ScaleIO: Rebranding of product to VxFlex OS
The Dell EMC ScaleIO product is being renamed to Dell EMC VxFlex OS. Update the documentation to reflect the new product name. Change-Id: Ib52e4820c80db8b2a74bd91dce473182508c7fba
This commit is contained in:
parent
1f76e2cd7d
commit
a852c46ba4
@ -57,7 +57,7 @@ LOG = logging.getLogger(__name__)
|
||||
scaleio_opts = [
|
||||
cfg.StrOpt('sio_rest_server_port',
|
||||
default='443',
|
||||
help='REST server port.'),
|
||||
help='Gateway REST server port.'),
|
||||
cfg.BoolOpt('sio_verify_server_certificate',
|
||||
default=False,
|
||||
help='Verify server certificate.'),
|
||||
@ -65,12 +65,18 @@ scaleio_opts = [
|
||||
help='Server certificate path.'),
|
||||
cfg.BoolOpt('sio_round_volume_capacity',
|
||||
default=True,
|
||||
help='Round up volume capacity.'),
|
||||
help='Round volume sizes up to 8GB boundaries. '
|
||||
'VxFlex OS/ScaleIO requires volumes to be sized '
|
||||
'in multiples of 8GB. If set to False, volume '
|
||||
'creation will fail for volumes not sized properly'),
|
||||
cfg.BoolOpt('sio_unmap_volume_before_deletion',
|
||||
default=False,
|
||||
help='Unmap volume before deletion.'),
|
||||
help='Unmap volumes before deletion.'),
|
||||
cfg.StrOpt('sio_storage_pools',
|
||||
help='Storage Pools.'),
|
||||
help='Storage Pools. Comma separated list of storage '
|
||||
'pools used to provide volumes. Each pool should '
|
||||
'be specified as a '
|
||||
'protection_domain_name:storage_pool_name value'),
|
||||
cfg.StrOpt('sio_protection_domain_id',
|
||||
deprecated_for_removal=True,
|
||||
deprecated_reason="Replaced by sio_storage_pools option",
|
||||
@ -92,16 +98,15 @@ scaleio_opts = [
|
||||
deprecated_since="Pike",
|
||||
help='DEPRECATED: Storage Pool ID.'),
|
||||
cfg.StrOpt('sio_server_api_version',
|
||||
help='ScaleIO API version.'),
|
||||
help='VxFlex OS/ScaleIO API version. This value should be '
|
||||
'left as the default value unless otherwise instructed '
|
||||
'by technical support.'),
|
||||
cfg.FloatOpt('sio_max_over_subscription_ratio',
|
||||
# This option exists to provide a default value for the
|
||||
# ScaleIO driver which is different than the global default.
|
||||
default=10.0,
|
||||
help='max_over_subscription_ratio setting for the ScaleIO '
|
||||
'driver. This replaces the general '
|
||||
'max_over_subscription_ratio which has no effect '
|
||||
'in this driver.'
|
||||
'Maximum value allowed for ScaleIO is 10.0.'),
|
||||
help='max_over_subscription_ratio setting for the driver. '
|
||||
'Maximum value allowed is 10.0.'),
|
||||
cfg.BoolOpt('sio_allow_non_padded_thick_volumes',
|
||||
default=False,
|
||||
help='Allow thick volumes to be created in Storage Pools '
|
||||
|
@ -1,53 +1,62 @@
|
||||
=====================================
|
||||
Dell EMC ScaleIO Block Storage driver
|
||||
=====================================
|
||||
===========================================
|
||||
Dell EMC VxFlex OS (ScaleIO) Storage driver
|
||||
===========================================
|
||||
|
||||
Overview
|
||||
--------
|
||||
|
||||
ScaleIO is a software-only solution that uses existing servers' local
|
||||
Dell EMC VxFlex OS (formerly named Dell EMC ScaleIO) is a software-only
|
||||
solution that uses existing servers local
|
||||
disks and LAN to create a virtual SAN that has all of the benefits of
|
||||
external storage, but at a fraction of the cost and complexity. Using the
|
||||
driver, Block Storage hosts can connect to a ScaleIO Storage
|
||||
driver, Block Storage hosts can connect to a VxFlex OS Storage
|
||||
cluster.
