.. _config-sriov:
|
|
|
|
======
|
|
SR-IOV
|
|
======
|
|
|
|
The purpose of this page is to describe how to enable SR-IOV functionality
|
|
available in OpenStack (using OpenStack Networking). This functionality was
|
|
first introduced in the OpenStack Juno release. This page intends to serve as
|
|
a guide for how to configure OpenStack Networking and OpenStack Compute to
|
|
create SR-IOV ports.
|
|
|
|
The basics
|
|
~~~~~~~~~~
|
|
|
|
PCI-SIG Single Root I/O Virtualization and Sharing (SR-IOV) functionality is
|
|
available in OpenStack since the Juno release. The SR-IOV specification
|
|
defines a standardized mechanism to virtualize PCIe devices. This mechanism
|
|
can virtualize a single PCIe Ethernet controller to appear as multiple PCIe
|
|
devices. Each device can be directly assigned to an instance, bypassing the
|
|
hypervisor and virtual switch layer. As a result, users are able to achieve
|
|
low latency and near-line wire speed.
|
|
|
|
The following terms are used throughout this document:
|
|
|
|
.. list-table::
|
|
:header-rows: 1
|
|
:widths: 10 90
|
|
|
|
* - Term
|
|
- Definition
|
|
* - PF
|
|
- Physical Function. The physical Ethernet controller that supports
|
|
SR-IOV.
|
|
* - VF
|
|
- Virtual Function. The virtual PCIe device created from a physical
|
|
Ethernet controller.
|
|
|
|
SR-IOV agent
|
|
------------
|
|
|
|
The SR-IOV agent allows you to set the admin state of ports, configure port
|
|
security (enable and disable spoof checking), and configure QoS rate limiting
|
|
and minimum bandwidth. You must include the SR-IOV agent on each compute node
|
|
using SR-IOV ports.
|
|
|
|
.. note::
|
|
|
|
The SR-IOV agent was optional before Mitaka, and was not enabled by default
|
|
before Liberty.
|
|
|
|
.. note::
|
|
|
|
The ability to control port security and QoS rate limit settings was added
|
|
in Liberty.
|
|
|
|
Supported Ethernet controllers
|
|
------------------------------
|
|
|
|
The following manufacturers are known to work:
|
|
|
|
- Intel
|
|
- Mellanox
|
|
- QLogic
|
|
|
|
For information on **Mellanox SR-IOV Ethernet ConnectX-3/ConnectX-3 Pro cards**, see
|
|
`Mellanox: How To Configure SR-IOV VFs
|
|
<https://community.mellanox.com/docs/DOC-1484>`_.
|
|
|
|
For information on **QLogic SR-IOV Ethernet cards**, see
|
|
`User's Guide OpenStack Deployment with SR-IOV Configuration
|
|
<http://www.qlogic.com/solutions/Documents/UsersGuide_OpenStack_SR-IOV.pdf>`_.
|
|
|
|
Using SR-IOV interfaces
|
|
~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
In order to enable SR-IOV, the following steps are required:
|
|
|
|
#. Create Virtual Functions (Compute)
|
|
#. Whitelist PCI devices in nova-compute (Compute)
|
|
#. Configure neutron-server (Controller)
|
|
#. Configure nova-scheduler (Controller)
|
|
#. Enable neutron sriov-agent (Compute)
|
|
|
|
We recommend using VLAN provider networks for segregation. This way you can
|
|
combine instances without SR-IOV ports and instances with SR-IOV ports on a
|
|
single network.
|
|
|
|
.. note::
|
|
|
|
Throughout this guide, ``eth3`` is used as the PF and ``physnet2`` is used
|
|
as the provider network configured as a VLAN range. These ports may vary in
|
|
different environments.
|
|
|
|
Create Virtual Functions (Compute)
|
|
----------------------------------
|
|
|
|
Create the VFs for the network interface that will be used for SR-IOV. We use
|
|
``eth3`` as PF, which is also used as the interface for the VLAN provider
|
|
network and has access to the private networks of all machines.
|
|
|
|
.. note::
|
|
|
|
The steps detail how to create VFs using Mellanox ConnectX-4 and newer/Intel
|
|
SR-IOV Ethernet cards on an Intel system. Steps may differ for different
|
|
hardware configurations.
|
|
|
|
#. Ensure SR-IOV and VT-d are enabled in BIOS.
