Inspector Support

Ironic supports in-band inspection using the ironic-inspector project. This is the original in-band inspection implementation, which is being gradually phased out in favour of a similar implementation inside Ironic proper.

It is supported by all hardware types, and used by default, if enabled, by the ipmi hardware type. The inspector inspect interface has to be enabled to use it:

[DEFAULT]
enabled_inspect_interfaces = inspector,no-inspect

If the ironic-inspector service is not registered in the service catalog, set the following option:

[inspector]
endpoint_override = http://inspector.example.com:5050

In order to ensure that ports in Bare Metal service are synchronized with NIC ports on the node, the following settings in the ironic-inspector configuration file must be set:

[processing]
add_ports = all
keep_ports = present

There are two modes of in-band inspection: managed inspection and unmanaged inspection.

Managed inspection

Inspection is managed when the Bare Metal conductor fully configures the node for inspection, including setting boot device, boot mode and power state. This is the only way to conduct inspection using redfish-virtual-media or with /admin/dhcp-less. This mode is engaged automatically when the node has sufficient information to configure boot (e.g. ports in case of iPXE).

There are a few configuration options that tune managed inspection, the most important is extra_kernel_params, which allows adding kernel parameters for inspection specifically. This is where you can configure inspection collectors and other parameters <admin/how_it_works.html#inspection>, for example:

[inspector]
extra_kernel_params = ipa-inspection-collectors=default,logs ipa-collect-lldp=1

For the callback URL the ironic-inspector endpoint from the service catalog is used. If you want to override the endpoint for callback only, set the following option:

[inspector]
callback_endpoint_override = https://example.com/baremetal-introspection/v1/continue

Unmanaged inspection

Under unmanaged inspection we understand in-band inspection orchestrated by ironic-inspector or a third party. This was the only inspection mode before the Ussuri release, and it is still used when the node's boot cannot be configured by the conductor. The options described above do not affect unmanaged inspection. See ironic-inspector installation guide <install/index.html> for more information.

If you want to prevent unmanaged inspection from working, set this option:

[inspector]
require_managed_boot = True