.. _ilo:
|
|
|
|
===========
|
|
iLO drivers
|
|
===========
|
|
|
|
Overview
|
|
========
|
|
iLO drivers enable to take advantage of features of iLO management engine in
|
|
HPE ProLiant servers. iLO drivers are targeted for HPE ProLiant Gen 8 systems
|
|
and above which have `iLO 4 management engine <http://www8.hp.com/us/en/products/servers/ilo>`_.
|
|
|
|
For more details, please refer the iLO driver document of Juno, Kilo and Liberty releases,
|
|
and for up-to-date information (like tested platforms, known issues, etc), please check the
|
|
`iLO driver wiki page <https://wiki.openstack.org/wiki/Ironic/Drivers/iLODrivers>`_.
|
|
|
|
Currently there are 3 iLO drivers:
|
|
|
|
* ``iscsi_ilo``
|
|
* ``agent_ilo``
|
|
* ``pxe_ilo``.
|
|
|
|
The ``iscsi_ilo`` and ``agent_ilo`` drivers provide security enhanced
|
|
PXE-less deployment by using iLO virtual media to boot up the bare metal node.
|
|
These drivers send management info through management channel and separates
|
|
it from data channel which is used for deployment.
|
|
|
|
``iscsi_ilo`` and ``agent_ilo`` drivers use deployment ramdisk
|
|
built from ``diskimage-builder``. The ``iscsi_ilo`` driver deploys from
|
|
ironic conductor and supports both net-boot and local-boot of instance.
|
|
``agent_ilo`` deploys from bare metal node and always does local-boot.
|
|
|
|
``pxe_ilo`` driver uses PXE/iSCSI for deployment (just like normal PXE driver)
|
|
and deploys from ironic conductor. Additionally it supports automatic setting of
|
|
requested boot mode from nova. This driver doesn't require iLO Advanced license.
|
|
|
|
|
|
Prerequisites
|
|
=============
|
|
|
|
* `proliantutils <https://pypi.python.org/pypi/proliantutils>`_ is a python package
|
|
which contains set of modules for managing HPE ProLiant hardware.
|
|
|
|
Install ``proliantutils`` module on the ironic conductor node. Minimum
|
|
version required is 2.1.7.::
|
|
|
|
$ pip install "proliantutils>=2.1.7"
|
|
|
|
* ``ipmitool`` command must be present on the service node(s) where
|
|
``ironic-conductor`` is running. On most distros, this is provided as part
|
|
of the ``ipmitool`` package. Refer to `Hardware Inspection Support`_ for more
|
|
information on recommended version.
|
|
|
|
Different Configuration for ilo drivers
|
|
=======================================
|
|
|
|
Glance Configuration
|
|
^^^^^^^^^^^^^^^^^^^^
|
|
|
|
1. `Configure Glance image service with its storage backend as Swift
|
|
<http://docs.openstack.org/developer/glance/configuring.html#configuring-the-swift-storage-backend>`_.
|
|
|
|
2. Set a temp-url key for Glance user in Swift. For example, if you have
|
|
configured Glance with user ``glance-swift`` and tenant as ``service``,
|
|
then run the below command::
|
|
|
|
swift --os-username=service:glance-swift post -m temp-url-key:mysecretkeyforglance
|
|
|
|
3. Fill the required parameters in the ``[glance]`` section in
|
|
``/etc/ironic/ironic.conf``. Normally you would be required to fill in the
|
|
following details.::
|
|
|
|
[glance]
|
|
swift_temp_url_key=mysecretkeyforglance
|
|
swift_endpoint_url=https://10.10.1.10:8080
|
|
swift_api_version=v1
|
|
swift_account=AUTH_51ea2fb400c34c9eb005ca945c0dc9e1
|
|
swift_container=glance
|
|
|
|
The details can be retrieved by running the below command:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ swift --os-username=service:glance-swift stat -v | grep -i url
|
|
|
|
StorageURL: http://10.10.1.10:8080/v1/AUTH_51ea2fb400c34c9eb005ca945c0dc9e1
|
|
Meta Temp-Url-Key: mysecretkeyforglance
|
|
|
|
|
|
4. Swift must be accessible with the same admin credentials configured in
|
|
Ironic. For example, if Ironic is configured with the below credentials in
|
|
``/etc/ironic/ironic.conf``.::
|
|
|
|
[keystone_authtoken]
|
|
admin_password = password
|
|
admin_user = ironic
|
|
admin_tenant_name = service
|
|
|
|
Ensure ``auth_version`` in ``keystone_authtoken`` to 2.
|
|
|
|
Then, the below command should work.:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ swift --os-username ironic --os-password password --os-tenant-name service --auth-version 2 stat
|
|
|
|
Account: AUTH_22af34365a104e4689c46400297f00cb
|
|
Containers: 2
|
|
Objects: 18
|
|
Bytes: 1728346241
|
|
Objects in policy "policy-0": 18
|
|
Bytes in policy "policy-0": 1728346241
|
|
Meta Temp-Url-Key: mysecretkeyforglance
|
|
X-Timestamp: 1409763763.84427
|
|
X-Trans-Id: tx51de96a28f27401eb2833-005433924b
|
|
Content-Type: text/plain; charset=utf-8
|
|
Accept-Ranges: bytes
|
|
|
|
5. Restart the Ironic conductor service.::
|
|
|
|
$ service ironic-conductor restart
|
|
|
|
Web server configuration on conductor
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
* The HTTP(S) web server can be configured in many ways. For apache
|
|
web server on Ubuntu, refer `here <https://help.ubuntu.com/lts/serverguide/httpd.html>`_
|
|
|
|
* Following config variables need to be set in
|
|
``/etc/ironic/ironic.conf``:
|
|
|
|
* ``use_web_server_for_images`` in ``[ilo]`` section::
|
|
|
|
[ilo]
|
|
use_web_server_for_images = True
|
|
|
|
* ``http_url`` and ``http_root`` in ``[deploy]`` section::
|
|
|
|
[deploy]
|
|
# Ironic compute node's http root path. (string value)
|
|
http_root=/httpboot
|
|
|
|
# Ironic compute node's HTTP server URL. Example:
|
|
# http://192.1.2.3:8080 (string value)
|
|
http_url=http://192.168.0.2:8080
|
|
|
|
``use_web_server_for_images``: If the variable is set to ``false``, ``iscsi_ilo``
|
|
and ``agent_ilo`` uses swift containers to host the intermediate floppy
|
|
image and the boot ISO. If the variable is set to ``true``, these drivers
|
|
uses the local web server for hosting the intermediate files. The default value
|
|
for ``use_web_server_for_images`` is False.
