||||
|
||||
However, a Hybrid array can only run HyperMax OS 5977, and is still
|
||||
supported until further notice. Some functionality will not be available
|
||||
in older versions of the OS. If in any doubt, please contact your customer
|
||||
.. note::
|
||||
|
||||
A Hybrid array can only run HyperMax OS 5977, and is still supported until
|
||||
further notice. Some functionality will not be available in older versions
|
||||
of the OS. If in any doubt, please contact your local PowerMax
|
||||
representative.
|
||||
|
||||
.. note::
|
||||
|
||||
Newer versions of Unisphere for PowerMax and PowerMax OS are not
|
||||
retrospectively tested on older versions of OpenStack. If it is necessary
|
||||
to upgrade, the older REST endpoints will be used. For example, in Ussuri,
|
||||
if upgrading to Unisphere for PowerMax 9.2, the older ``91`` endpoints will
|
||||
be used.
|
||||
|
||||
|
||||
|
||||
Required PowerMax software suites for OpenStack
|
||||
@ -321,6 +339,22 @@ Child storage groups:
|
||||
For VMAX All Flash with PowerMax OS (5978) or greater, workload if set will
|
||||
be ignored and set to NONE.
|
||||
|
||||
.. _my-table:
|
||||
|
||||
.. table:: Replication storage group naming conventions
|
||||
|
||||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||||
| Default storage group | Attached child storage group | Management Group | Replication Type |
|
||||
+============================+=================================+================================+====================+
|
||||
| OS-[SRP]-[SL]-[WL]-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG] | N/A | None |
|
||||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||||
| OS-[SRP]-[SL]-[WL]-RE-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RE | N/A | Synchronous |
|
||||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||||
| OS-[SRP]-[SL]-[WL]-RA-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RA | OS-[RDFG]-Asynchronous-rdf-sg | Asynchronous |
|
||||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||||
| OS-[SRP]-[SL]-[WL]-RM-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RM | OS-[RDFG]-Metro-rdf-sg | Metro |
|
||||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||||
|
||||
|
||||
PowerMax driver integration
|
||||
===========================
|
||||
@ -336,13 +370,13 @@ PowerMax driver integration
|
||||
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
|
||||
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
|
||||
(eManagement) container application. See the ``Dell EMC Solutions Enabler
|
||||
9.2.x Installation and Configuration Guide`` on `Dell EMC Support`_ for
|
||||
9.2.1 Installation and Configuration Guide`` on `Dell EMC Support`_ for
|
||||
more details.
|
||||
|
||||
.. note::
|
||||
|
||||
You must discover storage arrays before you can use the PowerMax drivers.
|
||||
Follow instructions in ``Dell EMC Solutions Enabler 9.2.x Installation
|
||||
Follow instructions in ``Dell EMC Solutions Enabler 9.2.1 Installation
|
||||
and Configuration Guide`` on `Dell EMC Support`_ for more details.
|
||||
|
||||
#. Download Unisphere from `Dell EMC Support`_ and install it.
|
||||
@ -351,7 +385,7 @@ PowerMax driver integration
|
||||
- i.e., on the same server running Solutions Enabler; on a server
|
||||
connected to the Solutions Enabler server; or using the eManagement
|
||||
container application (containing Solutions Enabler and Unisphere for
|
||||
PowerMax). See ``Dell EMC Solutions Enabler 9.2.x Installation and
|
||||
PowerMax). See ``Dell EMC Solutions Enabler 9.2.1 Installation and
|
||||
Configuration Guide`` at `Dell EMC Support`_.
|
||||
|
||||
|
||||
@ -1051,10 +1085,10 @@ Prerequisites - PowerMax
|
||||
|
||||
Volume is created against volume type and there is no QoS change.
|
||||
|
||||
10. iSCSI multi-pathing support
|
||||
-------------------------------
|
||||
10. Multi-pathing support
|
||||
-------------------------
|
||||
|
||||
- Install ``open-iscsi`` on all nodes on your system
|
||||
- Install ``open-iscsi`` on all nodes on your system if on an iSCSI setup.
|
||||
- Do not install EMC PowerPath as they cannot co-exist with native multi-path
|
||||
software
|
||||
- Multi-path tools must be installed on all Nova compute nodes
|
||||
@ -1115,21 +1149,37 @@ performance. Log in as a privileged user and make the following changes to
|
||||
You may need to reboot the host after installing the MPIO tools or restart
|
||||
iSCSI and multi-path services.
|
||||
|
||||
On Ubuntu:
|
||||
On Ubuntu iSCSI:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
# service open-iscsi restart
|
||||
# service multipath-tools restart
|
||||
|
||||
On Ubuntu FC
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
# service multipath-tools restart
|
||||
|
||||
|
||||
On openSUSE, SUSE Linux Enterprise Server, Red Hat Enterprise Linux, and
|
||||
CentOS:
|
||||
CentOS iSCSI:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
# systemctl restart open-iscsi
|
||||
# systemctl restart multipath-tools
|
||||
|
||||
|
||||
On openSUSE, SUSE Linux Enterprise Server, Red Hat Enterprise Linux, and
|
||||
CentOS FC:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
# systemctl restart multipath-tools
|
||||
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ lsblk
|
||||
@ -1622,12 +1672,16 @@ Requirements
|
||||
Configuration
|
||||
~~~~~~~~~~~~~
|
||||
|
||||
The following configuration changes need to be made in ``cinder.conf`` in order
|
||||
to support the failover to secondary Unisphere. Cinder services will need to
|
||||
be restarted for changes to take effect.
|
||||
The following configuration changes need to be made in ``cinder.conf`` under
|
||||
the PowerMax backend stanza in order to support the failover to secondary
|
||||
Unisphere. Cinder services will need to be restarted for changes to take
|
||||
effect.
