Merge "PowerMax Docs - Victoria new features and supported software"
This commit is contained in:
commit
663ed6787b
@ -28,12 +28,12 @@ System requirements and licensing
|
|||||||
The Dell EMC PowerMax Cinder driver supports the VMAX-3 hybrid series, VMAX
|
The Dell EMC PowerMax Cinder driver supports the VMAX-3 hybrid series, VMAX
|
||||||
All-Flash series and the PowerMax arrays.
|
All-Flash series and the PowerMax arrays.
|
||||||
|
|
||||||
The array operating system software, Solutions Enabler 9.1.x series, and
|
The array operating system software, Solutions Enabler 9.2.x series, and
|
||||||
Unisphere for PowerMax 9.1.x series are required to run Dell EMC PowerMax
|
Unisphere for PowerMax 9.2.x series are required to run Dell EMC PowerMax
|
||||||
Cinder driver.
|
Cinder driver.
|
||||||
|
|
||||||
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
|
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
|
||||||
(login is required). See the ``Dell EMC Solutions Enabler 9.1.x Installation
|
(login is required). See the ``Dell EMC Solutions Enabler 9.2.x Installation
|
||||||
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
|
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
|
||||||
Guide`` at the `Dell EMC Support`_ site.
|
Guide`` at the `Dell EMC Support`_ site.
|
||||||
|
|
||||||
@ -47,6 +47,8 @@ Guide`` at the `Dell EMC Support`_ site.
|
|||||||
+-----------+------------------------+-------------+
|
+-----------+------------------------+-------------+
|
||||||
| OpenStack | Unisphere for PowerMax | PowerMax OS |
|
| OpenStack | Unisphere for PowerMax | PowerMax OS |
|
||||||
+===========+========================+=============+
|
+===========+========================+=============+
|
||||||
|
| Victoria | 9.2.x | 5978.669 |
|
||||||
|
+-----------+------------------------+-------------+
|
||||||
| Ussuri | 9.1.x | 5978.479 |
|
| Ussuri | 9.1.x | 5978.479 |
|
||||||
+-----------+------------------------+-------------+
|
+-----------+------------------------+-------------+
|
||||||
| Train | 9.1.x | 5978.444 |
|
| Train | 9.1.x | 5978.444 |
|
||||||
@ -195,7 +197,17 @@ PowerMax drivers also support the following features:
|
|||||||
- Multiple replication devices
|
- Multiple replication devices
|
||||||
- PowerMax array and storage group tagging
|
- PowerMax array and storage group tagging
|
||||||
- Short host name and port group templates
|
- Short host name and port group templates
|
||||||
|
- Snap id support
|
||||||
|
- Seamless Live Migration from SMI-S support
|
||||||
|
- Port group & port performance load balancing
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
In certain cases, when creating a volume from a source snapshot or
|
||||||
|
source volume, subsequent operations using the volumes may fail due to
|
||||||
|
a missing snap_name exception. A manual refresh on the connected
|
||||||
|
Unisphere instance or waiting until another operation automatically
|
||||||
|
refreshes the connected Unisphere instance, will alleviate this issue.
|
||||||
|
|
||||||
PowerMax naming conventions
|
PowerMax naming conventions
|
||||||
===========================
|
===========================
|
||||||
@ -324,13 +336,13 @@ PowerMax driver integration
|
|||||||
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
|
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
|
||||||
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
|
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
|
||||||
(eManagement) container application. See the ``Dell EMC Solutions Enabler
|
(eManagement) container application. See the ``Dell EMC Solutions Enabler
|
||||||
9.1.x Installation and Configuration Guide`` on `Dell EMC Support`_ for
|
9.2.x Installation and Configuration Guide`` on `Dell EMC Support`_ for
|
||||||
more details.
|
more details.