|
|
|
|
``http_url``: The value for this variable is prefixed with the generated
|
|
intermediate files to generate a URL which is attached in the virtual media.
|
|
|
|
``http_root``: It is the directory location to which ironic conductor copies
|
|
the intermediate floppy image and the boot ISO.
|
|
|
|
.. note::
|
|
HTTPS is strongly recommended over HTTP web server configuration for security
|
|
enhancement. The ``iscsi_ilo`` and ``agent_ilo`` will send the instance's
|
|
configdrive over an encrypted channel if web server is HTTPS enabled.
|
|
|
|
Enable driver
|
|
=============
|
|
|
|
1. Build a deploy ISO (and kernel and ramdisk) image, see :ref:`BuildingDibBasedDeployRamdisk`
|
|
|
|
2. See `Glance Configuration`_ for configuring glance image service with its storage
|
|
backend as ``swift``.
|
|
|
|
3. Upload this image to Glance.::
|
|
|
|
glance image-create --name deploy-ramdisk.iso --disk-format iso --container-format bare < deploy-ramdisk.iso
|
|
|
|
4. Add the driver name to the list of ``enabled_drivers`` in
|
|
``/etc/ironic/ironic.conf``. For example, for `iscsi_ilo` driver::
|
|
|
|
enabled_drivers = fake,pxe_ssh,pxe_ipmitool,iscsi_ilo
|
|
|
|
Similarly it can be added for ``agent_ilo`` and ``pxe_ilo`` drivers.
|
|
|
|
5. Restart the ironic conductor service.::
|
|
|
|
$ service ironic-conductor restart
|
|
|
|
Drivers
|
|
=======
|
|
|
|
iscsi_ilo driver
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
Overview
|
|
~~~~~~~~
|
|
``iscsi_ilo`` driver was introduced as an alternative to ``pxe_ipmitool``
|
|
and ``pxe_ipminative`` drivers for HPE ProLiant servers. ``iscsi_ilo`` uses
|
|
virtual media feature in iLO to boot up the bare metal node instead of using
|
|
PXE or iPXE.
|
|
|
|
Target Users
|
|
~~~~~~~~~~~~
|
|
|
|
* Users who do not want to use PXE/TFTP protocol on their data centres.
|
|
|
|
* Users who have concerns with PXE protocol's security issues and want to have a
|
|
security enhanced PXE-less deployment mechanism.
|
|
|
|
The PXE driver passes management information in clear-text to the
|
|
bare metal node. However, if swift proxy server has an HTTPS
|
|
endpoint (See :ref:`EnableHTTPSinSwift` for more information), the
|
|
``iscsi_ilo`` driver provides enhanced security by passing
|
|
management information to and from swift endpoint over HTTPS. The
|
|
management information, deploy ramdisk and boot images for the instance will
|
|
be retrieved over encrypted management network via iLO virtual media.
|
|
|
|
Tested Platforms
|
|
~~~~~~~~~~~~~~~~
|
|
This driver should work on HPE ProLiant Gen8 Servers and above with iLO 4.
|
|
It has been tested with the following servers:
|
|
|
|
* ProLiant DL380e Gen8
|
|
* ProLiant DL580 Gen8 UEFI
|
|
* ProLiant DL180 Gen9 UEFI
|
|
* ProLiant DL360 Gen9 UEFI
|
|
* ProLiant DL380 Gen9 UEFI
|
|
|
|
For more up-to-date information on server platform support info, refer
|
|
`iLO driver wiki page <https://wiki.openstack.org/wiki/Ironic/Drivers/iLODrivers>`_.
|
|
|
|
Features
|
|
~~~~~~~~
|
|
* PXE-less deploy with virtual media.
|
|
* Automatic detection of current boot mode.
|
|
* Automatic setting of the required boot mode, if UEFI boot mode is requested
|
|
by the nova flavor's extra spec.
|
|
* Supports booting the instance from virtual media (netboot) as well as booting
|
|
locally from disk. By default, the instance will always boot from virtual
|
|
media for partition images.
|
|
* UEFI Boot Support
|
|
* UEFI Secure Boot Support
|
|
* Passing management information via secure, encrypted management network
|
|
(virtual media) if swift proxy server has an HTTPS endpoint. See
|
|
:ref:`EnableHTTPSinSwift` for more info. User image provisioning is done
|
|
using iSCSI over data network, so this driver has the benefit
|
|
of security enhancement with the same performance. It segregates management
|
|
info from data channel.
|
|
* Support for out-of-band cleaning operations.
|
|
* Remote Console
|
|
* HW Sensors
|
|
* Works well for machines with resource constraints (lesser amount of memory).
|
|
* Support for out-of-band hardware inspection.
|
|
* Swiftless deploy for intermediate images
|
|
* HTTP(S) Based Deploy.
|
|
* iLO drivers with standalone ironic.
|
|
|
|
Requirements
|
|
~~~~~~~~~~~~
|
|
* **iLO 4 Advanced License** needs to be installed on iLO to enable Virtual
|
|
Media feature.
|
|
* **Swift Object Storage Service** - iLO driver uses swift to store temporary
|
|
FAT images as well as boot ISO images.
|
|
* **Glance Image Service with swift configured as its backend** - When using
|
|
``iscsi_ilo`` driver, the image containing the deploy ramdisk is retrieved
|
|
from swift directly by the iLO.
|
|
|
|
|
|
Deploy Process
|
|
~~~~~~~~~~~~~~
|
|
|
|
Refer to `Netboot with glance and swift`_ for the deploy process of partition image
|
|
and `Localboot with glance and swift`_ for the deploy process of whole disk image.
|
|
|
|
Configuring and Enabling the driver
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Refer to `Glance Configuration`_ and `Enable driver`_.
|
|
|
|
Registering ProLiant node in ironic
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Nodes configured for iLO driver should have the ``driver`` property set to
|
|
``iscsi_ilo``. The following configuration values are also required in
|
|
``driver_info``:
|
|
|
|
- ``ilo_address``: IP address or hostname of the iLO.