|
||||
|
||||
.. _scale_io_docs:
|
||||
The Dell EMC VxFlex OS Cinder driver is designed and tested to work with
|
||||
both VxFlex OS and with ScaleIO. The
|
||||
:ref:`configuration options <cg_configuration_options_emc>`
|
||||
are identical for both VxFlex OS and ScaleIO.
|
||||
|
||||
Official ScaleIO documentation
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
.. _scaleio_docs:
|
||||
|
||||
To find the ScaleIO documentation:
|
||||
Official VxFlex OS documentation
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
#. Go to the `ScaleIO product documentation page <https://support.emc.com/products/33925_ScaleIO/Documentation/?source=promotion>`_.
|
||||
To find the VxFlex OS documentation:
|
||||
|
||||
#. From the left-side panel, select the relevant ScaleIO version.
|
||||
#. Go to the `VxFlex OS product documentation page <https://support.emc.com/products/33925_ScaleIO/Documentation/?source=promotion>`_.
|
||||
|
||||
Supported ScaleIO Versions
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
#. From the left-side panel, select the relevant VxFlex OS version.
|
||||
|
||||
The Dell EMC ScaleIO Block Storage driver has been tested against the
|
||||
following versions of ScaleIO and found to be compatible:
|
||||
Supported VxFlex OS and ScaleIO Versions
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The Dell EMC VxFlex OS Block Storage driver has been tested against the
|
||||
following versions of ScaleIO and VxFlex OS and found to be compatible:
|
||||
|
||||
* ScaleIO 2.0.x
|
||||
* ScaleIO 2.5.x
|
||||
* VxFlex OS 2.6.x
|
||||
|
||||
Please consult the :ref:`scale_io_docs`
|
||||
to determine supported operating systems for each version of ScaleIO.
|
||||
Please consult the :ref:`scaleio_docs`
|
||||
to determine supported operating systems for each version
|
||||
of VxFlex OS or ScaleIO.
|
||||
|
||||
Deployment prerequisites
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
* ScaleIO Gateway must be installed and accessible in the network.
|
||||
* The VxFlex OS Gateway must be installed and accessible in the network.
|
||||
For installation steps, refer to the Preparing the installation Manager
|
||||
and the Gateway section in ScaleIO Deployment Guide. See
|
||||
:ref:`scale_io_docs`.
|
||||
and the Gateway section in VxFlex OS Deployment Guide. See
|
||||
:ref:`scaleio_docs`.
|
||||
|
||||
* ScaleIO Data Client (SDC) must be installed on all OpenStack nodes.
|
||||
* VxFlex OS Storage Data Client (SDC) must be installed
|
||||
on all OpenStack nodes.
|
||||
|
||||
.. note:: Ubuntu users must follow the specific instructions in the ScaleIO
|
||||
Deployment Guide for Ubuntu environments. See the ``Deploying on
|
||||
Ubuntu Servers`` section in ScaleIO Deployment Guide. See
|
||||
:ref:`scale_io_docs`.
|
||||
.. note:: Ubuntu users must follow the specific instructions in the VxFlex
|
||||
OS Deployment Guide for Ubuntu environments. See the ``Deploying
|
||||
on Ubuntu Servers`` section in VxFlex OS Deployment Guide. See
|
||||
:ref:`scaleio_docs`.
