cinder/releasenotes/notes/hpe-3par-use-vlan-iscsi-ips-f75787b0d281030b.yaml
raghavendrat 4482ec892f HPE 3PAR: use vlan iscsi ips
In the code hpe_3par_iscsi.py, only the trunk ips
(192.168.68.203) are considered. If vlan ips (192.168.100.1)
are specified, they aren't considered while forming list of
iscsi ips.

Sample output of "showport" command from HPE 3par storage system:

CSSOS-SSA04 cli% showport -iscsivlans
N:S:P VLAN IPAddr        Netmask
0:2:1  -  192.168.68.203 255.255.192.0
0:2:1 100 192.168.100.1  255.255.192.0
0:2:1 200 192.168.100.2  255.255.255.0

Kindly refer launchpad bug for details.

This patch adds support for using vlan iscsi ips.

Closes-Bug: #2015034
Change-Id: Idaea18411ae03c5a9696b2ab67e84087177fcc74
2023-06-23 07:11:41 +00:00

6 lines
164 B
YAML

fixes:
- |
HPE 3PAR driver `Bug #2015034 <https://bugs.launchpad.net/cinder/+bug/2015034>`_:
Added handling for VLAN iscsi IPs in the 3PAR iSCSI driver.