Configuring IPMI support
Installing ipmitool command
To enable one of the drivers that use IPMI
protocol for power and management actions (for example,
ipmi
, pxe_ipmitool
and
agent_ipmitool
), the ipmitool
command must be
present on the service node(s) where ironic-conductor
is
running. On most distros, it is provided as part of the
ipmitool
package. Source code is available at http://ipmitool.sourceforge.net/.
Warning
Certain distros, notably Mac OS X and SLES, install
openipmi
instead of ipmitool
by default. This
driver is not compatible with openipmi
as it relies on
error handling options not provided by this tool.
Please refer to the ipmitool driver page for information on how to use IPMItool-based drivers.
Validation and troubleshooting
Check that you can connect to, and authenticate with, the IPMI
controller in your bare metal server by running
ipmitool
:
ipmitool -I lanplus -H <ip-address> -U <username> -P <password> chassis power status
where <ip-address>
is the IP of the IPMI
controller you want to access. This is not the bare metal node's main
IP. The IPMI controller should have its own unique IP.
If the above command doesn't return the power status of the bare metal server, check that
ipmitool
is installed and is available via the$PATH
environment variable.- The IPMI controller on your bare metal server is turned on.
- The IPMI controller credentials and IP address passed in the command are correct.
- The conductor node has a route to the IPMI controller. This can be checked by just pinging the IPMI controller IP from the conductor node.
IPMI configuration
If there are slow or unresponsive BMCs in the environment, the
retry_timeout
configuration option in the
[ipmi]
section may need to be lowered. The default is
fairly conservative, as setting this timeout too low can cause older
BMCs to crash and require a hard-reset.
Collecting sensor data
Bare Metal service supports sending IPMI sensor data to Telemetry
with certain drivers, such as drivers ending with ipmitool
,
ilo
and irmc
. By default, support for sending
IPMI sensor data to Telemetry is disabled. If you want to enable it, you
should make the following two changes in ironic.conf
:
[DEFAULT]
notification_driver = messaging
[conductor]
send_sensor_data = true
If you want to customize the sensor types which will be sent to
Telemetry, change the send_sensor_data_types
option. For
example, the below settings will send information about temperature,
fan, voltage from sensors to the Telemetry service:
send_sensor_data_types=Temperature,Fan,Voltage
Supported sensor types are defined by the Telemetry service,
currently these are Temperature
, Fan
,
Voltage
, Current
. Special value
All
(the default) designates all supported sensor
types.