Sofer Athlan-Guyot fb78213782 Put service stop at step1 and quiesce at step2.
In the previous release[1], the services were stopped before the
pacemaker services, so that they get a chance to send last message to
the database/rabbitmq queue:

Let's do the upgrade in the same order.

[1] https://github.com/openstack/tripleo-heat-templates/blob/stable/newton/extraconfig/tasks/major_upgrade_controller_pacemaker_2.sh#L13-L71

Change-Id: I1c4045e8b9167396c9dfa4da99973102f1af1218
2017-02-28 19:20:13 +01:00

31 lines
932 B
YAML

heat_template_version: ocata
description: >
OpenStack Glance Registry service, disabled since ocata
parameters:
ServiceNetMap:
default: {}
description: Mapping of service_name -> network name. Typically set
via parameter_defaults in the resource registry. This
mapping overrides those in ServiceNetMapDefaults.
type: json
DefaultPasswords:
default: {}
type: json
EndpointMap:
default: {}
description: Mapping of service endpoint -> protocol. Typically set
via parameter_defaults in the resource registry.
type: json
outputs:
role_data:
description: Role data for the disabled Glance Registry role.
value:
service_name: glance_registry
upgrade_tasks:
- name: Stop and disable glance_registry service on upgrade
tags: step1
service: name=openstack-glance-registry state=stopped enabled=no