The iSCSI deploy was very easy to start with, but it has since become apparently that it suffers from scalability and maintenance issues. It was deprecated in the Victoria cycle and can now be removed. Hide the guide to upgrade to hardware types since it's very outdated. I had to remove the iBMC diagram since my SVG-fu is not enough to fix it. Change-Id: I2cd6bf7b27fe0be2c08104b0cc37654b506b2e62
865 lines
38 KiB
ReStructuredText
865 lines
38 KiB
ReStructuredText
.. _troubleshooting:
|
|
|
|
======================
|
|
Troubleshooting Ironic
|
|
======================
|
|
|
|
Nova returns "No valid host was found" Error
|
|
============================================
|
|
|
|
Sometimes Nova Conductor log file "nova-conductor.log" or a message returned
|
|
from Nova API contains the following error::
|
|
|
|
NoValidHost: No valid host was found. There are not enough hosts available.
|
|
|
|
"No valid host was found" means that the Nova Scheduler could not find a bare
|
|
metal node suitable for booting the new instance.
|
|
|
|
This in turn usually means some mismatch between resources that Nova expects
|
|
to find and resources that Ironic advertised to Nova.
|
|
|
|
A few things should be checked in this case:
|
|
|
|
#. Make sure that enough nodes are in ``available`` state, not in
|
|
maintenance mode and not already used by an existing instance.
|
|
Check with the following command::
|
|
|
|
baremetal node list --provision-state available --no-maintenance --unassociated
|
|
|
|
If this command does not show enough nodes, use generic ``baremetal
|
|
node list`` to check other nodes. For example, nodes in ``manageable`` state
|
|
should be made available::
|
|
|
|
baremetal node provide <IRONIC NODE>
|
|
|
|
The Bare metal service automatically puts a node in maintenance mode if
|
|
there are issues with accessing its management interface. Check the power
|
|
credentials (e.g. ``ipmi_address``, ``ipmi_username`` and ``ipmi_password``)
|
|
and then move the node out of maintenance mode::
|
|
|
|
baremetal node maintenance unset <IRONIC NODE>
|
|
|
|
The ``node validate`` command can be used to verify that all required fields
|
|
are present. The following command should not return anything::
|
|
|
|
baremetal node validate <IRONIC NODE> | grep -E '(power|management)\W*False'
|
|
|
|
Maintenance mode will be also set on a node if automated cleaning has
|
|
failed for it previously.
|
|
|
|
#. Make sure that you have Compute services running and enabled::
|
|
|
|
$ openstack compute service list --service nova-compute
|
|
+----+--------------+-------------+------+---------+-------+----------------------------+
|
|
| ID | Binary | Host | Zone | Status | State | Updated At |
|
|
+----+--------------+-------------+------+---------+-------+----------------------------+
|
|
| 7 | nova-compute | example.com | nova | enabled | up | 2017-09-04T13:14:03.000000 |
|
|
+----+--------------+-------------+------+---------+-------+----------------------------+
|
|
|
|
By default, a Compute service is disabled after 10 consecutive build
|
|
failures on it. This is to ensure that new build requests are not routed to
|
|
a broken Compute service. If it is the case, make sure to fix the source of
|
|
the failures, then re-enable it::
|
|
|
|
openstack compute service set --enable <COMPUTE HOST> nova-compute
|
|
|
|
#. Starting with the Pike release, check that all your nodes have the
|
|
``resource_class`` field set using the following command::
|
|
|
|
baremetal node list --fields uuid name resource_class
|
|
|
|
Then check that the flavor(s) are configured to request these resource
|
|
classes via their properties::
|
|
|
|
openstack flavor show <FLAVOR NAME> -f value -c properties
|
|
|
|
For example, if your node has resource class ``baremetal-large``, it will
|
|
be matched by a flavor with property ``resources:CUSTOM_BAREMETAL_LARGE``
|
|
set to ``1``. See :doc:`/install/configure-nova-flavors` for more
|
|
details on the correct configuration.
|
|
|
|
#. Upon scheduling, Nova will query the Placement API service for the
|
|
available resource providers (in the case of Ironic: nodes with a given
|
|
resource class). If placement does not have any allocation candidates for the
|
|
requested resource class, the request will result in a "No valid host
|
|
was found" error. It is hence sensible to check if Placement is aware of
|
|
resource providers (nodes) for the requested resource class with::
|
|
|
|
$ openstack allocation candidate list --resource CUSTOM_BAREMETAL_LARGE='1'
|
|
+---+-----------------------------+--------------------------------------+-------------------------------+
|
|
| # | allocation | resource provider | inventory used/capacity |
|
|
+---+-----------------------------+--------------------------------------+-------------------------------+
|
|
| 1 | CUSTOM_BAREMETAL_LARGE=1 | 2f7b9c69-c1df-4e40-b94e-5821a4ea0453 | CUSTOM_BAREMETAL_LARGE=0/1 |
|
|
+---+-----------------------------+--------------------------------------+-------------------------------+
|
|
|
|
For Ironic, the resource provider is the UUID of the available Ironic node.