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
You must discover storage arrays before you can use the PowerMax drivers.
|
You must discover storage arrays before you can use the PowerMax drivers.
|
||||||
Follow instructions in ``Dell EMC Solutions Enabler 9.1.x Installation
|
Follow instructions in ``Dell EMC Solutions Enabler 9.2.x Installation
|
||||||
and Configuration Guide`` on `Dell EMC Support`_ for more details.
|
and Configuration Guide`` on `Dell EMC Support`_ for more details.
|
||||||
|
|
||||||
#. Download Unisphere from `Dell EMC Support`_ and install it.
|
#. Download Unisphere from `Dell EMC Support`_ and install it.
|
||||||
@ -339,7 +351,7 @@ PowerMax driver integration
|
|||||||
- i.e., on the same server running Solutions Enabler; on a server
|
- i.e., on the same server running Solutions Enabler; on a server
|
||||||
connected to the Solutions Enabler server; or using the eManagement
|
connected to the Solutions Enabler server; or using the eManagement
|
||||||
container application (containing Solutions Enabler and Unisphere for
|
container application (containing Solutions Enabler and Unisphere for
|
||||||
PowerMax). See ``Dell EMC Solutions Enabler 9.1.x Installation and
|
PowerMax). See ``Dell EMC Solutions Enabler 9.2.x Installation and
|
||||||
Configuration Guide`` at `Dell EMC Support`_.
|
Configuration Guide`` at `Dell EMC Support`_.
|
||||||
|
|
||||||
|
|
||||||
@ -366,14 +378,6 @@ complex and open-zoning would raise security concerns.
|
|||||||
4. Configure block storage in cinder.conf
|
4. Configure block storage in cinder.conf
|
||||||
-----------------------------------------
|
-----------------------------------------
|
||||||
|
|
||||||
.. note::
|
|
||||||
|
|
||||||
VMAX driver was rebranded to PowerMax in Stein, so some of the driver
|
|
||||||
specific tags have also changed. Legacy tags like ``vmax_srp``,
|
|
||||||
``vmax_array``, ``vmax_service_level`` and ``vmax_port_group``, as well
|
|
||||||
as the old driver location, will continue to work until the 'V' release.
|
|
||||||
|
|
||||||
|
|
||||||
.. config-table::
|
.. config-table::
|
||||||
:config-target: PowerMax
|
:config-target: PowerMax
|
||||||
|
|
||||||
@ -393,11 +397,15 @@ complex and open-zoning would raise security concerns.
|
|||||||
PowerMax ``PortGroups`` must be pre-configured to expose volumes managed
|
PowerMax ``PortGroups`` must be pre-configured to expose volumes managed
|
||||||
by the array. Port groups can be supplied in ``cinder.conf``, or
|
by the array. Port groups can be supplied in ``cinder.conf``, or
|
||||||
can be specified as an extra spec ``storagetype:portgroupname`` on a
|
can be specified as an extra spec ``storagetype:portgroupname`` on a
|
||||||
volume type. The latter gives the user more control. When a dynamic
|
volume type. If a port group is set on a volume type as an extra
|
||||||
masking view is created by the PowerMax driver, if there is no port group
|
specification it takes precedence over any port groups set in
|
||||||
specified as an extra specification, the port group is chosen randomly
|
``cinder.conf``. For more information on port and port group selection
|
||||||
from the PortGroup list, to evenly distribute load across the set of
|
please see the section ``port group & port load balancing``.
|
||||||
groups provided.
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
PowerMax ``SRP`` cannot be changed once configured and in-use. SRP renaming
|
||||||
|
on the PowerMax array is not supported.
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
@ -1423,7 +1431,8 @@ migration.
|
|||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
$ openstack server migrate --live HostA \
|
$ openstack server migrate --os-compute-api-version 2.30 \
|
||||||
|
--live-migration --host HostA \
|
||||||
server_lm_1
|
server_lm_1
|
||||||
|
|
||||||
#. Run the command on step 3 above when the instance is back in available
|
#. Run the command on step 3 above when the instance is back in available
|
||||||
@ -1675,6 +1684,12 @@ metadata.