|
|
|
|
#. Enable IOMMU in Linux by adding ``intel_iommu=on`` to the kernel parameters,
|
|
for example, using GRUB.
|
|
|
|
#. On each compute node, create the VFs via the PCI SYS interface:
|
|
|
|
.. code-block:: console
|
|
|
|
# echo '8' > /sys/class/net/eth3/device/sriov_numvfs
|
|
|
|
.. note::
|
|
|
|
On some PCI devices, observe that when changing the amount of VFs you
|
|
receive the error ``Device or resource busy``. In this case, you must
|
|
first set ``sriov_numvfs`` to ``0``, then set it to your new value.
|
|
|
|
.. note::
|
|
|
|
A network interface could be used both for PCI passthrough, using the PF,
|
|
and SR-IOV, using the VFs. If the PF is used, the VF number stored in
|
|
the ``sriov_numvfs`` file is lost. If the PF is attached again to the
|
|
operating system, the number of VFs assigned to this interface will be
|
|
zero. To keep the number of VFs always assigned to this interface,
|
|
modify the interfaces configuration file adding an ``ifup`` script
|
|
command.
|
|
|
|
On Ubuntu, modify the ``/etc/network/interfaces`` file:
|
|
|
|
.. code-block:: ini
|
|
|
|
auto eth3
|
|
iface eth3 inet dhcp
|
|
pre-up echo '4' > /sys/class/net/eth3/device/sriov_numvfs
|
|
|
|
On RHEL and derivatives, modify the ``/sbin/ifup-local`` file:
|
|
|
|
.. code-block:: bash
|
|
|
|
#!/bin/sh
|
|
if [[ "$1" == "eth3" ]]
|
|
then
|
|
echo '4' > /sys/class/net/eth3/device/sriov_numvfs
|
|
fi
|
|
|
|
.. warning::
|
|
|
|
Alternatively, you can create VFs by passing the ``max_vfs`` to the
|
|
kernel module of your network interface. However, the ``max_vfs``
|
|
parameter has been deprecated, so the PCI SYS interface is the preferred
|
|
method.
|
|
|
|
You can determine the maximum number of VFs a PF can support:
|
|
|
|
.. code-block:: console
|
|
|
|
# cat /sys/class/net/eth3/device/sriov_totalvfs
|
|
63
|
|
|
|
#. Verify that the VFs have been created and are in ``up`` state. For example:
|
|
|
|
.. code-block:: console
|
|
|
|
# lspci | grep Ethernet
|
|
82:00.0 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
|
|
82:00.1 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
|
|
82:10.0 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
82:10.2 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
82:10.4 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
82:10.6 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
82:11.0 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
82:11.2 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
82:11.4 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
82:11.6 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01)
|
|
|
|
.. code-block:: console
|
|
|
|
# ip link show eth3
|
|
8: eth3: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT qlen 1000
|
|
link/ether a0:36:9f:8f:3f:b8 brd ff:ff:ff:ff:ff:ff
|
|
vf 0 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
vf 1 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
vf 2 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
vf 3 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
vf 4 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
vf 5 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
vf 6 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
vf 7 MAC 00:00:00:00:00:00, spoof checking on, link-state auto
|
|
|
|
If the interfaces are down, set them to ``up`` before launching a guest,
|
|
otherwise the instance will fail to spawn:
|
|
|
|
.. code-block:: console
|
|
|
|
# ip link set eth3 up
|
|
|
|
#. Persist created VFs on reboot:
|
|
|
|
.. code-block:: console
|
|
|
|
# echo "echo '7' > /sys/class/net/eth3/device/sriov_numvfs" >> /etc/rc.local
|
|
|
|
.. note::
|
|
|
|
The suggested way of making PCI SYS settings persistent is through
|
|
the ``sysfsutils`` tool. However, this is not available by default on
|
|
many major distributions.
|
|
|
|
Whitelist PCI devices nova-compute (Compute)
|
|
--------------------------------------------
|
|
|
|
#. Configure which PCI devices the ``nova-compute`` service may use. Edit
|
|
the ``nova.conf`` file:
|
|
|
|
.. code-block:: ini
|
|
|
|
[pci]
|
|
passthrough_whitelist = { "devname": "eth3", "physical_network": "physnet2"}
|
|
|
|
This tells the Compute service that all VFs belonging to ``eth3`` are
|
|
allowed to be passed through to instances and belong to the provider network
|
|
``physnet2``.
