Provide 3 new snmp_driver values for different APC product families: - apc_masterswitch - apc_masterswitchplus - apc_rackpdu The "apc" snmp_driver is still supported and maps to the MasterSwitch driver to avoid breaking backwards compatibility. Different APC product families support different OIDs for power control. - APC MasterSwitch uses sPDUOutletCtl - APC MasterSwitchPlus uses sPDUOutletControlMSPOutletCommand - APC Rack PDU uses rPDUOutletControlOutletCommand Change-Id: I9d8724543d7da7b1c9cdc180c3396d131ed52615 Closes-Bug: #1471025
92 lines
3.8 KiB
ReStructuredText
92 lines
3.8 KiB
ReStructuredText
===========
|
|
SNMP driver
|
|
===========
|
|
|
|
The SNMP power driver enables control of power distribution units of the type
|
|
frequently found in data centre racks. PDUs frequently have a management
|
|
ethernet interface and SNMP support enabling control of the power outlets.
|
|
|
|
The SNMP power driver works with the PXE driver for network deployment and
|
|
network-configured boot.
|
|
|
|
List of supported devices
|
|
=========================
|
|
|
|
This is a non-exhaustive list of supported devices. Any device not listed in
|
|
this table could possibly work using a similar driver.
|
|
|
|
Please report any device status.
|
|
|
|
============== ========== ========== =====================
|
|
Manufacturer Model Supported? Driver name
|
|
============== ========== ========== =====================
|
|
APC AP7920 Yes apc_masterswitch
|
|
APC AP9606 Yes apc_masterswitch
|
|
APC AP9225 Yes apc_masterswitchplus
|
|
APC AP7155 Yes apc_rackpdu
|
|
APC AP7900 Yes apc_rackpdu
|
|
APC AP7901 Yes apc_rackpdu
|
|
APC AP7902 Yes apc_rackpdu
|
|
APC AP7911a Yes apc_rackpdu
|
|
APC AP7930 Yes apc_rackpdu
|
|
APC AP7931 Yes apc_rackpdu
|
|
APC AP7932 Yes apc_rackpdu
|
|
APC AP7940 Yes apc_rackpdu
|
|
APC AP7941 Yes apc_rackpdu
|
|
APC AP7951 Yes apc_rackpdu
|
|
APC AP7960 Yes apc_rackpdu
|
|
APC AP7990 Yes apc_rackpdu
|
|
APC AP7998 Yes apc_rackpdu
|
|
APC AP8941 Yes apc_rackpdu
|
|
APC AP8953 Yes apc_rackpdu
|
|
APC AP8959 Yes apc_rackpdu
|
|
APC AP8961 Yes apc_rackpdu
|
|
APC AP8965 Yes apc_rackpdu
|
|
Aten all? Yes aten
|
|
CyberPower all? Untested cyberpower
|
|
EatonPower all? Untested eatonpower
|
|
Teltronix all? Yes teltronix
|
|
============== ========== ========== =====================
|
|
|
|
|
|
Software Requirements
|
|
=====================
|
|
|
|
- The PySNMP package must be installed, variously referred to as ``pysnmp``
|
|
or ``python-pysnmp``
|
|
|
|
Enabling the SNMP Power Driver
|
|
==============================
|
|
|
|
- Add ``pxe_snmp`` to the list of ``enabled_drivers`` in
|
|
``/etc/ironic/ironic.conf``
|
|
- Ironic Conductor must be restarted for the new driver to be loaded.
|
|
|
|
Ironic Node Configuration
|
|
=========================
|
|
|
|
Nodes are configured for SNMP control by setting the Ironic node object's
|
|
``driver`` property to be ``pxe_snmp``. Further configuration values are
|
|
added to ``driver_info``:
|
|
|
|
- ``snmp_driver``: PDU manufacturer driver
|
|
- ``snmp_address``: the IPv4 address of the PDU controlling this node.
|
|
- ``snmp_port``: (optional) A non-standard UDP port to use for SNMP operations.
|
|
If not specified, the default port (161) is used.
|
|
- ``snmp_outlet``: The power outlet on the PDU (1-based indexing).
|
|
- ``snmp_protocol``: (optional) SNMP protocol version
|
|
(permitted values ``1``, ``2c`` or ``3``). If not specified, SNMPv1
|
|
is chosen.
|
|
- ``snmp_community``: (Required for SNMPv1 and SNMPv2c) SNMP community
|
|
parameter for reads and writes to the PDU.
|
|
- ``snmp_security``: (Required for SNMPv3) SNMP security string.
|
|
|
|
PDU Configuration
|
|
=================
|
|
|
|
This version of the SNMP power driver does not support handling
|
|
PDU authentication credentials. When using SNMPv3, the PDU must be
|
|
configured for ``NoAuthentication`` and ``NoEncryption``. The
|
|
security name is used analogously to the SNMP community in early
|
|
SNMP versions.
|