|
|||||||
+----------------+----------------+--------------+--------------+-------------+
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
|
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
|
||||||
+================+================+==============+==============+=============+
|
+================+================+==============+==============+=============+
|
||||||
|
| 5978.669 | 5978.669 | Y | Y | Y |
|
||||||
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
|
| 5978.669 | 5978.444 | Y | Y | Y |
|
||||||
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
|
| 5978.669 | 5978.221 | Y | Y | N |
|
||||||
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
| 5978.444 | 5978.444 | Y | Y | Y |
|
| 5978.444 | 5978.444 | Y | Y | Y |
|
||||||
+----------------+----------------+--------------+--------------+-------------+
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
| 5978.444 | 5978.221 | Y | Y | N |
|
| 5978.444 | 5978.221 | Y | Y | N |
|
||||||
@ -1693,14 +1708,15 @@ Assumptions, restrictions and prerequisites
|
|||||||
- Where one array is a lower uCode than the other, the environment is limited
|
- Where one array is a lower uCode than the other, the environment is limited
|
||||||
to functionality of that of the lowest uCode level, i.e. if R1 is 5978.444
|
to functionality of that of the lowest uCode level, i.e. if R1 is 5978.444
|
||||||
and R2 is 5978.221, expanding a metro volume is not supported, both R1 and
|
and R2 is 5978.221, expanding a metro volume is not supported, both R1 and
|
||||||
R2 need to be on 5978.444 uCode.
|
R2 need to be on 5978.444 uCode at a minimum.
|
||||||
|
|
||||||
|
|
||||||
20. PowerMax array and storage group tagging
|
20. PowerMax array and storage group tagging
|
||||||
--------------------------------------------
|
--------------------------------------------
|
||||||
|
|
||||||
Unisphere for PowerMax 9.1 supports tagging of storage groups and arrays,
|
Unisphere for PowerMax 9.1 and later supports tagging of storage groups and
|
||||||
so the user can give their own 'tag' for ease of searching and/or grouping.
|
arrays, so the user can give their own 'tag' for ease of searching and/or
|
||||||
|
grouping.
|
||||||
|
|
||||||
Assumptions, restrictions and prerequisites
|
Assumptions, restrictions and prerequisites
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
@ -1760,6 +1776,15 @@ group needs to be truncated to 12 characters or less. This functionality
|
|||||||
offers a little bit more flexibility to determine how these truncated
|
offers a little bit more flexibility to determine how these truncated
|
||||||
components should look.
|
components should look.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
Once the port group and short host name have been overridden with any
|
||||||
|
new format, it is not possible to return to the default format or change
|
||||||
|
to another format if any volumes are in an attached state. This is because
|
||||||
|
there is no way to determine the overridden format once
|
||||||
|
``powermax_short_host_name_template` or ``powermax_port_group_name_template``
|
||||||
|
have been removed or changed.
|
||||||
|
|
||||||
Assumptions, restrictions, and prerequisites
|
Assumptions, restrictions, and prerequisites
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
@ -1851,6 +1876,21 @@ Assumptions, restrictions, and prerequisites
|
|||||||
+-----------------------------------+-------------------------------------+------------------------------------+
|
+-----------------------------------+-------------------------------------+------------------------------------+
|
||||||
|
|
||||||
|
|
||||||
|
21. Snap ids replacing generations
|
||||||
|
----------------------------------
|
||||||
|
|
||||||
|
Snap ids were introduced to the PowerMax in microcde 5978.669.669 and
|
||||||
|
Unisphere for PowerMax 9.2. Generations existed previously and could cause
|
||||||
|
stale data if deleted out of sequence, even though we locked against this
|
||||||
|
occurence. This happened when the newer generation(s) inherited its deleted
|
||||||
|
predecessors generation number. So in a series of 0, 1, 2 and 3 generations,
|
||||||
|
if generation 1 gets deleted, generation 2 now becomes generation 1 and
|
||||||
|
generation 3 becomes generation 2 and so on down the line.
|
||||||
|
Snap ids are unique to each snapVX and will not change once assigned at
|
||||||
|
creation so out of sequence deletions are no longer an issue.
|
||||||
|
Generations will remain for arrays with microcode less than 5978.669.669.