|
|
- ``ilo_username``: Username for the iLO with administrator privileges.
|
|
- ``ilo_password``: Password for the above iLO user.
|
|
- ``ilo_deploy_iso``: The glance UUID of the deploy ramdisk ISO image.
|
|
- ``client_port``: (optional) Port to be used for iLO operations if you are
|
|
using a custom port on the iLO. Default port used is 443.
|
|
- ``client_timeout``: (optional) Timeout for iLO operations. Default timeout
|
|
is 60 seconds.
|
|
- ``console_port``: (optional) Node's UDP port for console access. Any unused
|
|
port on the ironic conductor node may be used.
|
|
|
|
For example, you could run a similar command like below to enroll the ProLiant
|
|
node::
|
|
|
|
ironic node-create -d iscsi_ilo -i ilo_address=<ilo-ip-address> -i ilo_username=<ilo-username> -i ilo_password=<ilo-password> -i ilo_deploy_iso=<glance-uuid-of-deploy-iso>
|
|
|
|
Boot modes
|
|
~~~~~~~~~~
|
|
Refer to `Boot mode support`_ section for more information.
|
|
|
|
UEFI Secure Boot
|
|
~~~~~~~~~~~~~~~~
|
|
Refer to `UEFI Secure Boot Support`_ section for more information.
|
|
|
|
Node cleaning
|
|
~~~~~~~~~~~~~
|
|
Refer to `Node Cleaning Support`_ for more information.
|
|
|
|
Hardware Inspection
|
|
~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Hardware Inspection Support`_ for more information.
|
|
|
|
Swiftless deploy for intermediate deploy and boot images
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Swiftless deploy for intermediate images`_ for more information.
|
|
|
|
HTTP(S) Based Deploy
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `HTTP(S) Based Deploy Support`_ for more information.
|
|
|
|
iLO drivers with standalone ironic
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Support for iLO drivers with Standalone Ironic`_ for more information.
|
|
|
|
agent_ilo driver
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
Overview
|
|
~~~~~~~~
|
|
``agent_ilo`` driver was introduced as an alternative to ``agent_ipmitool``
|
|
and ``agent_ipminative`` drivers for HPE ProLiant servers. ``agent_ilo`` driver
|
|
uses virtual media feature in HPE ProLiant bare metal servers to boot up the
|
|
Ironic Python Agent (IPA) on the bare metal node instead of using PXE. For
|
|
more information on IPA, refer
|
|
https://wiki.openstack.org/wiki/Ironic-python-agent.
|
|
|
|
Target Users
|
|
~~~~~~~~~~~~
|
|
* Users who do not want to use PXE/TFTP protocol on their data centres.
|
|
* Users who have concerns on PXE based agent driver's security and
|
|
want to have a security enhanced PXE-less deployment mechanism.
|
|
|
|
The PXE based agent drivers pass management information in clear-text to
|
|
the bare metal node. However, if swift proxy server has an HTTPS
|
|
endpoint (See :ref:`EnableHTTPSinSwift` for more information),
|
|
the ``agent_ilo`` driver provides enhanced security by passing authtoken
|
|
and management information to and from swift endpoint over HTTPS. The
|
|
management information and deploy ramdisk will be retrieved over encrypted
|
|
management network via iLO.
|
|
|
|
Tested Platforms
|
|
~~~~~~~~~~~~~~~~
|
|
This driver should work on HPE ProLiant Gen8 Servers and above with iLO 4.
|
|
It has been tested with the following servers:
|
|
|
|
* ProLiant DL380e Gen8
|
|
* ProLiant DL580e Gen8
|
|
* ProLiant DL360 Gen9 UEFI
|
|
* ProLiant DL380 Gen9 UEFI
|
|
* ProLiant DL180 Gen9 UEFI
|
|
|
|
For more up-to-date information, check the
|
|
`iLO driver wiki page <https://wiki.openstack.org/wiki/Ironic/Drivers/iLODrivers>`_.
|
|
|
|
Features
|
|
~~~~~~~~
|
|
* PXE-less deploy with virtual media using Ironic Python Agent(IPA).
|
|
* Support for out-of-band cleaning operations.
|
|
* Remote Console
|
|
* HW Sensors
|
|
* IPA runs on the bare metal node and pulls the image directly from swift.
|
|
* IPA deployed instances always boots from local disk.
|
|
* Segregates management info from data channel.
|
|
* UEFI Boot Support
|
|
* UEFI Secure Boot Support
|
|
* Support to use default in-band cleaning operations supported by
|
|
Ironic Python Agent. For more details, see :ref:`InbandvsOutOfBandCleaning`.
|
|
* Support for out-of-band hardware inspection.
|
|
* Swiftless deploy for intermediate images.
|
|
* HTTP(S) Based Deploy.
|
|
* iLO drivers with standalone ironic.
|
|
|
|
Requirements
|
|
~~~~~~~~~~~~
|
|
* **iLO 4 Advanced License** needs to be installed on iLO to enable Virtual
|
|
Media feature.
|
|
* **Swift Object Storage Service** - iLO driver uses swift to store temporary
|
|
FAT images as well as boot ISO images.
|
|
* **Glance Image Service with swift configured as its backend** - When using
|
|
``agent_ilo`` driver, the image containing the agent is retrieved from
|
|
swift directly by the iLO.
|
|
|
|
Deploy Process
|
|
~~~~~~~~~~~~~~
|
|
|
|
Refer to `Localboot with glance and swift`_ for details.
|
|
|
|
Configuring and Enabling the driver
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Refer to `Glance Configuration`_ and `Enable driver`_.
|
|
|
|
Registering ProLiant node in ironic
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Nodes configured for iLO driver should have the ``driver`` property set to
|
|
``agent_ilo``. The following configuration values are also required in
|
|
``driver_info``:
|
|
|
|
- ``ilo_address``: IP address or hostname of the iLO.
|
|
- ``ilo_username``: Username for the iLO with administrator privileges.
|
|
- ``ilo_password``: Password for the above iLO user.
|
|
- ``ilo_deploy_iso``: The glance UUID of the deploy ramdisk ISO image.
|
|
- ``client_port``: (optional) Port to be used for iLO operations if you are
|
|
using a custom port on the iLO. Default port used is 443.