|
|
If this command returns an empty list (or does not contain the targeted
|
|
resource provider), the operator needs to understand first, why the resource
|
|
tracker has not reported this provider to placement. Potential explanations
|
|
include:
|
|
|
|
* the resource tracker cycle has not finished yet and the resource provider
|
|
will appear once it has (the time to finish the cycle scales linearly with
|
|
the number of nodes the corresponding ``nova-compute`` service manages);
|
|
|
|
* the node is in a state where the resource tracker does not consider it to
|
|
be eligible for scheduling, e.g. when the node has ``maintenance`` set to
|
|
``True``; make sure the target nodes are in ``available`` and
|
|
``maintenance`` is ``False``;
|
|
|
|
#. If you do not use scheduling based on resource classes, then the node's
|
|
properties must have been set either manually or via inspection.
|
|
For each node with ``available`` state check that the ``properties``
|
|
JSON field has valid values for the keys ``cpus``, ``cpu_arch``,
|
|
``memory_mb`` and ``local_gb``. Example of valid properties::
|
|
|
|
$ baremetal node show <IRONIC NODE> --fields properties
|
|
+------------+------------------------------------------------------------------------------------+
|
|
| Property | Value |
|
|
+------------+------------------------------------------------------------------------------------+
|
|
| properties | {u'memory_mb': u'8192', u'cpu_arch': u'x86_64', u'local_gb': u'41', u'cpus': u'4'} |
|
|
+------------+------------------------------------------------------------------------------------+
|
|
|
|
.. warning::
|
|
If you're using exact match filters in the Nova Scheduler, make sure
|
|
the flavor and the node properties match exactly.
|
|
|
|
#. The Nova flavor that you are using does not match any properties of the
|
|
available Ironic nodes. Use
|
|
::
|
|
|
|
openstack flavor show <FLAVOR NAME>
|
|
|
|
to compare. The extra specs in your flavor starting with ``capability:``
|
|
should match ones in ``node.properties['capabilities']``.
|
|
|
|
.. note::
|
|
The format of capabilities is different in Nova and Ironic.
|
|
E.g. in Nova flavor::
|
|
|
|
$ openstack flavor show <FLAVOR NAME> -c properties
|
|
+------------+----------------------------------+
|
|
| Field | Value |
|
|
+------------+----------------------------------+
|
|
| properties | capabilities:boot_option='local' |
|
|
+------------+----------------------------------+
|
|
|
|
But in Ironic node::
|
|
|
|
$ baremetal node show <IRONIC NODE> --fields properties
|
|
+------------+-----------------------------------------+
|
|
| Property | Value |
|
|
+------------+-----------------------------------------+
|
|
| properties | {u'capabilities': u'boot_option:local'} |
|
|
+------------+-----------------------------------------+
|
|
|
|
#. After making changes to nodes in Ironic, it takes time for those changes
|
|
to propagate from Ironic to Nova. Check that
|
|
::
|
|
|
|
openstack hypervisor stats show
|
|
|
|
correctly shows total amount of resources in your system. You can also
|
|
check ``openstack hypervisor show <IRONIC NODE>`` to see the status of
|
|
individual Ironic nodes as reported to Nova.
|
|
|
|
#. Figure out which Nova Scheduler filter ruled out your nodes. Check the
|
|
``nova-scheduler`` logs for lines containing something like::
|
|
|
|
Filter ComputeCapabilitiesFilter returned 0 hosts
|
|
|
|
The name of the filter that removed the last hosts may give some hints on
|
|
what exactly was not matched. See
|
|
:nova-doc:`Nova filters documentation <filter_scheduler.html>`
|
|
for more details.
|
|
|
|
#. If none of the above helped, check Ironic conductor log carefully to see
|
|
if there are any conductor-related errors which are the root cause for
|
|
"No valid host was found". If there are any "Error in deploy of node
|
|
<IRONIC-NODE-UUID>: [Errno 28] ..." error messages in Ironic conductor
|
|
log, it means the conductor run into a special error during deployment.
|
|
So you can check the log carefully to fix or work around and then try
|
|
again.
|
|
|
|
Patching the Deploy Ramdisk
|
|
===========================
|
|
|
|
When debugging a problem with deployment and/or inspection you may want to
|
|
quickly apply a change to the ramdisk to see if it helps. Of course you can
|
|
inject your code and/or SSH keys during the ramdisk build (depends on how
|
|
exactly you've built your ramdisk). But it's also possible to quickly modify
|
|
an already built ramdisk.
|
|
|
|
Create an empty directory and unpack the ramdisk content there:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ mkdir unpack
|
|
$ cd unpack
|
|
$ gzip -dc /path/to/the/ramdisk | cpio -id
|
|
|
|
The last command will result in the whole Linux file system tree unpacked in
|
|
the current directory. Now you can modify any files you want. The actual
|
|
location of the files will depend on the way you've built the ramdisk.