|
||||||
|
|
||||||
|
|
||||||
Cinder supported operations
|
Cinder supported operations
|
||||||
===========================
|
===========================
|
||||||
|
|
||||||
@ -1893,6 +1933,27 @@ Configure a single replication target
|
|||||||
.. note::
|
.. note::
|
||||||
The PowerMax Cinder drivers do not support Cascaded SRDF.
|
The PowerMax Cinder drivers do not support Cascaded SRDF.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
The transmit idle functionality must be disabled on the R2 array for
|
||||||
|
Asynchronous rdf groups. If this is not disabled it will prevent failover
|
||||||
|
promotion in the event of access to the R1 array being lost.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# symrdf -sid <sid> -rdfg <rdfg> set rdfa -transmit_idle off
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
When creating RDF enabled volumes, if there are existing volumes in the
|
||||||
|
target storage group, all rdf pairs related to that storage group must
|
||||||
|
have the same rdf state i.e. rdf pair states must be consistent across
|
||||||
|
all volumes in a storage group when attempting to create a new replication
|
||||||
|
enabled volume. If mixed rdf pair states are found during a volume creation
|
||||||
|
attempt, an error will be raised by the rdf state validation checks.
|
||||||
|
In this event, please wait until all volumes in the storage group have
|
||||||
|
reached a consistent state.
|
||||||
|
|
||||||
#. Enable replication in ``/etc/cinder/cinder.conf``.
|
#. Enable replication in ``/etc/cinder/cinder.conf``.
|
||||||
To enable the replication functionality in PowerMax Cinder driver, it is
|
To enable the replication functionality in PowerMax Cinder driver, it is
|
||||||
necessary to create a replication volume-type. The corresponding
|
necessary to create a replication volume-type. The corresponding
|
||||||
@ -2171,14 +2232,6 @@ host command to failover to the configured target:
|
|||||||
|
|
||||||
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION
|
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION
|
||||||
|
|
||||||
.. note::
|
|
||||||
|
|
||||||
In cases where multiple replication devices are enabled, a backend_id must
|
|
||||||
be specified during initial failover. This can be achieved by appending
|
|
||||||
``--backend_id <backend_id>`` to the failover command above. The backend_id
|
|
||||||
specified must match one of the backend_ids specified in ``cinder.conf's``
|
|
||||||
``replication_device's``.
|
|
||||||
|
|
||||||
After issuing ``cinder failover-host`` Cinder will set the R2 array as the
|
After issuing ``cinder failover-host`` Cinder will set the R2 array as the
|
||||||
target array for Cinder, however, to get existing instances to use this new
|
target array for Cinder, however, to get existing instances to use this new
|
||||||
array and paths to volumes it is necessary to first shelve Nova instances and
|
array and paths to volumes it is necessary to first shelve Nova instances and
|
||||||
@ -2207,6 +2260,164 @@ data paths between Nova instances and their corresponding back end volumes.
|
|||||||
Once reverted to the default backend volume and snapshot provisioning
|
Once reverted to the default backend volume and snapshot provisioning
|
||||||
operations can continue as normal.
|
operations can continue as normal.
|
||||||
|
|
||||||
|
Failover promotion
|
||||||
|
~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
Failover promotion can be used to transfer all existing RDF enabled volumes
|
||||||
|
to the R2 array and overwrite any references to the original R1 array. This
|
||||||
|
can be used in the event of total R1 array failure or in other cases where
|
||||||
|
an array transfer is warranted. If the R1 array is online and working and the
|
||||||
|
RDF links are still enabled the failover promotion will automatically delete
|
||||||
|
rdf pairs as necessary. If the R1 array or the link to the R1 array is down,
|
||||||
|
a half deletepair must be issued manually for those volumes during the
|
||||||
|
failover promotion.