|
|
- ``client_timeout``: (optional) Timeout for iLO operations. Default timeout
|
|
is 60 seconds.
|
|
- ``console_port``: (optional) Node's UDP port for console access. Any unused
|
|
port on the ironic conductor node may be used.
|
|
|
|
For example, you could run a similar command like below to enroll the ProLiant
|
|
node::
|
|
|
|
ironic node-create -d agent_ilo -i ilo_address=<ilo-ip-address> -i ilo_username=<ilo-username> -i ilo_password=<ilo-password> -i ilo_deploy_iso=<glance-uuid-of-deploy-iso>
|
|
|
|
Boot modes
|
|
~~~~~~~~~~
|
|
Refer to `Boot mode support`_ section for more information.
|
|
|
|
UEFI Secure Boot
|
|
~~~~~~~~~~~~~~~~
|
|
Refer to `UEFI Secure Boot Support`_ section for more information.
|
|
|
|
Node Cleaning
|
|
~~~~~~~~~~~~~
|
|
Refer to `Node Cleaning Support`_ for more information.
|
|
|
|
Hardware Inspection
|
|
~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Hardware Inspection Support`_ for more information.
|
|
|
|
Swiftless deploy for intermediate deploy and boot images
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Swiftless deploy for intermediate images`_ for more information.
|
|
|
|
HTTP(S) Based Deploy
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `HTTP(S) Based Deploy Support`_ for more information.
|
|
|
|
iLO drivers with standalone ironic
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Support for iLO drivers with Standalone Ironic`_ for more information.
|
|
|
|
pxe_ilo driver
|
|
^^^^^^^^^^^^^^
|
|
|
|
Overview
|
|
~~~~~~~~
|
|
``pxe_ilo`` driver uses PXE/iSCSI (just like ``pxe_ipmitool`` driver) to
|
|
deploy the image and uses iLO to do power and management operations on the
|
|
bare metal node(instead of using IPMI).
|
|
|
|
Target Users
|
|
~~~~~~~~~~~~
|
|
* Users who want to use PXE/iSCSI for deployment in their environment or who
|
|
don't have Advanced License in their iLO.
|
|
* Users who don't want to configure boot mode manually on the bare metal node.
|
|
|
|
Tested Platforms
|
|
~~~~~~~~~~~~~~~~
|
|
This driver should work on HPE ProLiant Gen8 Servers and above with iLO 4.
|
|
It has been tested with the following servers:
|
|
|
|
* ProLiant DL380e Gen8
|
|
* ProLiant DL380e Gen8
|
|
* ProLiant DL580 Gen8 (BIOS/UEFI)
|
|
* ProLiant DL360 Gen9 UEFI
|
|
* ProLiant DL380 Gen9 UEFI
|
|
|
|
For more up-to-date information, check the
|
|
`iLO driver wiki page <https://wiki.openstack.org/wiki/Ironic/Drivers/iLODrivers>`_.
|
|
|
|
Features
|
|
~~~~~~~~
|
|
* Automatic detection of current boot mode.
|
|
* Automatic setting of the required boot mode, if UEFI boot mode is requested
|
|
by the nova flavor's extra spec.
|
|
* Support for out-of-band cleaning operations.
|
|
* Support for out-of-band hardware inspection.
|
|
* Supports UEFI Boot mode
|
|
* Supports UEFI Secure Boot
|
|
* HTTP(S) Based Deploy.
|
|
|
|
Requirements
|
|
~~~~~~~~~~~~
|
|
None.
|
|
|
|
Configuring and Enabling the driver
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
1. Build a deploy image, see :ref:`BuildingDibBasedDeployRamdisk`
|
|
|
|
2. Upload this image to glance.::
|
|
|
|
glance image-create --name deploy-ramdisk.kernel --disk-format aki --container-format aki < deploy-ramdisk.kernel
|
|
glance image-create --name deploy-ramdisk.initramfs --disk-format ari --container-format ari < deploy-ramdisk.initramfs
|
|
|
|
3. Add ``pxe_ilo`` to the list of ``enabled_drivers`` in
|
|
``/etc/ironic/ironic.conf``. For example:::
|
|
|
|
enabled_drivers = fake,pxe_ssh,pxe_ipmitool,pxe_ilo
|
|
|
|
4. Restart the ironic conductor service.::
|
|
|
|
service ironic-conductor restart
|
|
|
|
Registering ProLiant node in ironic
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Nodes configured for iLO driver should have the ``driver`` property set to
|
|
``pxe_ilo``. The following configuration values are also required in
|
|
``driver_info``:
|
|
|
|
- ``ilo_address``: IP address or hostname of the iLO.
|
|
- ``ilo_username``: Username for the iLO with administrator privileges.
|
|
- ``ilo_password``: Password for the above iLO user.
|
|
- ``deploy_kernel``: The glance UUID of the deployment kernel.
|
|
- ``deploy_ramdisk``: The glance UUID of the deployment ramdisk.
|
|
- ``client_port``: (optional) Port to be used for iLO operations if you are
|
|
using a custom port on the iLO. Default port used is 443.
|
|
- ``client_timeout``: (optional) Timeout for iLO operations. Default timeout
|
|
is 60 seconds.
|
|
- ``console_port``: (optional) Node's UDP port for console access. Any unused
|
|
port on the ironic conductor node may be used.
|
|
|
|
For example, you could run a similar command like below to enroll the ProLiant
|
|
node::
|
|
|
|
ironic node-create -d pxe_ilo -i ilo_address=<ilo-ip-address> -i ilo_username=<ilo-username> -i ilo_password=<ilo-password> -i deploy_kernel=<glance-uuid-of-pxe-deploy-kernel> -i deploy_ramdisk=<glance-uuid-of-deploy-ramdisk>
|
|
|
|
Boot modes
|
|
~~~~~~~~~~
|
|
Refer to `Boot mode support`_ section for more information.
|
|
|
|
UEFI Secure Boot
|
|
~~~~~~~~~~~~~~~~
|
|
Refer to `UEFI Secure Boot Support`_ section for more information.
|
|
|
|
Node Cleaning
|
|
~~~~~~~~~~~~~
|
|
Refer to `Node Cleaning Support`_ for more information.
|
|
|
|
Hardware Inspection
|
|
~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Hardware Inspection Support`_ for more information.