|
||||
|
||||
Supported operations
|
||||
~~~~~~~~~~~~~~~~~~~~
|
||||
@ -71,11 +80,11 @@ Supported operations
|
||||
* Create, list, update, and delete consistency group snapshots
|
||||
|
||||
|
||||
ScaleIO Block Storage driver configuration
|
||||
------------------------------------------
|
||||
VxFlex OS Block Storage driver configuration
|
||||
--------------------------------------------
|
||||
|
||||
This section explains how to configure and connect the block storage
|
||||
nodes to a ScaleIO storage cluster.
|
||||
nodes to a VxFlex OS storage cluster.
|
||||
|
||||
Edit the ``cinder.conf`` file by adding the configuration below under
|
||||
a new section (for example, ``[scaleio]``) and change the ``enable_backends``
|
||||
@ -86,8 +95,8 @@ The configuration file is usually located at
|
||||
For a configuration example, refer to the example
|
||||
:ref:`cinder.conf <cg_configuration_example_emc>` .
|
||||
|
||||
ScaleIO driver name
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
VxFlex OS driver name
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Configure the driver name by adding the following parameter:
|
||||
|
||||
@ -95,19 +104,19 @@ Configure the driver name by adding the following parameter:
|
||||
|
||||
volume_driver = cinder.volume.drivers.dell_emc.scaleio.driver.ScaleIODriver
|
||||
|
||||
ScaleIO Gateway server IP
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
VxFlex OS Gateway server IP
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The ScaleIO Gateway provides a REST interface to ScaleIO.
|
||||
The VxFlex OS Gateway provides a REST interface to VxFlex OS.
|
||||
|
||||
Configure the Gateway server IP address by adding the following parameter:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
san_ip = <ScaleIO GATEWAY IP>
|
||||
san_ip = <VxFlex OS GATEWAY IP>
|
||||
|
||||
ScaleIO Storage Pools
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
VxFlex OS Storage Pools
|
||||
~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Multiple Storage Pools and Protection Domains can be listed for use by
|
||||
the virtual machines. The list should include every Protection Domain and
|
||||
@ -122,14 +131,14 @@ Configure the available Storage Pools by adding the following parameter:
|
||||
|
||||
sio_storage_pools = <Comma-separated list of protection domain:storage pool name>
|
||||
|
||||
ScaleIO user credentials
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
VxFlex OS user credentials
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Block Storage requires a ScaleIO user with administrative
|
||||
privileges. ScaleIO recommends creating a dedicated OpenStack user
|
||||
Block Storage requires a VxFlex OS user with administrative
|
||||
privileges. Dell EMC recommends creating a dedicated OpenStack user
|
||||
account that has an administrative user role.
|
||||
|
||||
Refer to the ScaleIO User Guide for details on user account management.
|
||||
Refer to the VxFlex OS User Guide for details on user account management.
|
||||
|
||||
Configure the user credentials by adding the following parameters:
|
||||
|
||||
@ -142,7 +151,7 @@ Oversubscription
|
||||
~~~~~~~~~~~~~~~~
|
||||
|
||||
Configure the oversubscription ratio by adding the following parameter
|
||||
under the separate section for ScaleIO:
|
||||
under the separate section for VxFlex OS:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
@ -156,7 +165,7 @@ under the separate section for ScaleIO:
|
||||
Oversubscription is calculated correctly by the Block Storage service
|
||||
only if the extra specification ``provisioning:type``
|
||||
appears in the volume type regardless of the default provisioning type.
|
||||
Maximum oversubscription value supported for ScaleIO is 10.0.
|
||||
Maximum oversubscription value supported for VxFlex OS is 10.0.
|
||||
|
||||
Default provisioning type
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
@ -202,10 +211,12 @@ parameters as follows:
|
||||
san_password = SIO_PASSWD
|
||||
san_thin_provision = false
|
||||
|
||||
.. _cg_configuration_options_emc:
|
||||
|
||||
Configuration options
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The ScaleIO driver supports these configuration options:
|
||||
The VxFlex OS driver supports these configuration options:
|
||||
|
||||
.. config-table::
|
||||
:config-target: ScaleIO
|
||||
@ -216,11 +227,11 @@ Volume Types
|
||||
------------
|
||||
|
||||
Volume types can be used to specify characteristics of volumes allocated via the
|
||||
ScaleIO Driver. These characteristics are defined as ``Extra Specs`` within
|
||||
VxFlex OS Driver. These characteristics are defined as ``Extra Specs`` within
|
||||
``Volume Types``.