|
||||||
|
|
||||||
|
1. Issue failover command:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# cinder failover-host <host>
|
||||||
|
|
||||||
|
2. Enable array promotion:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# cinder failover-host --backend_id=pmax_failover_start_array_promotion <host>
|
||||||
|
|
||||||
|
3. View and re-enable the cinder service
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# cinder service-list
|
||||||
|
# cinder service-enable <host> <binary>
|
||||||
|
|
||||||
|
4. Remove all volumes from volume groups
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# cinder --os-volume-api-version 3.13 group-update --remove-volumes <Vol1ID, etc..> <volume_group_name>
|
||||||
|
|
||||||
|
5. Detach all volumes that are attached to instances
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# openstack server remove volume <instance_id> <volume_id>
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
Deleting the instance will call a detach volume for each attached volume.
|
||||||
|
A terminate connection can be issued manually using the following command
|
||||||
|
for volumes that are stuck in the attached state without an instance.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# cinder --os-volume-api-version 3.50 attachment-delete <attachment_id>
|
||||||
|
|
||||||
|
6. Delete all remaining instances
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# nova delete <instance_id>
|
||||||
|
|
||||||
|
7. Create new volume types
|
||||||
|
|
||||||
|
New volume types must be created with references to the remote array. All new
|
||||||
|
volume types must adhere to the following guidelines:
|
||||||
|
|
||||||
|
.. code-block:: text
|
||||||
|
|
||||||
|
1. Uses the same workload, SLO & compression setting as the previous R1 volume type.
|
||||||
|
2. Uses the remote array instead of the primary for its pool name.
|
||||||
|
3. Uses the same volume_backend_name as the previous volume type.
|
||||||
|
4. Must not have replication enabled.
|
||||||
|
|
||||||
|
Example existing volume type extra specs.
|
||||||
|
|
||||||
|
.. code-block:: text
|
||||||
|
|
||||||
|
pool_name='Gold+None+SRP_1+000297900330', replication_enabled='<is> True',
|
||||||
|
storagetype:replication_device_backend_id='async-rep-1', volume_backend_name='POWERMAX_ISCSI_NONE'
|
||||||
|
|
||||||
|
Example new volume type extra specs.
|
||||||
|
|
||||||
|
.. code-block:: text
|
||||||
|
|
||||||
|
pool_name='Gold+None+SRP_1+000197900049', volume_backend_name='POWERMAX_ISCSI_NONE'
|
||||||
|
|
||||||
|
8. Retype volumes to new volume types
|
||||||
|
|
||||||
|
Additional checks will be performed during failover promotion retype to ensure
|
||||||
|
workload, compression and slo settings meet the criteria specified above when
|
||||||
|
creating the new volume types.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# cinder retype --migration-policy on-demand <volume> <volume_type>
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
If the volumes RDF links are offline during this retype then a half deletepair
|
||||||
|
must be performed manually after retype. Please reference section 8.a. below
|
||||||
|
for guidance on this process.
|
||||||
|
|
||||||
|
8.a. Retype and RDF half deletepair
|
||||||
|
|
||||||
|
In instances where the rdf links are offline and rdf pairs have been set to
|
||||||
|
partitioned state there are additional requirements. In that scenario the
|
||||||
|
following order should be adhered to:
|
||||||
|
|
||||||
|
.. code-block:: text
|
||||||
|
|
||||||
|
1. Retype all Synchronous volumes.
|
||||||
|
2. Half_deletepair all Synchronous volumes using the default storage group.
|
||||||
|
3. Retype all Asynchronous volumes.
|
||||||
|
4. Half_deletepair all Asynchronous volumes using their management storage group.
|
||||||
|
5. Retype all Metro volumes.
|
||||||
|
6. Half_deletepair all Metro volumes using their management storage group.
|
||||||
|
7. Delete the Asynchronous and Metro management storage groups.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
A half deletepair cannot be performed on Metro enabled volumes unless the
|
||||||
|
symforce option has been enabled in the symapi options. In symapi/config/options
|
||||||
|
uncomment and set 'SYMAPI_ALLOW_RDF_SYMFORCE = True'.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# symrdf -sid <sid> -sg <sg> -rdfg <rdfg> -force -symforce half_deletepair
|
||||||
|
|
||||||
|
9. Issue failback
|
||||||
|
|
||||||
|
Issuing the failback command will disable both the failover and promotion
|
||||||
|
flags. Please ensure all volumes have been retyped and all replication pairs
|
||||||
|
have been deleted before issuing this command.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# cinder failover-host --backend_id default <host>
|
||||||
|
|
||||||
|
10. Update cinder.conf
|
||||||
|
|
||||||
|
Update the cinder.conf file to include details for the new primary array. For
|
||||||
|
more information please see the Configure block storage in cinder.conf section
|
||||||
|
of this documentation.