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
[POWERMAX_1]
|
||||
...
|
||||
|
||||
u4p_failover_timeout = 30
|
||||
u4p_failover_retries = 3
|
||||
u4p_failover_backoff_factor = 1
|
||||
@ -1684,6 +1738,14 @@ metadata.
|
||||
+----------------+----------------+--------------+--------------+-------------+
|
||||
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
|
||||
+================+================+==============+==============+=============+
|
||||
| 5978.711 | 5978.711 | Y | Y | Y |
|
||||
+----------------+----------------+--------------+--------------+-------------+
|
||||
| 5978.711 | 5978.669 | Y | Y | Y |
|
||||
+----------------+----------------+--------------+--------------+-------------+
|
||||
| 5978.711 | 5978.444 | Y | Y | Y |
|
||||
+----------------+----------------+--------------+--------------+-------------+
|
||||
| 5978.711 | 5978.221 | Y | Y | N |
|
||||
+----------------+----------------+--------------+--------------+-------------+
|
||||
| 5978.669 | 5978.669 | Y | Y | Y |
|
||||
+----------------+----------------+--------------+--------------+-------------+
|
||||
| 5978.669 | 5978.444 | Y | Y | Y |
|
||||
@ -1897,6 +1959,33 @@ Cinder supported operations
|
||||
Volume replication support
|
||||
--------------------------
|
||||
|
||||
|
||||
.. note::
|
||||
|
||||
A mix of ``RDF1+TDEV`` and ``TDEV`` volumes should not exist in the same
|
||||
storage group. This can happen on a cleanup operation after breaking the
|
||||
pair and a 'TDEV' remains in the storage group on either the local or
|
||||
remote array. If this happens, remove the volume from the storage
|
||||
group so that further replicated volume operations can continue.
|
||||
For example, Remove ``TDEV`` from ``OS-[SRP]-[SL]-[WL]-RA-SG``.
|
||||
|
||||
.. note::
|
||||
|
||||
Replication storage groups should exist on both local and remote array but
|
||||
never on just one. For example, if OS-[SRP]-[SL]-[WL]-RA-SG exists on
|
||||
local array A it must also exist on remote array B. If this condition
|
||||
does not hold, further replication operations will fail. This applies
|
||||
to management storage groups in the case of ``Asynchronous`` and ``Metro``
|
||||
modes also. See :ref:`my-table`.
|
||||
|
||||
.. note::
|
||||
|
||||
The number of devices in replication storage groups in both local and
|
||||
remote arrays should be same. This also applies to management storage
|
||||
groups in ``Asynchronous`` and ``Metro`` modes. See :ref:`my-table`.
|
||||
|
||||
|
||||
|
||||
Configure a single replication target
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
@ -2034,7 +2123,7 @@ Configure a single replication target
|
||||
``replication_device`` parameter has been entered in the PowerMax
|
||||
backend entry in the ``cinder.conf``, a corresponding volume type
|
||||
needs to be created ``replication_enabled`` property set. See
|
||||
above `6. Create volume types`_ for details.
|
||||
above `Create volume types`_ for details.
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
@ -2497,7 +2586,7 @@ retype, follow these steps:
|
||||
another, use volume retype with the migration-policy to on-demand. The
|
||||
target volume type should have the same volume_backend_name configured and
|
||||
should have the desired pool_name to which you are trying to retype to
|
||||
(please refer to `6. Create volume types`_ for details).
|
||||
(please refer to `Create volume types`_ for details).
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
@ -2919,6 +3008,7 @@ List manageable volume is filtered by:
|
||||
- Volume should not be a part of an RDF session
|
||||
- Volume should not be a SnapVX Target
|
||||
- Volume identifier should not begin with ``OS-``.
|
||||
- Volume should not be in more than one storage group.
|
||||
|
||||
Manageable snaphots
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
@ -3146,3 +3236,4 @@ following the setup instructions above, are supported with a few exceptions:
|
||||
.. _volume backup: https://docs.openstack.org/cinder/latest/configuration/block-storage/backup-drivers.html
|
||||
.. _volume backup CLI: https://docs.openstack.org/python-openstackclient/latest/cli/command-objects/volume-backup.html
|
||||
.. _PyU4V: https://pyu4v.readthedocs.io/en/latest/
|
||||
.. _Create volume types: `6. Create volume types`_
|
||||
|