|
|
|
|
.. note::
|
|
On a systemd-based system you can use the ``systemd-nspawn`` tool (from
|
|
the ``systemd-container`` package) to create a lightweight container from
|
|
the unpacked filesystem tree::
|
|
|
|
$ sudo systemd-nspawn --directory /path/to/unpacked/ramdisk/ /bin/bash
|
|
|
|
This will allow you to run commands within the filesystem, e.g. use package
|
|
manager. If the ramdisk is also systemd-based, and you have login
|
|
credentials set up, you can even boot a real ramdisk enviroment with
|
|
|
|
::
|
|
|
|
$ sudo systemd-nspawn --directory /path/to/unpacked/ramdisk/ --boot
|
|
|
|
After you've done the modifications, pack the whole content of the current
|
|
directory back::
|
|
|
|
$ find . | cpio -H newc -o | gzip -c > /path/to/the/new/ramdisk
|
|
|
|
.. note:: You don't need to modify the kernel (e.g.
|
|
``tinyipa-master.vmlinuz``), only the ramdisk part.
|
|
|
|
API Errors
|
|
==========
|
|
|
|
The `debug_tracebacks_in_api` config option may be set to return tracebacks
|
|
in the API response for all 4xx and 5xx errors.
|
|
|
|
.. _retrieve_deploy_ramdisk_logs:
|
|
|
|
Retrieving logs from the deploy ramdisk
|
|
=======================================
|
|
|
|
When troubleshooting deployments (specially in case of a deploy failure)
|
|
it's important to have access to the deploy ramdisk logs to be able to
|
|
identify the source of the problem. By default, Ironic will retrieve the
|
|
logs from the deploy ramdisk when the deployment fails and save it on the
|
|
local filesystem at ``/var/log/ironic/deploy``.
|
|
|
|
To change this behavior, operators can make the following changes to
|
|
``/etc/ironic/ironic.conf`` under the ``[agent]`` group:
|
|
|
|
* ``deploy_logs_collect``: Whether Ironic should collect the deployment
|
|
logs on deployment. Valid values for this option are:
|
|
|
|
* ``on_failure`` (**default**): Retrieve the deployment logs upon a
|
|
deployment failure.
|
|
|
|
* ``always``: Always retrieve the deployment logs, even if the
|
|
deployment succeed.
|
|
|
|
* ``never``: Disable retrieving the deployment logs.
|
|
|
|
* ``deploy_logs_storage_backend``: The name of the storage backend where
|
|
the logs will be stored. Valid values for this option are:
|
|
|
|
* ``local`` (**default**): Store the logs in the local filesystem.
|
|
|
|
* ``swift``: Store the logs in Swift.
|
|
|
|
* ``deploy_logs_local_path``: The path to the directory where the
|
|
logs should be stored, used when the ``deploy_logs_storage_backend``
|
|
is configured to ``local``. By default logs will be stored at
|
|
**/var/log/ironic/deploy**.
|
|
|
|
* ``deploy_logs_swift_container``: The name of the Swift container to
|
|
store the logs, used when the deploy_logs_storage_backend is configured to
|
|
"swift". By default **ironic_deploy_logs_container**.
|
|
|
|
* ``deploy_logs_swift_days_to_expire``: Number of days before a log object
|
|
is marked as expired in Swift. If None, the logs will be kept forever
|
|
or until manually deleted. Used when the deploy_logs_storage_backend is
|
|
configured to "swift". By default **30** days.
|
|
|
|
When the logs are collected, Ironic will store a *tar.gz* file containing
|
|
all the logs according to the ``deploy_logs_storage_backend``
|
|
configuration option. All log objects will be named with the following
|
|
pattern::
|
|
|
|
<node>[_<instance-uuid>]_<timestamp yyyy-mm-dd-hh:mm:ss>.tar.gz
|
|
|
|
.. note::
|
|
The *instance_uuid* field is not required for deploying a node when
|
|
Ironic is configured to be used in standalone mode. If present it
|
|
will be appended to the name.
|
|
|
|
|
|
Accessing the log data
|
|
----------------------
|
|
|
|
When storing in the local filesystem
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
When storing the logs in the local filesystem, the log files can
|
|
be found at the path configured in the ``deploy_logs_local_path``
|
|
configuration option. For example, to find the logs from the node
|
|
``5e9258c4-cfda-40b6-86e2-e192f523d668``:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ ls /var/log/ironic/deploy | grep 5e9258c4-cfda-40b6-86e2-e192f523d668
|
|
5e9258c4-cfda-40b6-86e2-e192f523d668_88595d8a-6725-4471-8cd5-c0f3106b6898_2016-08-08-13:52:12.tar.gz
|
|
5e9258c4-cfda-40b6-86e2-e192f523d668_db87f2c5-7a9a-48c2-9a76-604287257c1b_2016-08-08-14:07:25.tar.gz
|
|
|
|
.. note::
|
|
When saving the logs to the filesystem, operators may want to enable
|
|
some form of rotation for the logs to avoid disk space problems.
|
|
|
|
|
|
When storing in Swift
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
When using Swift, operators can associate the objects in the
|
|
container with the nodes in Ironic and search for the logs for the node
|
|
``5e9258c4-cfda-40b6-86e2-e192f523d668`` using the **prefix** parameter.