|
||||||
|
|
||||||
|
11. Restart the cinder services
|
||||||
|
|
||||||
|
Restart the cinder volume service to allow it to detect the changes made to
|
||||||
|
the cinder.conf file.
|
||||||
|
|
||||||
|
12. Set Metro volumes to ready state
|
||||||
|
|
||||||
|
Metro volumes will be set to a Not Ready state after performing rdf pair
|
||||||
|
cleanup. Set these volumes back to Ready state to allow them to be attached
|
||||||
|
to instances. The U4P instance must be restarted for this change to be
|
||||||
|
detected.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# symdev -sid <sid> ready -devs <dev_id1, dev_id2>
|
||||||
|
|
||||||
Asynchronous and metro replication management groups
|
Asynchronous and metro replication management groups
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
@ -2256,13 +2467,13 @@ retype, follow these steps:
|
|||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
The Ussuri release of OpenStack supports retyping in-use volumes to and from
|
From the Ussuri release of OpenStack the PowerMax driver supports retyping
|
||||||
replication enabled volume types with limited exception of volumes with
|
in-use volumes to and from replication enabled volume types with limited
|
||||||
Metro replication enabled. To retype to a volume-type that is Metro enabled
|
exception of volumes with Metro replication enabled. To retype to a
|
||||||
the volume **must** first be detached then retyped. The reason for this is
|
volume-type that is Metro enabled the volume **must** first be detached
|
||||||
so the paths from the instance to the Metro R1 & R2 volumes must be
|
then retyped. The reason for this is so the paths from the instance to the
|
||||||
initialised, this is not possible on the R2 device whilst a volume is
|
Metro R1 & R2 volumes must be initialised, this is not possible on the R2
|
||||||
attached.
|
device whilst a volume is attached.
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
@ -2744,17 +2955,178 @@ information on setup, configuration and usage please see the official
|
|||||||
OpenStack `volume backup`_ documentation and related `volume backup CLI`_
|
OpenStack `volume backup`_ documentation and related `volume backup CLI`_
|
||||||
guide.
|
guide.
|
||||||
|
|
||||||
|
|
||||||
|
Port group & port load balancing
|
||||||
|
--------------------------------
|
||||||
|
|
||||||
|
By default port groups are selected at random from ``cinder.conf`` when
|
||||||
|
connections are initialised between volumes on the backend array and
|
||||||
|
compute instances in Nova. If a port group is set in the volume type extra
|
||||||
|
specifications this will take precedence over any port groups configured in
|
||||||
|
``cinder.conf``. Port selection within the chosen port group is also selected
|
||||||
|
at random by default.
|
||||||
|
|
||||||
|
With port group and port load balancing in the PowerMax for Cinder driver users
|
||||||
|
can now select the port group and port load by determining which has the lowest
|
||||||
|
load. The load metric is defined by the user in both instances so the selection
|
||||||
|
process can better match the needs of the user and their environment. Available
|
||||||
|
metrics are detailed in the ``performance metrics`` section.
|
||||||
|
|
||||||
|
Port Groups are reported on at five minute time deltas (diagnostic), and FE
|
||||||
|
Ports are reported on at one minute time deltas (real-time) if real-time
|
||||||
|
metrics are enabled, else default five minute time delta (diagnostic). The
|
||||||
|
window at which performance metrics are analysed is a user-configured option in
|
||||||
|
``cinder.conf``, this is detailed in the ``configuration`` section.
