This updates the documentation to include manual cleaning. Change-Id: I8f91214911e8916c329c20a140e1d0957b1cc137 Partial-Bug: #1526290
4.2 KiB
Bare Metal Service Upgrade Guide
This document outlines various steps and notes for operators to consider when upgrading their Ironic-driven clouds from previous versions of OpenStack.
The Ironic service is tightly coupled with the Ironic driver that is shipped with Nova. Currently, some special considerations must be taken into account when upgrading your cloud from previous versions of OpenStack.
Upgrading from Kilo to Liberty
In-band Inspection
If you used in-band inspection with ironic-discoverd, you have to install python-ironic-inspector-client during the upgrade. This package contains a client module for in-band inspection service, which was previously part of ironic-discoverd package. Ironic Liberty supports ironic-discoverd service, but does not support its in-tree client module. Please refer to ironic-inspector version support matrix for details on which Ironic version can work with which ironic-inspector/ironic-discoverd version.
It's also highly recommended that you switch to using ironic-inspector, which is a newer (and compatible on API level) version of the same service.
The discoverd to inspector upgrade procedure:
Install ironic-inspector on the machine where you have ironic-discoverd (usually the same as conductor).
(Recommended) update the ironic-inspector configuration file to stop using deprecated configuration options, as marked by the comments in the example.conf.
The file name is provided on command line when starting ironic-discoverd, and the previously recommended default was
/etc/ironic-discoverd/discoverd.conf
. In this case, for the sake of consistency it's recommended you move the configuration file to/etc/ironic-inspector/inspector.conf
.Shutdown ironic-discoverd, start ironic-inspector.
During upgrade of each conductor instance:
- Shutdown the conductor
- Uninstall ironic-discoverd, install python-ironic-inspector-client
- Update the conductor Kilo -> Liberty
- (Recommended) update
ironic.conf
to use[inspector]
section instead of[discoverd]
(option names are the same) - Start the conductor
Upgrading from Juno to Kilo
When upgrading a cloud from Juno to Kilo, users must ensure the Nova service is upgraded prior to upgrading the Ironic service. Additionally, users need to set a special config flag in Nova prior to upgrading to ensure the newer version of Nova is not attempting to take advantage of new Ironic features until the Ironic service has been upgraded. The steps for upgrading your Nova and Ironic services are as follows:
- Edit nova.conf and ensure force_config_drive=False is set in the [DEFAULT] group. Restart nova-compute if necessary.
- Install new Nova code, run database migrations
- Install new python-ironicclient code.
- Restart Nova services.
- Install new Ironic code, run database migrations, restart Ironic services.
- Edit nova.conf and set force_config_drive to your liking, restarting nova-compute if necessary.
Note that during the period between Nova's upgrade and Ironic's upgrades, instances can still be provisioned to nodes, however, any attempt by users to specify a config drive for an instance will cause error until Ironic's upgrade has completed.
Cleaning
A new feature in Kilo is support for the automated cleaning of nodes
between workloads to ensure the node is ready for another workload. This
can include erasing the hard drives, updating firmware, and other steps.
For more information, see automated_cleaning
.
If Ironic is configured with automated cleaning enabled (defaults to
True) and to use Neutron as the DHCP provider (also the default), you
will need to set the cleaning_network_uuid option in the Ironic
configuration file before starting the Kilo Ironic service. See CleaningNetworkSetup
for
information on how to set up the cleaning network for Ironic.