|
|
|
|
HTTP(S) Based Deploy
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `HTTP(S) Based Deploy Support`_ for more information.
|
|
|
|
iLO drivers with standalone ironic
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Refer to `Support for iLO drivers with Standalone Ironic`_ for more information.
|
|
|
|
Functionalities across drivers
|
|
==============================
|
|
|
|
Boot mode support
|
|
^^^^^^^^^^^^^^^^^
|
|
The following drivers support automatic detection and setting of boot
|
|
mode (Legacy BIOS or UEFI).
|
|
|
|
* ``pxe_ilo``
|
|
* ``iscsi_ilo``
|
|
* ``agent_ilo``
|
|
|
|
* When boot mode capability is not configured:
|
|
|
|
- If the pending boot mode is set on the node then iLO drivers use that boot
|
|
mode for provisioning the baremetal ProLiant servers.
|
|
|
|
- If the pending boot mode is not set on the node then iLO drivers use 'uefi'
|
|
boot mode for UEFI capable servers and "bios" when UEFI is not supported.
|
|
|
|
* When boot mode capability is configured, the driver sets the pending boot
|
|
mode to the configured value.
|
|
|
|
* Only one boot mode (either ``uefi`` or ``bios``) can be configured for
|
|
the node.
|
|
|
|
* If the operator wants a node to boot always in ``uefi`` mode or ``bios``
|
|
mode, then they may use ``capabilities`` parameter within ``properties``
|
|
field of an ironic node.
|
|
|
|
To configure a node in ``uefi`` mode, then set ``capabilities`` as below::
|
|
|
|
ironic node-update <node-uuid> add properties/capabilities='boot_mode:uefi'
|
|
|
|
Nodes having ``boot_mode`` set to ``uefi`` may be requested by adding an
|
|
``extra_spec`` to the nova flavor::
|
|
|
|
nova flavor-key ironic-test-3 set capabilities:boot_mode="uefi"
|
|
nova boot --flavor ironic-test-3 --image test-image instance-1
|
|
|
|
If ``capabilities`` is used in ``extra_spec`` as above, nova scheduler
|
|
(``ComputeCapabilitiesFilter``) will match only ironic nodes which have
|
|
the ``boot_mode`` set appropriately in ``properties/capabilities``. It will
|
|
filter out rest of the nodes.
|
|
|
|
The above facility for matching in nova can be used in heterogeneous
|
|
environments where there is a mix of ``uefi`` and ``bios`` machines, and
|
|
operator wants to provide a choice to the user regarding boot modes. If the
|
|
flavor doesn't contain ``boot_mode`` then nova scheduler will not consider
|
|
boot mode as a placement criteria, hence user may get either a BIOS or UEFI
|
|
machine that matches with user specified flavors.
|
|
|
|
|
|
The automatic boot ISO creation for UEFI boot mode has been enabled in Kilo.
|
|
The manual creation of boot ISO for UEFI boot mode is also supported.
|
|
For the latter, the boot ISO for the deploy image needs to be built
|
|
separately and the deploy image's ``boot_iso`` property in glance should
|
|
contain the glance UUID of the boot ISO. For building boot ISO, add ``iso``
|
|
element to the diskimage-builder command to build the image. For example::
|
|
|
|
disk-image-create ubuntu baremetal iso
|
|
|
|
UEFI Secure Boot Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^
|
|
The following drivers support UEFI secure boot deploy:
|
|
|
|
* ``pxe_ilo``
|
|
* ``iscsi_ilo``
|
|
* ``agent_ilo``
|
|
|
|
The UEFI secure boot can be configured in ironic by adding
|
|
``secure_boot`` parameter in the ``capabilities`` parameter within
|
|
``properties`` field of an ironic node.
|
|
|
|
``secure_boot`` is a boolean parameter and takes value as ``true`` or
|
|
``false``.
|
|
|
|
To enable ``secure_boot`` on a node add it to ``capabilities`` as below::
|
|
|
|
ironic node-update <node-uuid> add properties/capabilities='secure_boot:true'
|
|
|
|
Alternatively see `Hardware Inspection Support`_ to know how to
|
|
automatically populate the secure boot capability.
|
|
|
|
Nodes having ``secure_boot`` set to ``true`` may be requested by adding an
|
|
``extra_spec`` to the nova flavor::
|
|
|
|
nova flavor-key ironic-test-3 set capabilities:secure_boot="true"
|
|
nova boot --flavor ironic-test-3 --image test-image instance-1
|
|
|
|
If ``capabilities`` is used in ``extra_spec`` as above, nova scheduler
|
|
(``ComputeCapabilitiesFilter``) will match only ironic nodes which have
|
|
the ``secure_boot`` set appropriately in ``properties/capabilities``. It will
|
|
filter out rest of the nodes.
|
|
|
|
The above facility for matching in nova can be used in heterogeneous
|
|
environments where there is a mix of machines supporting and not supporting
|
|
UEFI secure boot, and operator wants to provide a choice to the user
|
|
regarding secure boot. If the flavor doesn't contain ``secure_boot`` then
|
|
nova scheduler will not consider secure boot mode as a placement criteria,
|
|
hence user may get a secure boot capable machine that matches with user
|
|
specified flavors but deployment would not use its secure boot capability.
|
|
Secure boot deploy would happen only when it is explicitly specified through
|
|
flavor.
|
|
|
|
Use element ``ubuntu-signed`` or ``fedora`` to build signed deploy iso and
|
|
user images from
|
|
`diskimage-builder <https://pypi.python.org/pypi/diskimage-builder>`_.
|
|
Refer :ref:`BuildingDibBasedDeployRamdisk` for more information on building
|
|
deploy ramdisk.
|
|
|
|
The below command creates files named cloud-image-boot.iso, cloud-image.initrd,
|
|
cloud-image.vmlinuz and cloud-image.qcow2 in the current working directory.::
|
|
|
|
cd <path-to-diskimage-builder>
|
|
./bin/disk-image-create -o cloud-image ubuntu-signed baremetal iso
|
|
|
|
.. note::
|
|
In UEFI secure boot, digitally signed bootloader should be able to validate
|
|
digital signatures of kernel during boot process. This requires that the
|
|
bootloader contains the digital signatures of the kernel.