|
|
For example:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ swift list ironic_deploy_logs_container -p 5e9258c4-cfda-40b6-86e2-e192f523d668
|
|
5e9258c4-cfda-40b6-86e2-e192f523d668_88595d8a-6725-4471-8cd5-c0f3106b6898_2016-08-08-13:52:12.tar.gz
|
|
5e9258c4-cfda-40b6-86e2-e192f523d668_db87f2c5-7a9a-48c2-9a76-604287257c1b_2016-08-08-14:07:25.tar.gz
|
|
|
|
To download a specific log from Swift, do:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ swift download ironic_deploy_logs_container "5e9258c4-cfda-40b6-86e2-e192f523d668_db87f2c5-7a9a-48c2-9a76-604287257c1b_2016-08-08-14:07:25.tar.gz"
|
|
5e9258c4-cfda-40b6-86e2-e192f523d668_db87f2c5-7a9a-48c2-9a76-604287257c1b_2016-08-08-14:07:25.tar.gz [auth 0.341s, headers 0.391s, total 0.391s, 0.531 MB/s]
|
|
|
|
The contents of the log file
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The log is just a ``.tar.gz`` file that can be extracted as:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ tar xvf <file path>
|
|
|
|
|
|
The contents of the file may differ slightly depending on the distribution
|
|
that the deploy ramdisk is using:
|
|
|
|
* For distributions using ``systemd`` there will be a file called
|
|
**journal** which contains all the system logs collected via the
|
|
``journalctl`` command.
|
|
|
|
* For other distributions, the ramdisk will collect all the contents of
|
|
the ``/var/log`` directory.
|
|
|
|
For all distributions, the log file will also contain the output of
|
|
the following commands (if present): ``ps``, ``df``, ``ip addr`` and
|
|
``iptables``.
|
|
|
|
Here's one example when extracting the content of a log file for a
|
|
distribution that uses ``systemd``:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ tar xvf 5e9258c4-cfda-40b6-86e2-e192f523d668_88595d8a-6725-4471-8cd5-c0f3106b6898_2016-08-08-13:52:12.tar.gz
|
|
df
|
|
ps
|
|
journal
|
|
ip_addr
|
|
iptables
|
|
|
|
.. _troubleshooting-stp:
|
|
|
|
DHCP during PXE or iPXE is inconsistent or unreliable
|
|
=====================================================
|
|
|
|
This can be caused by the spanning tree protocol delay on some switches. The
|
|
delay prevents the switch port moving to forwarding mode during the nodes
|
|
attempts to PXE, so the packets never make it to the DHCP server. To resolve
|
|
this issue you should set the switch port that connects to your baremetal nodes
|
|
as an edge or PortFast type port. Configured in this way the switch port will
|
|
move to forwarding mode as soon as the link is established. An example on how to
|
|
do that for a Cisco Nexus switch is:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ config terminal
|
|
$ (config) interface eth1/11
|
|
$ (config-if) spanning-tree port type edge
|
|
|
|
Why does X issue occur when I am using LACP bonding with iPXE?
|
|
==============================================================
|
|
|
|
If you are using iPXE, an unfortunate aspect of its design and interaction
|
|
with networking is an automatic response as a Link Aggregation Control
|
|
Protocol (or LACP) peer to remote switches. iPXE does this for only the
|
|
single port which is used for network booting.
|
|
|
|
In theory, this may help establish the port link-state faster with some
|
|
switch vendors, but the official reasoning as far as the Ironic Developers
|
|
are aware is not documented for iPXE. The end result of this is that once
|
|
iPXE has stopped responding to LACP messages from the peer port, which
|
|
occurs as part of the process of booting a ramdisk and iPXE handing
|
|
over control to a full operating-system, switches typically begin a
|
|
timer to determine how to handle the failure. This is because,
|
|
depending on the mode of LACP, this can be interpreted as a switch or
|
|
network fabric failure.
|
|
|
|
This may demonstrate as any number of behaviors or issues from ramdisks
|
|
finding they are unable to acquire DHCP addresses over the network interface
|
|
to downloads abruptly stalling, to even minor issues such as LLDP port data
|
|
being unavailable in introspection.
|
|
|
|
Overall:
|
|
|
|
* Ironic's agent doesn't officially support LACP and the Ironic community
|
|
generally believes this may cause more problems than it would solve.
|
|
During the Victoria development cycle, we added retry logic for most
|
|
actions in an attempt to navigate the worst-known default hold-down
|
|
timers to help ensure a deployment does not fail due to a short-lived
|
|
transitory network connectivity failure in the form of a switch port having
|
|
moved to a temporary blocking state. Where applicable and possible,
|
|
many of these patches have been backported to supported releases.
|
|
These patches also require that the switchport has an eventual fallback to a
|
|
non-bonded mode. If the port remains in a blocking state, then traffic will
|
|
be unable to flow and the deployment is likely to time out.
|
|
* If you must use LACP, consider ``passive`` LACP negotiation settings
|
|
in the network switch as opposed to ``active``. The difference being with
|
|
passive the connected workload is likely a server where it should likely
|
|
request the switch to establish the Link Aggregate. This is instead of
|
|
being treated as if it's possibly another switch.
|
|
* Consult your switch vendor's support forums. Some vendors have recommended
|
|
port settings for booting machines using iPXE with their switches.
|
|
|
|
IPMI errors
|
|
===========
|
|
|
|
When working with IPMI, several settings need to be enabled depending on vendors.
