SNMP driver
===========
The SNMP power driver enables control of power distribution units of the type
frequently found in data centre racks. PDUs frequently have a management
ethernet interface and SNMP support enabling control of the power outlets.
The SNMP power driver works with the PXE driver for network deployment and
network-configured boot.
List of supported devices
=========================
This is a non-exhaustive list of supported devices. Any device not listed in
this table could possibly work using a similar driver.
Please report any device status.
============== ========== ========== =====================
Manufacturer Model Supported? Driver name
============== ========== ========== =====================
APC AP7920 Yes apc_masterswitch
APC AP9606 Yes apc_masterswitch
APC AP9225 Yes apc_masterswitchplus
APC AP7155 Yes apc_rackpdu
APC AP7900 Yes apc_rackpdu
APC AP7901 Yes apc_rackpdu
APC AP7902 Yes apc_rackpdu
APC AP7911a Yes apc_rackpdu
APC AP7930 Yes apc_rackpdu
APC AP7931 Yes apc_rackpdu
APC AP7932 Yes apc_rackpdu
APC AP7940 Yes apc_rackpdu
APC AP7941 Yes apc_rackpdu
APC AP7951 Yes apc_rackpdu
APC AP7960 Yes apc_rackpdu
APC AP7990 Yes apc_rackpdu
APC AP7998 Yes apc_rackpdu
APC AP8941 Yes apc_rackpdu
APC AP8953 Yes apc_rackpdu
APC AP8959 Yes apc_rackpdu
APC AP8961 Yes apc_rackpdu
APC AP8965 Yes apc_rackpdu
Aten all? Yes aten
CyberPower all? Untested cyberpower
EatonPower all? Untested eatonpower
Teltronix all? Yes teltronix
============== ========== ========== =====================
Software Requirements
=====================
- The PySNMP package must be installed, variously referred to as ``pysnmp``
or ``python-pysnmp``
Enabling the SNMP Power Driver
==============================
- Add ``pxe_snmp`` to the list of ``enabled_drivers`` in
``/etc/ironic/ironic.conf``
- Ironic Conductor must be restarted for the new driver to be loaded.
Ironic Node Configuration
=========================
Nodes are configured for SNMP control by setting the Ironic node object's
``driver`` property to be ``pxe_snmp``. Further configuration values are
added to ``driver_info``:
- ``snmp_driver``: PDU manufacturer driver
- ``snmp_address``: the IPv4 address of the PDU controlling this node.
- ``snmp_port``: (optional) A non-standard UDP port to use for SNMP operations.
If not specified, the default port (161) is used.
- ``snmp_outlet``: The power outlet on the PDU (1-based indexing).
- ``snmp_protocol``: (optional) SNMP protocol version
(permitted values ``1``, ``2c`` or ``3``). If not specified, SNMPv1
is chosen.
- ``snmp_community``: (Required for SNMPv1 and SNMPv2c) SNMP community
parameter for reads and writes to the PDU.
- ``snmp_security``: (Required for SNMPv3) SNMP security string.
PDU Configuration
=================
This version of the SNMP power driver does not support handling
PDU authentication credentials. When using SNMPv3, the PDU must be
configured for ``NoAuthentication`` and ``NoEncryption``. The
security name is used analogously to the SNMP community in early
SNMP versions.