Go to file
Eric MacDonald 78694d4ff9 Reduce sw-patch init script controller ping timeout for simplex systems
The DELAY_SEC variable in the sw-patch init script controls how
long the service waits for an active controller to respond before
proceeding. The default is 120 seconds.

On simplex (AIO-SX) systems, this wait always times out since there is
no active 'controller', resulting in an unnecessary 2-minute delay
during reboot or unlock operations.

This update significantly reduces the timeout delay on simplex systems,
improving boot and unlock responsiveness without affecting duplex
systems.

Test Plan:

PASS: Verify build and install on AIO-SX
PASS: Verify build and install on AIO-DX
PASS: Verify unlock of AIO-SX is not delayed by sw-patch timeout
PASS: Verify sw-patch times out after ~10s with no controller ping (SX)
PASS: Verify sw-patch still uses 120s timeout on AIO-DX

Closes-Bug: 2111941
Change-Id: I46d33e87897e2ae67011241f9f83ae0d153f19ce
Signed-off-by: Eric MacDonald <eric.macdonald@windriver.com>