|
|
|
|
Enable IPMI over LAN
|
|
--------------------
|
|
|
|
Machines may not have IPMI access over LAN enabled by default. This could cause
|
|
the IPMI port to be unreachable through ipmitool, as shown:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ ipmitool -I lan -H ipmi_host -U ipmi_user -P ipmi_pass chassis power status
|
|
Error: Unable to establish LAN session
|
|
|
|
To fix this, enable `IPMI over lan` setting using your BMC tool or web app.
|
|
|
|
Troubleshooting lanplus interface
|
|
---------------------------------
|
|
|
|
When working with lanplus interfaces, you may encounter the following error:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ ipmitool -I lanplus -H ipmi_host -U ipmi_user -P ipmi_pass power status
|
|
Error in open session response message : insufficient resources for session
|
|
Error: Unable to establish IPMI v2 / RMCP+ session
|
|
|
|
To fix that issue, please enable `RMCP+ Cipher Suite3 Configuration` setting
|
|
using your BMC tool or web app.
|
|
|
|
Why are my nodes stuck in a "-ing" state?
|
|
=========================================
|
|
|
|
The Ironic conductor uses states ending with ``ing`` as a signifier that
|
|
the conductor is actively working on something related to the node.
|
|
|
|
Often, this means there is an internal lock or ``reservation`` set on the node
|
|
and the conductor is downloading, uploading, or attempting to perform some
|
|
sort of Input/Output operation.
|
|
|
|
In the case the conductor gets stuck, these operations should timeout,
|
|
but there are cases in operating systems where operations are blocked until
|
|
completion. These sorts of operations can vary based on the specific
|
|
environment and operating configuration.
|
|
|
|
What can cause these sorts of failures?
|
|
---------------------------------------
|
|
|
|
Typical causes of such failures are going to be largely rooted in the concept
|
|
of ``iowait``, either in the form of downloading from a remote host or
|
|
reading or writing to the disk of the conductor. An operator can use the
|
|
`iostat <https://man7.org/linux/man-pages/man1/iostat.1.html>`_ tool to
|
|
identify the percentage of CPU time spent waiting on storage devices.
|
|
|
|
The fields that will be particularly important are the ``iowait``, ``await``,
|
|
and ``tps`` ones, which can be read about in the ``iostat`` manual page.
|
|
|
|
In the case of network file systems, for backing components such as image
|
|
caches or distributed ``tftpboot`` or ``httpboot`` folders, IO operations
|
|
failing on these can, depending on operating system and underlying client
|
|
settings, cause threads to be stuck in a blocking wait state, which is
|
|
realistically undetectable short the operating system logging connectivity
|
|
errors or even lock manager access errors.
|
|
|
|
For example with
|
|
`nfs <https://www.man7.org/linux/man-pages/man5/nfs.5.html>`_,
|
|
the underlying client recovery behavior, in terms of ``soft``, ``hard``,
|
|
``softreval``, ``nosoftreval``, will largely impact this behavior, but also
|
|
NFS server settings can impact this behavior. A solid sign that this is a
|
|
failure, is when an ``ls /path/to/nfs`` command hangs for a period of time.
|
|
In such cases, the Storage Administrator should be consulted and network
|
|
connectivity investigated for errors before trying to recover to
|
|
proceed.
|
|
|
|
The bad news for IO related failures
|
|
------------------------------------
|
|
|
|
If the node has a populated ``reservation`` field, and has not timed out or
|
|
proceeded to a ``fail`` state, then the conductor process will likely need to
|
|
be restarted. This is because the worker thread is hung with-in the conductor.
|
|
|
|
Manual intervention with-in Ironic's database is *not* advised to try and
|
|
"un-wedge" the machine in this state, and restarting the conductor is
|
|
encouraged.
|
|
|
|
.. note::
|
|
Ironic's conductor, upon restart, clears reservations for nodes which
|
|
were previously managed by the conductor before restart.
|
|
|
|
If a distributed or network file system is in use, it is highly recommended
|
|
that the operating system of the node running the conductor be rebooted as
|
|
the running conductor may not even be able to exit in the state of an IO
|
|
failure, again dependent upon site and server configuration.
|
|
|
|
File Size != Disk Size
|
|
----------------------
|
|
|
|
An easy to make misconception is that a 2.4 GB file means that only 2.4 GB
|
|
is written to disk. But if that file's virtual size is 20 GB, or 100 GB
|
|
things can become very problematic and extend the amount of time the node
|
|
spends in ``deploying`` and ``deploy wait`` states.
|
|
|
|
Again, these sorts of cases will depend upon the exact configuration of the
|
|
deployment, but hopefully these are areas where these actions can occur.
|
|
|
|
* Conversion to raw image files upon download to the conductor, from the
|
|
``[DEFAULT]force_raw_images`` option. Users using Glance may also experience
|
|
issues here as the conductor will cache the image to be written which takes
|
|
place when the ``[agent]image_download_source`` is set to ``http`` instead of
|
|
``swift``.