|
||||||
|
|
||||||
|
Calculating load
|
||||||
|
~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
The process by which Port Group or Port load is calculated is the same for
|
||||||
|
both. The user specifies the look back window which determines how many
|
||||||
|
performance intervals to measure, 60 minutes will give 12 intervals of 5
|
||||||
|
minutes each for example. If no lookback window is specified or is set to
|
||||||
|
0 only the most recent performance metric will be analysed. This will give a
|
||||||
|
slight performance improvement but with the improvements made to the
|
||||||
|
performance REST endpoints for load this improvement is negligible.
|
||||||
|
For real-time stats a minimum of 1 minute is required.
|
||||||
|
|
||||||
|
Once a call is made to the performance REST endpoints, the performance data for
|
||||||
|
that PG or port is extracted. Then the metric values are summed and divided by
|
||||||
|
the count of intervals to get the average for the look back window.
|
||||||
|
|
||||||
|
The performance metric average value for each asset is added to a Python heap.
|
||||||
|
Once all assets have been measured the lowest value will always be at position
|
||||||
|
0 in the heap so there is no extra time penalty requirement for search.
|
||||||
|
|
||||||
|
|
||||||
|
Pre-requisites
|
||||||
|
~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
Before load balancing can be enabled in the PowerMax for Cinder driver
|
||||||
|
performance metrics collection must be enabled in Unisphere. Real-time
|
||||||
|
performance metrics collection is enabled separately from diagnostic metrics
|
||||||
|
collection. Performance metric collection is only available for local arrays
|
||||||
|
in Unisphere.
|
||||||
|
|
||||||
|
After performance metrics registration there is a time delay before Unisphere
|
||||||
|
records performance metrics, adequate time must be given before enabling load
|
||||||
|
balancing in Cinder else default random selection method will be used. It is
|
||||||
|
recommended to wait 4 hours after performance registration before enabling
|
||||||
|
load balancing in Cinder.
|
||||||
|
|
||||||
|
|
||||||
|
Configuration
|
||||||
|
~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
A number of configuration options are available for users so load balancing
|
||||||
|
can be set to better suit the needs of the environment. These configuration
|
||||||
|
options are detailed in the table below.
|
||||||
|
|
||||||
|
.. table:: Load balance cinder.conf configuration options
|
||||||
|
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
| ``cinder.conf parameter`` | options | Default | Description |
|
||||||
|
+=============================+================+=================+========================================+
|
||||||
|
| ``load_balance`` | ``True/False`` | ``False`` | | Enable/disable load balancing for |
|
||||||
|
| | | | | a PowerMax backend. |
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
| ``load_balance_real_time`` | ``True/False`` | ``False`` | | Enable/disable real-time performance |
|
||||||
|
| | | | | metrics for Port level metrics |
|
||||||
|
| | | | | (not available for Port Group). |
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
| ``load_data_format`` | ``Avg/Max`` | ``Avg`` | | Performance data format, not |
|
||||||
|
| | | | | applicable for real-time. |
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
| ``load_lookback`` | ``int`` | ``60`` | | How far in minutes to look back for |
|
||||||
|
| | | | | diagnostic performance metrics in |
|
||||||
|
| | | | | load calculation, minimum of 0 |
|
||||||
|
| | | | | maximum of 1440 (24 hours). |
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
| ``load_real_time_lookback`` | ``int`` | ``1`` | | How far in minutes to look back for |
|
||||||
|
| | | | | real-time performance metrics in |
|
||||||
|
| | | | | load calculation, minimum of 1 |
|
||||||
|
| | | | | maximum of 60 (24 hours). |
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
| ``port_group_load_metric`` | See below | ``PercentBusy`` | | Metric used for port group load |
|
||||||
|
| | | | | calculation. |
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
| ``port_load_metric`` | See below | ``PercentBusy`` | | Metric used for port group load |
|
||||||
|
| | | | | calculation. |
|
||||||
|
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||||||
|
|
||||||
|
Port-Group Metrics
|
||||||
|
~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
.. table:: Port-group performance metrics
|
||||||
|
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| Metric | cinder.conf option | Description |
|
||||||
|
+===================+====================+===========================================================+
|