|
|
|
|
Alternatively the ``[pci] passthrough_whitelist`` parameter also supports
|
|
whitelisting by:
|
|
|
|
- PCI address: The address uses the same syntax as in ``lspci`` and an
|
|
asterisk (``*``) can be used to match anything.
|
|
|
|
.. code-block:: ini
|
|
|
|
[pci]
|
|
passthrough_whitelist = { "address": "[[[[<domain>]:]<bus>]:][<slot>][.[<function>]]", "physical_network": "physnet2" }
|
|
|
|
For example, to match any domain, bus ``0a``, slot ``00``, and all
|
|
functions:
|
|
|
|
.. code-block:: ini
|
|
|
|
[pci]
|
|
passthrough_whitelist = { "address": "*:0a:00.*", "physical_network": "physnet2" }
|
|
|
|
- PCI ``vendor_id`` and ``product_id`` as displayed by the Linux utility
|
|
``lspci``.
|
|
|
|
.. code-block:: ini
|
|
|
|
[pci]
|
|
passthrough_whitelist = { "vendor_id": "<id>", "product_id": "<id>", "physical_network": "physnet2" }
|
|
|
|
If the device defined by the PCI address or ``devname`` corresponds to an
|
|
SR-IOV PF, all VFs under the PF will match the entry. Multiple
|
|
``[pci] passthrough_whitelist`` entries per host are supported.
|
|
|
|
In order to enable SR-IOV to request "trusted mode", the
|
|
``[pci] passthrough_whitelist`` parameter also supports a ``trusted``
|
|
tag.
|
|
|
|
.. note::
|
|
|
|
This capability is only supported starting with version 18.0.0
|
|
(Rocky) release of the compute service configured to use the
|
|
libvirt driver.
|
|
|
|
.. important::
|
|
|
|
There are security implications of enabling trusted ports. The
|
|
trusted VFs can be set into VF promiscuous mode which will
|
|
enable it to receive unmatched and multicast traffic sent to the
|
|
physical function.
|
|
|
|
For example, to allow users to request SR-IOV devices with trusted
|
|
capabilities on device ``eth3``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[pci]
|
|
passthrough_whitelist = { "devname": "eth3", "physical_network": "physnet2", "trusted":"true" }
|
|
|
|
The ports will have to be created with a binding profile to match the
|
|
``trusted`` tag, see `Launching instances with SR-IOV ports`_.
|
|
|
|
#. Restart the ``nova-compute`` service for the changes to go into effect.
|
|
|
|
.. _configure_sriov_neutron_server:
|
|
|
|
Configure neutron-server (Controller)
|
|
-------------------------------------
|
|
|
|
#. Add ``sriovnicswitch`` as mechanism driver. Edit the ``ml2_conf.ini`` file
|
|
on each controller:
|
|
|
|
.. code-block:: ini
|
|
|
|
[ml2]
|
|
mechanism_drivers = openvswitch,sriovnicswitch
|
|
|
|
#. Ensure your physnet is configured for the chosen network type. Edit the
|
|
``ml2_conf.ini`` file on each controller:
|
|
|
|
.. code-block:: ini
|
|
|
|
[ml2_type_vlan]
|
|
network_vlan_ranges = physnet2
|
|
|
|
#. Add the ``plugin.ini`` file as a parameter to the ``neutron-server``
|
|
service. Edit the appropriate initialization script to configure the
|
|
``neutron-server`` service to load the plugin configuration file:
|
|
|
|
.. code-block:: bash
|
|
|
|
--config-file /etc/neutron/neutron.conf
|
|
--config-file /etc/neutron/plugin.ini
|
|
|
|
#. Restart the ``neutron-server`` service.
|
|
|
|
Configure nova-scheduler (Controller)
|
|
-------------------------------------
|
|
|
|
#. On every controller node running the ``nova-scheduler`` service, add
|
|
``PciPassthroughFilter`` to ``[filter_scheduler] enabled_filters`` to enable
|
|
this filter. Ensure ``[filter_scheduler] available_filters`` is set to the
|
|
default of ``nova.scheduler.filters.all_filters``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[filter_scheduler]
|
|
enabled_filters = RetryFilter, AvailabilityZoneFilter, ComputeFilter, ComputeCapabilitiesFilter, ImagePropertiesFilter, ServerGroupAntiAffinityFilter, ServerGroupAffinityFilter, PciPassthroughFilter
|
|
available_filters = nova.scheduler.filters.all_filters
|
|
|
|
#. Restart the ``nova-scheduler`` service.