|
|
|
|
.. note::
|
|
The QCOW2 image conversion utility does consume quite a bit of memory
|
|
when converting images or writing them to the end storage device. This
|
|
is because the files are not sequential in nature, and must be re-assembled
|
|
from an internal block mapping. Internally Ironic limits this to 1GB
|
|
of RAM. Operators performing large numbers of deployments may wish to
|
|
disable raw images in these sorts of cases in order to minimize the
|
|
conductor becoming a limiting factor due to memory and network IO.
|
|
|
|
Why are my nodes stuck in a "wait" state?
|
|
=========================================
|
|
|
|
The Ironic conductor uses states containing ``wait`` as a signifier that
|
|
the conductor is waiting for a callback from another component, such as
|
|
the Ironic Python Agent or the Inspector. If this feedback does not arrive,
|
|
the conductor will time out and the node will eventually move to a ``failed``
|
|
state. Depending on the configuration and the circumstances, however, a node
|
|
can stay in a ``wait`` state for a long time or even never time out. The list
|
|
of such wait states includes:
|
|
|
|
* ``clean wait`` for cleaning,
|
|
* ``inspect wait`` for introspection,
|
|
* ``rescue wait`` for rescueing, and
|
|
* ``wait call-back`` for deploying.
|
|
|
|
Communication issues between the conductor and the node
|
|
-------------------------------------------------------
|
|
|
|
One of the most common issues when nodes seem to be stuck in a wait state
|
|
occur when the node never received any instructions or does not react as
|
|
expected: the conductor moved the node to a wait state but the node will
|
|
never call back. Examples include wrong ciphers which will make ipmitool
|
|
get stuck or BMCs in a state where they accept commands, but don't do the
|
|
requested task (or only a part of it, like shutting off, but not starting).
|
|
It is useful in these cases to see via a ping or the console if and which
|
|
action the node is performing. If the node does not seem to react to the
|
|
requests sent be the conductor, it may be worthwhile to try the corresponding
|
|
action out-of-band, e.g. confirm that power on/off commands work when directly
|
|
sent to the BMC. The section on `IPMI errors`_. above gives some additional
|
|
points to check. In some situations, a BMC reset may be necessary.
|
|
|
|
Ironic Python Agent stuck
|
|
-------------------------
|
|
|
|
Nodes can also get remain in a wait state when the component the conductor is
|
|
waiting for gets stuck, e.g. when a hardware manager enters a loop or is
|
|
waiting for an event that is never happening. In these cases, it might be
|
|
helpful to connect to the IPA and inspect its logs, see the trouble shooting
|
|
guide of the :ironic-python-agent-doc:`ironic-python-agent (IPA) <>` on how
|
|
to do this.
|
|
|
|
Deployments fail with "failed to update MAC address"
|
|
====================================================
|
|
|
|
The design of the integration with the Networking service (neutron) is such
|
|
that once virtual ports have been created in the API, their MAC address must
|
|
be updated in order for the DHCP server to be able to appropriately reply.
|
|
|
|
This can sometimes result in errors being raised indicating that the MAC
|
|
address is already in use. This is because at some point in the past, a
|
|
virtual interface was orphaned either by accident or by some unexpected
|
|
glitch, and a previous entry is still present in Neutron.
|
|
|
|
This error looks something like this when reported in the ironic-conductor
|
|
log output.:
|
|
|
|
Failed to update MAC address on Neutron port 305beda7-0dd0-4fec-b4d2-78b7aa4e8e6a.: MacAddressInUseClient: Unable to complete operation for network 1e252627-6223-4076-a2b9-6f56493c9bac. The mac address 52:54:00:7c:c4:56 is in use.
|
|
|
|
Because we have no idea about this entry, we fail the deployment process
|
|
as we can't make a number of assumptions in order to attempt to automatically
|
|
resolve the conflict.
|
|
|
|
How did I get here?
|
|
-------------------
|
|
|
|
Originally this was a fairly easy issue to encounter. The retry logic path
|
|
which resulted between the Orchestration (heat) and Compute (nova) services,
|
|
could sometimes result in additional un-necessary ports being created.
|
|
|
|
Bugs of this class have been largely resolved since the Rocky development
|
|
cycle. Since then, the way this can become encountered is due to Networking
|
|
(neutron) VIF attachments not being removed or deleted prior to deleting a
|
|
port in the Bare Metal service.
|
|
|
|
Ultimately, the key of this is that the port is being deleted. Under most
|
|
operating circumstances, there really is no need to delete the port, and
|
|
VIF attachments are stored on the port object, so deleting the port
|
|
*CAN* result in the VIF not being cleaned up from Neutron.
|
|
|
|
Under normal circumstances, when deleting ports, a node should be in a
|
|
stable state, and the node should not be provisioned. If the
|
|
``baremetal port delete`` command fails, this may indicate that
|
|
a known VIF is still attached. Generally if they are transitory from cleaning,
|
|
provisioning, rescuing, or even inspection, getting the node to the
|
|
``available`` state wil unblock your delete operation, that is unless there is
|
|
a tenant VIF attahment. In that case, the vif will need to be removed from
|
|
with-in the Bare Metal service using the
|
|
``baremetal node vif detach`` command.
|
|
|
|
A port can also be checked to see if there is a VIF attachment by consulting
|
|
the port's ``internal_info`` field.