|
|
For ``iscsi_ilo`` driver, it is recommended that ``boot_iso`` property for
|
|
user image contains the glance UUID of the boot ISO.
|
|
If ``boot_iso`` property is not updated in glance for the user image, it
|
|
would create the ``boot_iso`` using bootloader from the deploy iso. This
|
|
``boot_iso`` will be able to boot the user image in UEFI secure boot
|
|
environment only if the bootloader is signed and can validate digital
|
|
signatures of user image kernel.
|
|
|
|
Ensure the public key of the signed image is loaded into bare metal to deploy
|
|
signed images.
|
|
For HPE ProLiant Gen9 servers, one can enroll public key using iLO System
|
|
Utilities UI. Please refer to section ``Accessing Secure Boot options`` in
|
|
`HP UEFI System Utilities User Guide <http://www.hp.com/ctg/Manual/c04398276.pdf>`_.
|
|
One can also refer to white paper on `Secure Boot for Linux on HP ProLiant
|
|
servers <http://h20195.www2.hp.com/V2/getpdf.aspx/4AA5-4496ENW.pdf>`_ for
|
|
additional details.
|
|
|
|
For more up-to-date information, refer
|
|
`iLO driver wiki page <https://wiki.openstack.org/wiki/Ironic/Drivers/iLODrivers>`_
|
|
|
|
.. _ilo_node_cleaning:
|
|
|
|
Node Cleaning Support
|
|
^^^^^^^^^^^^^^^^^^^^^
|
|
The following iLO drivers support node cleaning -
|
|
|
|
* ``pxe_ilo``
|
|
* ``iscsi_ilo``
|
|
* ``agent_ilo``
|
|
|
|
For more information on node cleaning, see :ref:`cleaning`
|
|
|
|
Supported **Automated** Cleaning Operations
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
* The automated cleaning operations supported are:
|
|
|
|
-``reset_bios_to_default``:
|
|
Resets system ROM settings to default. By default, enabled with priority
|
|
10. This clean step is supported only on Gen9 and above servers.
|
|
-``reset_secure_boot_keys_to_default``:
|
|
Resets secure boot keys to manufacturer's defaults. This step is supported
|
|
only on Gen9 and above servers. By default, enabled with priority 20 .
|
|
-``reset_ilo_credential``:
|
|
Resets the iLO password, if ``ilo_change_password`` is specified as part of
|
|
node's driver_info. By default, enabled with priority 30.
|
|
-``clear_secure_boot_keys``:
|
|
Clears all secure boot keys. This step is supported only on Gen9 and above
|
|
servers. By default, this step is disabled.
|
|
-``reset_ilo``:
|
|
Resets the iLO. By default, this step is disabled.
|
|
|
|
* For in-band cleaning operations supported by ``agent_ilo`` driver, see
|
|
:ref:`InbandvsOutOfBandCleaning`.
|
|
|
|
* All the automated cleaning steps have an explicit configuration option for
|
|
priority. In order to disable or change the priority of the automated clean
|
|
steps, respective configuration option for priority should be updated in
|
|
ironic.conf.
|
|
|
|
* Updating clean step priority to 0, will disable that particular clean step
|
|
and will not run during automated cleaning.
|
|
|
|
* Configuration Options for the automated clean steps are listed under
|
|
``[ilo]`` section in ironic.conf ::
|
|
|
|
- clean_priority_reset_ilo=0
|
|
- clean_priority_reset_bios_to_default=10
|
|
- clean_priority_reset_secure_boot_keys_to_default=20
|
|
- clean_priority_clear_secure_boot_keys=0
|
|
- clean_priority_reset_ilo_credential=30
|
|
- clean_priority_erase_devices=10
|
|
|
|
For more information on node automated cleaning, see :ref:`automated_cleaning`
|
|
|
|
Supported **Manual** Cleaning Operations
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
* The manual cleaning operations supported are:
|
|
|
|
-``activate_license``:
|
|
Activates the iLO Advanced license. This is an out-of-band manual cleaning
|
|
step associated with ``management`` interface. See
|
|
`Activating iLO Advanced license as manual clean step`_ for user guidance
|
|
on usage. Please note that this operation cannot be performed using virtual
|
|
media based drivers like ``iscsi_ilo`` and ``agent_ilo`` as they need this
|
|
type of advanced license already active to use virtual media to boot into
|
|
to start cleaning operation. Virtual media is an advanced feature. If an
|
|
advanced license is already active and the user wants to overwrite the
|
|
current license key, for example in case of a multi-server activation key
|
|
delivered with a flexible-quantity kit or after completing an Activation
|
|
Key Agreement (AKA), then these drivers can still be used for executing
|
|
this cleaning step.
|
|
|
|
* iLO with firmware version 1.5 is minimally required to support all the
|
|
operations.
|
|
|
|
For more information on node manual cleaning, see :ref:`manual_cleaning`
|
|
|
|
Hardware Inspection Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The following iLO drivers support hardware inspection:
|
|
|
|
* ``pxe_ilo``
|
|
* ``iscsi_ilo``
|
|
* ``agent_ilo``
|
|
|
|
.. note::
|
|
|
|
* The RAID needs to be pre-configured prior to inspection otherwise
|
|
proliantutils returns 0 for disk size.
|
|
|
|
The inspection process will discover the following essential properties
|
|
(properties required for scheduling deployment):
|
|
|
|
* ``memory_mb``: memory size
|
|
|
|
* ``cpus``: number of cpus
|
|
|
|
* ``cpu_arch``: cpu architecture
|
|
|
|
* ``local_gb``: disk size
|
|
|
|
Inspection can also discover the following extra capabilities for iLO drivers:
|
|
|
|
* ``ilo_firmware_version``: iLO firmware version
|
|
|
|
* ``rom_firmware_version``: ROM firmware version
|
|
|
|
* ``secure_boot``: secure boot is supported or not. The possible values are
|
|
'true' or 'false'. The value is returned as 'true' if secure boot is supported
|
|
by the server.
|
|
|
|
* ``server_model``: server model
|
|
|
|
* ``pci_gpu_devices``: number of gpu devices connected to the bare metal.
|
|
|
|
* ``nic_capacity``: the max speed of the embedded NIC adapter.