|
|
|
|
Enable neutron-sriov-nic-agent (Compute)
|
|
----------------------------------------
|
|
|
|
#. Install the SR-IOV agent, if necessary.
|
|
|
|
#. Edit the ``sriov_agent.ini`` file on each compute node. For example:
|
|
|
|
.. code-block:: ini
|
|
|
|
[securitygroup]
|
|
firewall_driver = neutron.agent.firewall.NoopFirewallDriver
|
|
|
|
[sriov_nic]
|
|
physical_device_mappings = physnet2:eth3
|
|
exclude_devices =
|
|
|
|
.. note::
|
|
|
|
The ``physical_device_mappings`` parameter is not limited to be a 1-1
|
|
mapping between physical networks and NICs. This enables you to map the
|
|
same physical network to more than one NIC. For example, if ``physnet2``
|
|
is connected to ``eth3`` and ``eth4``, then
|
|
``physnet2:eth3,physnet2:eth4`` is a valid option.
|
|
|
|
The ``exclude_devices`` parameter is empty, therefore, all the VFs
|
|
associated with eth3 may be configured by the agent. To exclude specific
|
|
VFs, add them to the ``exclude_devices`` parameter as follows:
|
|
|
|
.. code-block:: ini
|
|
|
|
exclude_devices = eth1:0000:07:00.2;0000:07:00.3,eth2:0000:05:00.1;0000:05:00.2
|
|
|
|
#. Ensure the SR-IOV agent runs successfully:
|
|
|
|
.. code-block:: console
|
|
|
|
# neutron-sriov-nic-agent \
|
|
--config-file /etc/neutron/neutron.conf \
|
|
--config-file /etc/neutron/plugins/ml2/sriov_agent.ini
|
|
|
|
#. Enable the neutron SR-IOV agent service.
|
|
|
|
If installing from source, you must configure a daemon file for the init
|
|
system manually.
|
|
|
|
(Optional) FDB L2 agent extension
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
Forwarding DataBase (FDB) population is an L2 agent extension to OVS agent or
|
|
Linux bridge. Its objective is to update the FDB table for existing instance
|
|
using normal port. This enables communication between SR-IOV instances and
|
|
normal instances. The use cases of the FDB population extension are:
|
|
|
|
* Direct port and normal port instances reside on the same compute node.
|
|
|
|
* Direct port instance that uses floating IP address and network node
|
|
are located on the same host.
|
|
|
|
For additional information describing the problem, refer to:
|
|
`Virtual switching technologies and Linux bridge.
|
|
<https://events.static.linuxfound.org/sites/events/files/slides/LinuxConJapan2014_makita_0.pdf>`_
|
|
|
|
#. Edit the ``ovs_agent.ini`` or ``linuxbridge_agent.ini`` file on each compute
|
|
node. For example:
|
|
|
|
.. code-block:: console
|
|
|
|
[agent]
|
|
extensions = fdb
|
|
|
|
#. Add the FDB section and the ``shared_physical_device_mappings`` parameter.
|
|
This parameter maps each physical port to its physical network name. Each
|
|
physical network can be mapped to several ports:
|
|
|
|
.. code-block:: console
|
|
|
|
[FDB]
|
|
shared_physical_device_mappings = physnet1:p1p1, physnet1:p1p2
|
|
|
|
Launching instances with SR-IOV ports
|
|
-------------------------------------
|
|
|
|
Once configuration is complete, you can launch instances with SR-IOV ports.
|
|
|
|
#. If it does not already exist, create a network and subnet for the chosen
|
|
physnet. This is the network to which SR-IOV ports will be attached. For
|
|
example:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack network create --provider-physical-network physnet2 \
|
|
--provider-network-type vlan --provider-segment 1000 \
|
|
sriov-net
|
|
|
|
$ openstack subnet create --network sriov-net \
|
|
--subnet-pool shared-default-subnetpool-v4 \
|
|
sriov-subnet
|
|
|
|
#. Get the ``id`` of the network where you want the SR-IOV port to be created:
|
|
|
|
.. code-block:: console
|
|
|
|
$ net_id=$(openstack network show sriov-net -c id -f value)
|
|
|
|
#. Create the SR-IOV port. ``vnic-type=direct`` is used here, but other options
|
|
include ``normal``, ``direct-physical``, and ``macvtap``:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack port create --network $net_id --vnic-type direct \
|
|
sriov-port
|
|
|
|
Alternatively, to request that the SR-IOV port accept trusted capabilities,
|
|
the binding profile should be enhanced with the ``trusted`` tag.