|
|
|
|
.. warning::
|
|
The ``maintenance`` flag can be used to force the node's port to be
|
|
deleted, however this will disable any check that would normally block
|
|
the user from issuing a delete and accidently orphaning the VIF attachment
|
|
record.
|
|
|
|
How do I resolve this?
|
|
----------------------
|
|
|
|
Generally, you need to identify the port with the offending MAC address.
|
|
Example:
|
|
|
|
openstack port list --mac-address 52:54:00:7c:c4:56
|
|
|
|
From the command's output, you should be able to identify the ``id`` field.
|
|
Using that, you can delete the port. Example:
|
|
|
|
openstack port delete <id>
|
|
|
|
.. warning::
|
|
Before deleting a port, you should always verify that it is no longer in
|
|
use or no longer seems applicable/operable. If multiple deployments of
|
|
the Bare Metal service with a single Neutron, the possibility that a
|
|
inventory typo, or possibly even a duplicate MAC address exists, which
|
|
could also produce the same basic error message.
|
|
|
|
My test VM image does not deploy -- mount point does not exist
|
|
==============================================================
|
|
|
|
What is likely occuring
|
|
-----------------------
|
|
|
|
The image attempting to be deployed likely is a partition image where
|
|
the file system that the user wishes to boot from lacks the required
|
|
folders, such as ``/dev`` and ``/proc``, which are required to install
|
|
a bootloader for a Linux OS image
|
|
|
|
It should be noted that similar errors can also occur with whole disk
|
|
images where we are attempting to setup the UEFI bootloader configuration.
|
|
That being said, in this case, the image is likely invalid or contains
|
|
an unexpected internal structure.
|
|
|
|
Users performing testing may choose something that they believe
|
|
will work based on it working for virtual machines. These images are often
|
|
attractive for testing as they are generic and include basic support
|
|
for establishing networking and possibly installing user keys.
|
|
Unfortunately, these images often lack drivers and firmware required for
|
|
many different types of physical hardware which makes using them
|
|
very problematic. Additionally, images such as `Cirros <https://download.cirros-cloud.net>`_
|
|
do not have any contents in the root filesystem (i.e. an empty filesystem),
|
|
as they are designed for the ``ramdisk`` to write the contents to disk upon
|
|
boot.
|
|
|
|
How do I not encounter this issue?
|
|
----------------------------------
|
|
|
|
We generally recommend using `diskimage-builder <https://docs.openstack.org/diskimage-builder>`_
|
|
or vendor supplied images. Centos, Ubuntu, Fedora, and Debian all publish
|
|
operating system images which do generally include drivers and firmware for
|
|
physical hardware. Many of these published "cloud" images, also support
|
|
auto-configuration of networking AND population of user keys.
|
|
|
|
Issues with autoconfigured TLS
|
|
==============================
|
|
|
|
These issues will manifest as an error in ``ironic-conductor`` logs looking
|
|
similar to (lines are wrapped for readability)::
|
|
|
|
ERROR ironic.drivers.modules.agent_client [-]
|
|
Failed to connect to the agent running on node d7c322f0-0354-4008-92b4-f49fb2201001
|
|
for invoking command clean.get_clean_steps. Error:
|
|
HTTPSConnectionPool(host='192.168.123.126', port=9999): Max retries exceeded with url:
|
|
/v1/commands/?wait=true&agent_token=<token> (Caused by
|
|
SSLError(SSLError(1, '[SSL: CERTIFICATE_VERIFY_FAILED] certificate verify failed (_ssl.c:897)'),)):
|
|
requests.exceptions.SSLError: HTTPSConnectionPool(host='192.168.123.126', port=9999):
|
|
Max retries exceeded with url: /v1/commands/?wait=true&agent_token=<token>
|
|
(Caused by SSLError(SSLError(1, '[SSL: CERTIFICATE_VERIFY_FAILED] certificate verify failed (_ssl.c:897)'),))
|
|
|
|
The cause of the issue is that the Bare Metal service cannot access the ramdisk
|
|
with the TLS certificate provided by the ramdisk on first heartbeat. You can
|
|
inspect the stored certificate in ``/var/lib/ironic/certificates/<node>.crt``.
|
|
|
|
You can try connecting to the ramdisk using the IP address in the log message::
|
|
|
|
curl -vL https://<IP address>:9999/v1/commands \
|
|
--cacert /var/lib/ironic/certificates/<node UUID>.crt
|
|
|
|
You can get the detailed information about the certificate using openSSL::
|
|
|
|
openssl x509 -text -noout -in /var/lib/ironic/certificates/<node UUID>.crt
|
|
|
|
Clock skew
|
|
----------
|
|
|
|
One possible source of the problem is a discrepancy between the hardware
|
|
clock on the node and the time on the machine with the Bare Metal service.
|
|
It can be detected by comparing the ``Not Before`` field in the ``openssl``
|
|
output with the timestamp of a log message.
|
|
|
|
The recommended solution is to enable the NTP support in ironic-python-agent by
|
|
passing the ``ipa-ntp-server`` argument with an address of an NTP server
|
|
reachable by the node.
|
|
|
|
If it is not possible, you need to ensure the correct hardware time on the
|
|
machine. Keep in mind a potential issue with timezones: an ability to store
|
|
timezone in hardware is pretty recent and may not be available. Since
|
|
ironic-python-agent is likely operating in UTC, the hardware clock should also
|
|
be set in UTC.