|
|
|
|
.. note::
|
|
|
|
* The capability ``nic_capacity`` can only be discovered if ipmitool
|
|
version >= 1.8.15 is used on the conductor. The latest version can be
|
|
downloaded from `here <http://sourceforge.net/projects/ipmitool/>`__.
|
|
* The iLO firmware version needs to be 2.10 or above for nic_capacity to be
|
|
discovered.
|
|
|
|
The operator can specify these capabilities in nova flavor for node to be selected
|
|
for scheduling::
|
|
|
|
nova flavor-key my-baremetal-flavor set capabilities:server_model="<in> Gen8"
|
|
|
|
nova flavor-key my-baremetal-flavor set capabilities:pci_gpu_devices="> 0"
|
|
|
|
nova flavor-key my-baremetal-flavor set capabilities:nic_capacity="10Gb"
|
|
|
|
nova flavor-key my-baremetal-flavor set capabilities:ilo_firmware_version="<in> 2.10"
|
|
|
|
nova flavor-key my-baremetal-flavor set capabilities:secure_boot="true"
|
|
|
|
Swiftless deploy for intermediate images
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``iscsi_ilo`` and ``agent_ilo`` drivers can deploy and boot the server
|
|
with and without ``swift`` being used for hosting the intermediate
|
|
temporary floppy image (holding metadata for deploy kernel and ramdisk)
|
|
and the boot ISO (which is required for ``iscsi_ilo`` only). A local HTTP(S)
|
|
web server on each conductor node needs to be configured. Refer
|
|
`Web server configuration on conductor`_ for more information. The HTTPS
|
|
web server needs to be enabled (instead of HTTP web server) in order to
|
|
send management information and images in encrypted channel over HTTPS.
|
|
|
|
.. note::
|
|
This feature assumes that the user inputs are on Glance which uses swift
|
|
as backend. If swift dependency has to be eliminated, please refer to
|
|
`HTTP(S) Based Deploy Support`_ also.
|
|
|
|
Deploy Process
|
|
~~~~~~~~~~~~~~
|
|
|
|
Refer to `Netboot in swiftless deploy for intermediate images`_ for partition
|
|
image support and refer to `Localboot in swiftless deploy for intermediate images`_
|
|
for whole disk image support.
|
|
|
|
HTTP(S) Based Deploy Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The user input for the images given in ``driver_info`` like ``ilo_deploy_iso``,
|
|
``deploy_kernel`` and ``deploy_ramdisk`` and in ``instance_info`` like
|
|
``image_source``, ``kernel``, ``ramdisk`` and ``ilo_boot_iso`` may also be given as
|
|
HTTP(S) URLs.
|
|
|
|
The HTTP(S) web server can be configured in many ways. For the Apache
|
|
web server on Ubuntu, refer `here <https://help.ubuntu.com/lts/serverguide/httpd.html>`_.
|
|
The web server may reside on a different system than the conductor nodes, but its URL
|
|
must be reachable by the conductor and the bare metal nodes.
|
|
|
|
Deploy Process
|
|
~~~~~~~~~~~~~~
|
|
|
|
Refer to `Netboot with HTTP(S) based deploy`_ for partition image boot and refer to
|
|
`Localboot with HTTP(S) based deploy`_ for whole disk image boot.
|
|
|
|
|
|
Support for iLO drivers with Standalone Ironic
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
It is possible to use ironic as standalone services without other
|
|
OpenStack services. iLO drivers can be used in standalone ironic.
|
|
This feature is referred to as ``iLO drivers with standalone ironic`` in this document and is
|
|
supported by following drivers:
|
|
|
|
* ``pxe_ilo``
|
|
* ``iscsi_ilo``
|
|
* ``agent_ilo``
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
The HTTP(S) web server needs to be configured as described in `HTTP(S) Based Deploy Support`_
|
|
and `Web server configuration on conductor`_ needs to be configured for hosting
|
|
intermediate images on conductor as described in
|
|
`Swiftless deploy for intermediate images`_.
|
|
|
|
Deploy Process
|
|
~~~~~~~~~~~~~~
|
|
``iscsi_ilo`` supports both netboot and localboot, while ``agent_ilo`` supports
|
|
only localboot. Refer to `Netboot in standalone ironic`_ and
|
|
`Localboot in standalone ironic`_ for details of deploy process
|
|
for netboot and localboot respectively. For ``pxe_ilo``, the deploy process
|
|
is same as native ``pxe_ipmitool`` driver.
|
|
|
|
Deploy Process
|
|
==============
|
|
|
|
Netboot with glance and swift
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Glance; Conductor; Baremetal; Swift; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Glance [label = "Download user image"];
|
|
Conductor -> Glance [label = "Get the metadata for deploy ISO"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
|
Conductor -> Swift [label = "Uploads the FAT32 image"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Swift [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Exposes the disk over iSCSI"];
|
|
Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"];
|
|
Conductor -> Conductor [label = "Generates the boot ISO"];
|
|
Conductor -> Swift [label = "Uploads the boot ISO"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for boot ISO"];
|
|
Conductor -> iLO [label = "Attaches boot ISO swift tempURL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets boot device to CDROM"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> iLO [label = "Power on the node"];
|
|
iLO -> Swift [label = "Downloads boot ISO"];
|
|
iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"];
|
|
Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"];
|
|
}
|
|
|
|
Localboot with glance and swift
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Glance; Conductor; Baremetal; Swift; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Glance [label = "Get the metadata for deploy ISO"];
|
|
Glance -> Conductor [label = "Returns the metadata for deploy ISO"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing ironic API URL and driver name"];
|
|
Conductor -> Swift [label = "Uploads the FAT32 image"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Swift [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Sends the user image HTTP(S) URL"];
|
|
IPA -> Swift [label = "Retrieves the user image on bare metal"];
|
|
IPA -> IPA [label = "Writes user image to disk"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> Baremetal [label = "Sets boot device to disk"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> iLO [label = "Power on the node"];
|
|
Baremetal -> Baremetal [label = "Boot user image from disk"];
|
|
}
|
|
|
|
Netboot in swiftless deploy for intermediate images
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Glance; Conductor; Baremetal; ConductorWebserver; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Glance [label = "Download user image"];
|
|
Conductor -> Glance [label = "Get the metadata for deploy ISO"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
|
Conductor -> ConductorWebserver [label = "Uploads the FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Swift [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Exposes the disk over iSCSI"];
|
|
Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"];
|
|
Conductor -> Conductor [label = "Generates the boot ISO"];
|
|
Conductor -> ConductorWebserver [label = "Uploads the boot ISO"];
|
|
Conductor -> iLO [label = "Attaches boot ISO URL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets boot device to CDROM"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> iLO [label = "Power on the node"];