||||||
|
| % Busy | ``PercentBusy`` | The percent of time the port group is busy. |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| Avg IO Size (KB) | ``AvgIOSize`` | | Calculated value: (HA Kbytes transferred per sec / |
|
||||||
|
| | | | total IOs per sec) |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| Host IOs/sec | ``IOs`` | | The number of host IO operations performed each second, |
|
||||||
|
| | | | including writes and random and sequential reads. |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| Host MBs/sec | ``MBs`` | The number of host MBs read each second. |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| MBs Read/sec | ``MBRead`` | The number of reads per second in MBs. |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| MBs Written/sec | ``MBWritten`` | The number of writes per second in MBs. |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| Reads/sec | ``Reads`` | The average number of host reads performed per second. |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
| Writes/sec | ``Writes`` | The average number of host writes performed per second. |
|
||||||
|
+-------------------+--------------------+-----------------------------------------------------------+
|
||||||
|
|
||||||
|
Port Metrics
|
||||||
|
~~~~~~~~~~~~
|
||||||
|
|
||||||
|
.. table:: Port performance metrics
|
||||||
|
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Metric | cinder.conf option | Real-Time Supported | Description |
|
||||||
|
+=====================+=======================+=====================+============================================================+
|
||||||
|
| % Busy | ``PercentBusy`` | Yes | The percent of time the port is busy. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Avg IO Size (KB) | ``AvgIOSize`` | Yes | | Calculated value: (HA Kbytes transferred per sec / |
|
||||||
|
| | | | | total IOs per sec) |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Host IOs/sec | ``IOs`` | Yes | | The number of host IO operations performed each second, |
|
||||||
|
| | | | | including writes and random and sequential reads. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Host MBs/sec | ``MBs`` | Yes | The number of host MBs read each second. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| MBs Read/sec | ``MBRead`` | Yes | The number of reads per second in MBs. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| MBs Written/sec | ``MBWritten`` | Yes | The number of writes per second in MBs. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Reads/sec | ``Reads`` | Yes | The number of read operations performed by the port per |
|
||||||
|
| | | | second. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Writes/sec | ``Writes`` | Yes | The number of write operations performed each second by |
|
||||||
|
| | | | the port. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Speed Gb/sec | ``SpeedGBs`` | No | Speed. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Response Time (ms) | ``ResponseTime`` | No | The average response time for the reads and writes. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Read RT (ms) | ``ReadResponseTime`` | No | The average time it takes to serve one read IO. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
| Write RT (ms) | ``WriteResponseTime`` | No | The average time it takes to serve one write IO. |
|
||||||
|
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||||||
|
|
||||||
|
|
||||||
Upgrading from SMI-S based driver to REST API based driver
|
Upgrading from SMI-S based driver to REST API based driver
|
||||||
==========================================================
|
==========================================================
|
||||||
|
|
||||||
Seamless upgrades from an SMI-S based driver to REST API based driver,
|
Seamless upgrades from an SMI-S based driver to REST API based driver,
|
||||||
following the setup instructions above, are supported with a few exceptions:
|
following the setup instructions above, are supported with a few exceptions:
|
||||||
|
|
||||||
#. OpenStack's ``live migration`` functionality will not work on already
|
#. Seamless upgrade from SMI-S(Ocata and earlier) to REST(Pike and later)
|
||||||
attached/in-use legacy volumes without first migrating the volumes to
|
is now available on all functionality including Live Migration.
|
||||||
the new REST masking view structure. If you are upgrading from Newton
|
|
||||||
or Ocata to Pike or greater please contact `Dell EMC Support`_ and we
|
|
||||||
will guide you through the process.
|
|
||||||
|
|
||||||
#. Consistency groups are deprecated in Pike. Generic Volume Groups are
|
#. Consistency groups are deprecated in Pike. Generic Volume Groups are
|
||||||
supported from Pike onwards.
|
supported from Pike onwards.
|
||||||
|