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack port create --network $net_id --vnic-type direct \
|
|
--binding-profile trusted=true \
|
|
sriov-port
|
|
|
|
#. Get the ``id`` of the created port:
|
|
|
|
.. code-block:: console
|
|
|
|
$ port_id=$(openstack port show sriov-port -c id -f value)
|
|
|
|
#. Create the instance. Specify the SR-IOV port created in step two for the
|
|
NIC:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack server create --flavor m1.large --image ubuntu_18.04 \
|
|
--nic port-id=$port_id \
|
|
test-sriov
|
|
|
|
.. note::
|
|
|
|
There are two ways to attach VFs to an instance. You can create an SR-IOV
|
|
port or use the ``pci_alias`` in the Compute service. For more
|
|
information about using ``pci_alias``, refer to `nova-api
|
|
configuration`__.
|
|
|
|
__ https://docs.openstack.org/nova/latest/admin/pci-passthrough.html#configure-nova-api-controller
|
|
|
|
SR-IOV with InfiniBand
|
|
~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The support for SR-IOV with InfiniBand allows a Virtual PCI device (VF) to
|
|
be directly mapped to the guest, allowing higher performance and advanced
|
|
features such as RDMA (remote direct memory access). To use this feature,
|
|
you must:
|
|
|
|
#. Use InfiniBand enabled network adapters.
|
|
|
|
#. Run InfiniBand subnet managers to enable InfiniBand fabric.
|
|
|
|
All InfiniBand networks must have a subnet manager running for the network
|
|
to function. This is true even when doing a simple network of two
|
|
machines with no switch and the cards are plugged in back-to-back. A
|
|
subnet manager is required for the link on the cards to come up.
|
|
It is possible to have more than one subnet manager. In this case, one
|
|
of them will act as the master, and any other will act as a slave that
|
|
will take over when the master subnet manager fails.
|
|
|
|
#. Install the ``ebrctl`` utility on the compute nodes.
|
|
|
|
Check that ``ebrctl`` is listed somewhere in ``/etc/nova/rootwrap.d/*``:
|
|
|
|
.. code-block:: console
|
|
|
|
$ grep 'ebrctl' /etc/nova/rootwrap.d/*
|
|
|
|
If ``ebrctl`` does not appear in any of the rootwrap files, add this to the
|
|
``/etc/nova/rootwrap.d/compute.filters`` file in the ``[Filters]`` section.
|
|
|
|
.. code-block:: none
|
|
|
|
[Filters]
|
|
ebrctl: CommandFilter, ebrctl, root
|
|
|
|
Known limitations
|
|
~~~~~~~~~~~~~~~~~
|
|
|
|
* When using Quality of Service (QoS), ``max_burst_kbps`` (burst over
|
|
``max_kbps``) is not supported. In addition, ``max_kbps`` is rounded to
|
|
Mbps.
|
|
* Security groups are not supported when using SR-IOV, thus, the firewall
|
|
driver must be disabled. This can be done in the ``neutron.conf`` file.
|
|
|
|
.. code-block:: ini
|
|
|
|
[securitygroup]
|
|
firewall_driver = neutron.agent.firewall.NoopFirewallDriver
|
|
|
|
* SR-IOV is not integrated into the OpenStack Dashboard (horizon). Users must
|
|
use the CLI or API to configure SR-IOV interfaces.
|
|
* Live migration is not supported for instances with SR-IOV ports.
|
|
|
|
.. note::
|
|
|
|
SR-IOV features may require a specific NIC driver version, depending on the vendor.
|
|
Intel NICs, for example, require ixgbe version 4.4.6 or greater, and ixgbevf version
|
|
3.2.2 or greater.
|
|
* Attaching SR-IOV ports to existing servers is not currently supported, see
|
|
`bug 1708433 <https://bugs.launchpad.net/nova/+bug/1708433>`_ for details.
|