|
||||
|
||||
ScaleIO Protection Domain and Storage Pool
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
VxFlex OS Protection Domain and Storage Pool
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
When multiple storage pools are specified in the Cinder configuration,
|
||||
users can specify which pool should be utilized by adding the ``pool``
|
||||
@ -233,8 +244,8 @@ requested protection_domain:storage_pool.
|
||||
$ openstack volume type set --property volume_backend_name=scaleio sio_type_1
|
||||
$ openstack volume type set --property pool=Domain2:Pool2 sio_type_1
|
||||
|
||||
ScaleIO thin provisioning support
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
VxFlex OS thin provisioning support
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The Block Storage driver supports creation of thin-provisioned and
|
||||
thick-provisioned volumes.
|
||||
@ -246,10 +257,10 @@ of the volume type, as follows:
|
||||
$ openstack volume type create sio_type_thick
|
||||
$ openstack volume type set --property provisioning:type=thick sio_type_thick
|
||||
|
||||
ScaleIO QoS support
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
VxFlex OS QoS support
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
QoS support for the ScaleIO driver includes the ability to set the
|
||||
QoS support for the VxFlex OS driver includes the ability to set the
|
||||
following capabilities:
|
||||
|
||||
``maxIOPS``
|
||||
@ -287,8 +298,8 @@ and the relevant calculated value of ``maxIOPSperGB`` or ``maxBWSperGB``.
|
||||
Since the limits are per SDC, they will be applied after the volume
|
||||
is attached to an instance, and thus to a compute node/SDC.
|
||||
|
||||
Using ScaleIO Storage with a containerized overcloud
|
||||
----------------------------------------------------
|
||||
Using VxFlex OS Storage with a containerized overcloud
|
||||
------------------------------------------------------
|
||||
|
||||
When using a containerized overcloud, such as one deployed via TripleO or RedHat
|
||||
Openstack version 12 and above, there is an additional step that must be
|
||||
@ -297,7 +308,7 @@ performed.
|
||||
Before deploying the overcloud
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
After ensuring that the ScaleIO Data Client (SDC) is installed on all nodes and
|
||||
After ensuring that the Storage Data Client (SDC) is installed on all nodes and
|
||||
before deploying the overcloud,
|
||||
modify the TripleO Heat Template for the nova-compute and cinder-volume
|
||||
containers to add volume mappings for directories containing the SDC
|
@ -35,11 +35,11 @@ Driver Configuration Reference
|
||||
drivers/datacore-volume-driver
|
||||
drivers/datera-volume-driver
|
||||
drivers/dell-equallogic-driver
|
||||
drivers/dell-emc-scaleio-driver
|
||||
drivers/dell-storagecenter-driver
|
||||
drivers/dell-emc-unity-driver
|
||||
drivers/dell-emc-vnx-driver
|
||||
drivers/dell-emc-vmax-driver
|
||||
drivers/dell-emc-vxflex-driver
|
||||
drivers/emc-xtremio-driver
|
||||
drivers/fujitsu-eternus-dx-driver
|
||||
drivers/hpe-3par-driver
|
||||
|
@ -0,0 +1,8 @@
|
||||
---
|
||||
features:
|
||||
- |
|
||||
Dell EMC ScaleIO has been renamed to Dell EMC VxFlex OS.
|
||||
Documentation for the driver can be found under the new name.
|
||||
The driver maintains full backwards compatability with prior
|
||||
ScaleIO releases and no configuration changes are needed upon
|
||||
upgrade to the new version of the driver.
|
Loading…
Reference in New Issue