|
|
|
|
.. note::
|
|
Microsoft Windows uses local time by default, so a machine that has
|
|
previously run Windows will likely have wrong time.
|
|
|
|
I changed ironic.conf, and now I can't edit my nodes.
|
|
=====================================================
|
|
|
|
Whenever a node is created in ironic, default interfaces are identified
|
|
as part of driver composition. This maybe sourced from explicit default
|
|
values which have been set in ``ironic.conf`` or by the interface order
|
|
for the enabled interfaces list. The result of this is that the
|
|
``ironic-conductor`` cannot spawn a ``task`` using the composed driver,
|
|
as a portion of the driver is no longer enabled. This makes it difficult
|
|
to edit or update the node if the settings have been changed.
|
|
|
|
For example, with networking interfaces, if you have
|
|
``default_network_interface=neutron`` or
|
|
``enabled_network_interfaces=neutron,flat``
|
|
in your ``ironic.conf``, nodes would have been created with the ``neutron``
|
|
network interface.
|
|
|
|
This is because ``default_network_interface`` overrides the setting
|
|
for new nodes, and that setting is **saved** to the database nodes table.
|
|
|
|
Similarly, the order of ``enabled_network_interfaces`` takes priority, and
|
|
the first entry in the list is generally set to the default for the node upon
|
|
creation, and that record is **saved** to the database nodes table.
|
|
|
|
The only case where driver composition does *not* calculate a default is if
|
|
an explicit value is provided upon the creation of the node.
|
|
|
|
Example failure
|
|
---------------
|
|
|
|
A node in this state, when the ``network_interface`` was saved as ``neutron``,
|
|
yet the ``neutron`` interface is no longer enabled will fail basic state
|
|
transition requests.:
|
|
|
|
$ baremetal node manage 7164efca-37ab-1213-1112-b731cf795a5a
|
|
Could not find the following interface in the 'ironic.hardware.interfaces.network' entrypoint: neutron. Valid interfaces are ['flat']. (HTTP 400)
|
|
|
|
How to fix this?
|
|
----------------
|
|
|
|
Revert the changes you made to ``ironic.conf``.
|
|
|
|
This applies to any changes to any ``default_*_interface`` options or the
|
|
order of interfaces in the for the ``enabled_*_interfaces`` options.
|
|
|
|
Once the conductor has been restarted with the updated configuration, you
|
|
should now be able to update the interface using the ``baremetal node set``
|
|
command. In this example we use the ``network_interface`` as this is most
|
|
commonly where it is encountered.:
|
|
|
|
$ baremetal node set $NAME_OR_UUID --network-interface flat
|
|
|
|
.. note:: There are additional paths one can take to remedy this sort of
|
|
issue, however we encourage operators to be mindful of operational
|
|
consistency when making major configuration changes.
|
|
|
|
Once you have updated the saved interfaces, you should be able to safely
|
|
return the ``ironic.conf`` configuration change in changing what interfaces
|
|
are enabled by the conductor.
|
|
|
|
I'm getting Out of Memory errors
|
|
================================
|
|
|
|
This issue, also known as the "the OOMKiller got my conductor" case,
|
|
is where your OS system memory reaches a point where the operating
|
|
system engages measures to shed active memory consumption in order
|
|
to prevent a complete failure of the machine. Unfortunately this
|
|
can cause unpredictable behavior.
|
|
|
|
How did I get here?
|
|
-------------------
|
|
|
|
One of the major consumers of memory in a host running an ironic-conductor is
|
|
transformation of disk images using the ``qemu-img`` tool. This tool, because
|
|
the disk images it works with are both compressed and out of linear block
|
|
order, requires a considerable amount of memory to efficently re-assemble
|
|
and write-out a disk to a device, or to simply convert the format such as
|
|
to a ``raw`` image.
|
|
|
|
By default, ironic's configuration limits this conversion to 1 GB of RAM
|
|
for the process, but each conversion does cause additional buffer memory
|
|
to be used, which increases overall system memory pressure. Generally
|
|
memory pressure alone from buffers will not cause an out of memory condition,
|
|
but the multiple conversions or deployments running at the same time
|
|
CAN cause extreme memory pressure and risk the system running out of memory.
|
|
|
|
How do I resolve this?
|
|
----------------------
|
|
|
|
This can be addressed a few different ways:
|
|
|
|
* Use raw images, however these images can be substantially larger
|
|
and require more data to be transmitted "over the wire".
|
|
* Add more physical memory.
|
|
* Add swap space.
|
|
* Reduce concurrency, possibly via another conductor or changing the
|
|
nova-compute.conf ``max_concurrent_builds`` parameter.
|
|
* Or finally, adjust the ``[DEFAULT]minimum_required_memory`` parameter
|
|
in your ironic.conf file. The default should be considered a "default
|
|
of last resort" and you may need to reserve additional memory. You may
|
|
also wish to adjust the ``[DEFAULT]minimum_memory_wait_retries`` and
|
|
``[DEFAULT]minimum_memory_wait_time`` parameters.
|