|
|
iLO -> ConductorWebserver [label = "Downloads boot ISO"];
|
|
iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"];
|
|
Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"];
|
|
}
|
|
|
|
|
|
Localboot in swiftless deploy for intermediate images
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Glance; Conductor; Baremetal; ConductorWebserver; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Glance [label = "Get the metadata for deploy ISO"];
|
|
Glance -> Conductor [label = "Returns the metadata for deploy ISO"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
|
Conductor -> ConductorWebserver [label = "Uploads the FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Swift [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Sends the user image HTTP(S) URL"];
|
|
IPA -> Swift [label = "Retrieves the user image on bare metal"];
|
|
IPA -> IPA [label = "Writes user image to disk"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> Baremetal [label = "Sets boot device to disk"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> Baremetal [label = "Power on the node"];
|
|
Baremetal -> Baremetal [label = "Boot user image from disk"];
|
|
}
|
|
|
|
Netboot with HTTP(S) based deploy
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Webserver; Conductor; Baremetal; Swift; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Webserver [label = "Download user image"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
|
Conductor -> Swift [label = "Uploads the FAT32 image"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Webserver [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Exposes the disk over iSCSI"];
|
|
Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"];
|
|
Conductor -> Conductor [label = "Generates the boot ISO"];
|
|
Conductor -> Swift [label = "Uploads the boot ISO"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for boot ISO"];
|
|
Conductor -> iLO [label = "Attaches boot ISO swift tempURL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets boot device to CDROM"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> iLO [label = "Power on the node"];
|
|
iLO -> Swift [label = "Downloads boot ISO"];
|
|
iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"];
|
|
Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"];
|
|
}
|
|
|
|
Localboot with HTTP(S) based deploy
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Webserver; Conductor; Baremetal; Swift; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing ironic API URL and driver name"];
|
|
Conductor -> Swift [label = "Uploads the FAT32 image"];
|
|
Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Webserver [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Sends the user image HTTP(S) URL"];
|
|
IPA -> Webserver [label = "Retrieves the user image on bare metal"];
|
|
IPA -> IPA [label = "Writes user image to disk"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> Baremetal [label = "Sets boot device to disk"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> Baremetal [label = "Power on the node"];
|
|
Baremetal -> Baremetal [label = "Boot user image from disk"];
|
|
}
|
|
|
|
Netboot in standalone ironic
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Webserver; Conductor; Baremetal; ConductorWebserver; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Webserver [label = "Download user image"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
|
Conductor -> ConductorWebserver[label = "Uploads the FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Webserver [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Exposes the disk over iSCSI"];
|
|
Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"];
|
|
Conductor -> Conductor [label = "Generates the boot ISO"];
|
|
Conductor -> ConductorWebserver [label = "Uploads the boot ISO"];
|
|
Conductor -> iLO [label = "Attaches boot ISO URL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets boot device to CDROM"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> iLO [label = "Power on the node"];
|
|
iLO -> ConductorWebserver [label = "Downloads boot ISO"];
|
|
iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"];
|
|
Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"];
|
|
}
|
|
|
|
Localboot in standalone ironic
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. seqdiag::
|
|
:scale: 80
|
|
|
|
diagram {
|
|
Webserver; Conductor; Baremetal; ConductorWebserver; IPA; iLO;
|
|
activation = none;
|
|
span_height = 1;
|
|
edge_length = 250;
|
|
default_note_color = white;
|
|
default_fontsize = 14;
|
|
|
|
Conductor -> iLO [label = "Powers off the node"];
|
|
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
|
Conductor -> ConductorWebserver [label = "Uploads the FAT32 image"];
|
|
Conductor -> Conductor [label = "Generates URL for FAT32 image"];
|
|
Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"];
|
|
Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"];
|
|
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
|
Conductor -> iLO [label = "Reboot the node"];
|
|
iLO -> Webserver [label = "Downloads deploy ISO"];
|
|
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
|
IPA -> Conductor [label = "Lookup node"];
|
|
Conductor -> IPA [label = "Provides node UUID"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> IPA [label = "Sends the user image HTTP(S) URL"];
|
|
IPA -> Webserver [label = "Retrieves the user image on bare metal"];
|
|
IPA -> IPA [label = "Writes user image to disk"];
|
|
IPA -> Conductor [label = "Heartbeat"];
|
|
Conductor -> Baremetal [label = "Sets boot device to disk"];
|
|
Conductor -> IPA [label = "Power off the node"];
|
|
Conductor -> Baremetal [label = "Power on the node"];
|
|
Baremetal -> Baremetal [label = "Boot user image from disk"];
|
|
}
|
|
|
|
Activating iLO Advanced license as manual clean step
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
iLO drivers can activate the iLO Advanced license key as a manual cleaning
|
|
step. Any manual cleaning step can only be initiated when a node is in the
|
|
``manageable`` state. Once the manual cleaning is finished, the node will be
|
|
put in the ``manageable`` state again. User can follow steps from
|
|
:ref:`manual_cleaning` to initiate manual cleaning operation on a node.
|
|
|
|
An example of a manual clean step to activate license as the only clean step
|
|
could be::
|
|
|
|
'clean_steps': [{
|
|
'interface': 'management',
|
|
'step': 'activate_license',
|
|
'args': {
|
|
'ilo_license_key': 'ABC12-XXXXX-XXXXX-XXXXX-YZ345'
|
|
}
|
|
}]
|
|
|
|
The different attributes of ``activate_license`` clean step are as follows:
|
|
|
|
.. csv-table::
|
|
:header: "Attribute", "Description"
|
|
:widths: 30, 120
|
|
|
|
"``interface``", "Interface of clean step, here ``management``"
|
|
"``step``", "Name of clean step, here ``activate_license``"
|
|
"``args``", "Keyword-argument entry (<name>: <value>) being passed to clean step"
|
|
"``args.ilo_license_key``", "The HPE iLO Advanced license key to activate enterprise features. This is mandatory."
|