3f5a14dc10
Adds Debian in the Ubuntu section for restarting the Cinder service when configuring Cinder to work with Ceilometer. Change-Id: I3ad49ad4bd7bb85584f3a32f493c1500b1427203
1.6 KiB
1.6 KiB
Enable Block Storage meters
Telemetry uses notifications to collect Block Storage service meters. Perform these steps on the controller and Block Storage nodes.
Note
Your environment must include the Block Storage service.
Configure Cinder to use Telemetry
Edit the /etc/cinder/cinder.conf
file and complete the
following actions:
In the
[DEFAULT]
section, configure notifications:[DEFAULT] ... notification_driver = messagingv2
Finalize installation
obs or rdo
Restart the Block Storage services on the controller node:
# systemctl restart openstack-cinder-api.service openstack-cinder-scheduler.service
Restart the Block Storage services on the storage nodes:
# systemctl restart openstack-cinder-volume.service
ubuntu or debian
Restart the Block Storage services on the controller node:
# service cinder-api restart # service cinder-scheduler restart
Restart the Block Storage services on the storage nodes:
# service cinder-volume restart
- Use the
cinder-volume-usage-audit
command on Block Storage nodes to retrieve meters on demand. For more information, see the Cloud Administrator Guide <http://docs.openstack.org/admin-guide-cloud/ telemetry-data-collection.html#block-storage-audit-script-setup-to-get- notifications>__.